SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Nigro A.) srt2:(2005-2009)"

Sökning: WFRF:(Nigro A.) > (2005-2009)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aaron, F. D., et al. (författare)
  • Multi-leptons with high transverse momentum at HERA
  • 2009
  • Ingår i: Journal of High Energy Physics. - : Springer Science and Business Media LLC. - 1029-8479. ; :10
  • Tidskriftsartikel (refereegranskat)abstract
    • Events with at least two high transverse momentum leptons (electrons or muons) are studied using the H1 and ZEUS detectors at HERA with an integrated luminosity of 0.94 fb(-1). The observed numbers of events are in general agreement with the Standard Model predictions. Seven di- and tri-lepton events are observed in e(+)p collision data with a scalar sum of the lepton transverse momenta above 100 GeV while 1.94 +/- 0.17 events are expected. Such events are not observed in e(-)p collisions for which 1.19 +/- 0.12 are predicted. Total visible and differential di-electron and di-muon photoproduction cross sections are extracted in a restricted phase space dominated by photon-photon collisions.
  •  
2.
  • Aguilar, J. A., et al. (författare)
  • First results of the instrumentation line for the deep-sea ANTARES neutrino telescope
  • 2006
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 26:4-5, s. 314-324
  • Tidskriftsartikel (refereegranskat)abstract
    • In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
  •  
3.
  • Aguilar, J. A., et al. (författare)
  • The data acquisition system for the ANTARES neutrino telescope
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 107-116
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described. (c) 2006 Elsevier B.V. All rights reserved.
  •  
4.
  • Aguilar, J A, et al. (författare)
  • Transmission of light in deep sea water at the site of the ANTARES neutrino telescope
  • 2005
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 23:1, s. 131-155
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope is a large photomultiplier array designed to detect neutrino-induced upward-going muons by their Cherenkov radiation. Understanding the absorption and scattering of light in the deep Mediterranean is fundamental to optimising the design and performance of the detector. This paper presents measurements of blue and UV light transmission at the ANTARES site taken between 1997 and 2000. The derived values for the scattering length and the angular distribution of particulate scattering were found to be highly correlated, and results are therefore presented in terms of an absorption length;,ab, and an effective scattering length lambda(sct)(eff). The values for blue (UV) light are found to be lambda(abs) similar or equal to 60(26) m, lambda(sct)(eff similar or equal to) 265(122) m, with significant (similar to15%) time variability. Finally, the results of ANTARES simulations showing the effect of these water properties on the anticipated performance of the detector are presented. (C) 2004 Elsevier B.V. All rights reserved.
  •  
5.
  • Aguilar, J A, et al. (författare)
  • Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 555:1-2, s. 132-141
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a three-dimensional matrix of 900 large area photomultiplier tubes housed in pressure-resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the photomultiplier tube chosen for ANTARES. (c) 2005 Elsevier B.V. All rights reserved.
  •  
6.
  • Panaccione, G., et al. (författare)
  • Analysis of surface-bulk screening competition in the electron-doped Nd2-xCexCuO4 cuprate using x-ray photoemission spectroscopy
  • 2008
  • Ingår i: Physical Review B. Condensed Matter and Materials Physics. - 1098-0121 .- 1550-235X. ; 77:12
  • Tidskriftsartikel (refereegranskat)abstract
    • We report core level and valence band photoemission results obtained for Nd2-xCexCuO4 (x = 0.15) single crystals and films by using both soft and hard x rays, hence, with tunable depth sensitivity. When using hard x rays only, we observe distinct and energy separated structures in the main 2p(5)3d(9)L peak of Cu 2p(3/2) and 2p(1/2) core levels, including the well screened features located at the high kinetic energy side, which were recently reported by Taguchi et al. [Phys. Rev. Lett. 95, 177002 (2005)]. By varying the photoelectron takeoff angle, we analyze the difference in the screening properties between surface and bulk, and we demonstrate the depth dependence of the electronic properties by following the evolution of the bulk-related peak. The possible influence of the surface conditions on the Cu 2p spectral features is also discussed.
  •  
7.
  • Balgobind, Brian V, et al. (författare)
  • Novel prognostic subgroups in childhood 11q23/MLL-rearranged acute myeloid leukemia : results of an international retrospective study.
  • 2009
  • Ingår i: Blood. - : American Society of Hematology. - 0006-4971 .- 1528-0020. ; 114:12, s. 2489-2496
  • Tidskriftsartikel (refereegranskat)abstract
    • Translocations involving chromosome 11q23 frequently occur in pediatric acute myeloid leukemia (AML) and are associated with poor prognosis. In most cases, the MLL gene is involved, and more than 50 translocation partners have been described. Clinical outcome data of the 11q23-rearranged subgroups are scarce because most 11q23 series are too small for meaningful analysis of subgroups, although some studies suggest that patients with t(9;11)(p22;q23) have a more favorable prognosis. We retrospectively collected outcome data of 756 children with 11q23- or MLL-rearranged AML from 11 collaborative groups to identify differences in outcome based on translocation partners. All karyotypes were centrally reviewed before assigning patients to subgroups. The event-free survival of 11q23/MLL-rearranged pediatric AML at 5 years from diagnosis was 44% (+/- 5%), with large differences across subgroups (11% +/- 5% to 92% +/- 5%). Multivariate analysis identified the following subgroups as independent prognostic predictors: t(1;11)(q21;q23) (hazard ratio [HR] = 0.1, P = .004); t(6;11)(q27;q23) (HR = 2.2, P < .001); t(10;11)(p12;q23) (HR = 1.5, P = .005); and t(10;11)(p11.2;q23) (HR = 2.5, P = .005). We could not confirm the favorable prognosis of the t(9;11)(p22;q23) subgroup. We identified large differences in outcome within 11q23/MLL-rearranged pediatric AML and novel subgroups based on translocation partners that independently predict clinical outcome. Screening for these translocation partners is needed for accurate treatment stratification at diagnosis.
  •  
8.
  • Del Barga, I., et al. (författare)
  • Effects of algal extracts (Polysiphonia fucoides) on rainbow trout (Oncorhynchus mykiss): A biomarker approach
  • 2006
  • Ingår i: Marine Environmental Research. - : Elsevier BV. - 0141-1136. ; 62:Supplement 1
  • Tidskriftsartikel (refereegranskat)abstract
    • The genotoxicity of algal extracts (Polysiphonia fucoides) was investigated in erythrocytes of rainbow trout (Oncorhynchus mykiss). Trout were exposed to 0.5% of the algal extract for 7 days. Comet assay (alkaline and neutral versions) and Micronucleus test were used to assess DNA damage, and Diffusion Assay to detect apoptotic cells. EROD activities and oxidative stress parameters in rainbow trout liver were also measured. A significant induction of DNA single strand breaks comparable to the ones induced by the in vivo exposure to 20 mg/kg B[a]P was observed at the end of the treatment, while increases of double strand breaks and apoptotic cells were not observed. The absence of activation of antioxidant responses seems to underline a mechanism of action of the genotoxic algal extract which does not involve oxidative stress.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy