SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Nyholm Tufve) srt2:(2015-2019)"

Sökning: WFRF:(Nyholm Tufve) > (2015-2019)

  • Resultat 1-10 av 52
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Adjeiwaah, Mary, 1980-, et al. (författare)
  • Dosimetric Impact of MRI Distortions : A Study on Head and Neck Cancers
  • 2019
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier. - 0360-3016 .- 1879-355X. ; 103:4, s. 994-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate the effect of magnetic resonance (MR) imaging (MRI) geometric distortions on head and neck radiation therapy treatment planning (RTP) for an MRI-only RTP. We also assessed the potential benefits of patient-specific shimming to reduce the magnitude of MR distortions for a 3-T scanner.Methods and Materials: Using an in-house Matlab algorithm, shimming within entire imaging volumes and user-defined regions of interest were simulated. We deformed 21 patient computed tomography (CT) images with MR distortion fields (gradient nonlinearity and patient-induced susceptibility effects) to create distorted CT (dCT) images using bandwidths of 122 and 488 Hz/mm at 3 T. Field parameters from volumetric modulated arc therapy plans initially optimized on dCT data sets were transferred to CT data to compute a new plan. Both plans were compared to determine the impact of distortions on dose distributions.Results: Shimming across entire patient volumes decreased the percentage of voxels with distortions of more than 2 mm from 15.4% to 2.0%. Using the user-defined region of interest (ROI) shimming strategy, (here the Planning target volume (PTV) was the chosen ROI volume) led to increased geometric for volumes outside the PTV, as such voxels within the spinal cord with geometric shifts above 2 mm increased from 11.5% to 32.3%. The worst phantom-measured residual system distortions after 3-dimensional gradient nonlinearity correction within a radial distance of 200 mm from the isocenter was 2.17 mm. For all patients, voxels with distortion shifts of more than 2 mm resulting from patient-induced susceptibility effects were 15.4% and 0.0% using bandwidths of 122 Hz/mm and 488 Hz/mm at 3 T. Dose differences between dCT and CT treatment plans in D-50 at the planning target volume were 0.4% +/- 0.6% and 0.3% +/- 0.5% at 122 and 488 Hz/mm, respectively.Conclusions: The overall effect of MRI geometric distortions on data used for RTP was minimal. Shimming over entire imaging volumes decreased distortions, but user-defined subvolume shimming introduced significant errors in nearby organs and should probably be avoided.
  •  
3.
  • Adjeiwaah, Mary, 1980- (författare)
  • Quality assurance for magnetic resonance imaging (MRI) in radiotherapy
  • 2017
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Magnetic resonance imaging (MRI) utilizes the magnetic properties of tissues to generate image-forming signals. MRI has exquisite soft-tissue contrast and since tumors are mainly soft-tissues, it offers improved delineation of the target volume and nearby organs at risk. The proposed Magnetic Resonance-only Radiotherapy (MR-only RT) work flow allows for the use of MRI as the sole imaging modality in the radiotherapy (RT) treatment planning of cancer. There are, however, issues with geometric distortions inherent with MR image acquisition processes. These distortions result from imperfections in the main magnetic field, nonlinear gradients, as well as field disturbances introduced by the imaged object. In this thesis, we quantified the effect of system related and patient-induced susceptibility geometric distortions on dose distributions for prostate as well as head and neck cancers. Methods to mitigate these distortions were also studied.In Study I, mean worst system related residual distortions of 3.19, 2.52 and 2.08 mm at bandwidths (BW) of 122, 244 and 488 Hz/pixel up to a radial distance of 25 cm from a 3T PET/MR scanner was measured with a large field of view (FoV) phantom. Subsequently, we estimated maximum shifts of 5.8, 2.9 and 1.5 mm due to patient-induced susceptibility distortions. VMAT-optimized treatment plans initially performed on distorted CT (dCT) images and recalculated on real CT datasets resulted in a dose difference of less than 0.5%. The magnetic susceptibility differences at tissue-metallic,-air and -bone interfaces result in local B0 magnetic field inhomogeneities. The distortion shifts caused by these field inhomogeneities can be reduced by shimming.  Study II aimed to investigate the use of shimming to improve the homogeneity of local  B0 magnetic field which will be beneficial for radiotherapy applications. A shimming simulation based on spherical harmonics modeling was developed. The spinal cord, an organ at risk is surrounded by bone and in close proximity to the lungs may have high susceptibility differences. In this region, mean pixel shifts caused by local B0 field inhomogeneities were reduced from 3.47±1.22 mm to 1.35±0.44 mm and 0.99±0.30 mm using first and second order shimming respectively. This was for a bandwidth of 122 Hz/pixel and an in-plane voxel size of 1×1 mm2.  Also examined in Study II as in Study I was the dosimetric effect of geometric distortions on 21 Head and Neck cancer treatment plans. The dose difference in D50 at the PTV between distorted CT and real CT plans was less than 1.0%.In conclusion, the effect of MR geometric distortions on dose plans was small. Generally, we found patient-induced susceptibility distortions were larger compared with residual system distortions at all delineated structures except the external contour. This information will be relevant when setting margins for treatment volumes and organs at risk.  The current practice of characterizing MR geometric distortions utilizing spatial accuracy phantoms alone may not be enough for an MR-only radiotherapy workflow. Therefore, measures to mitigate patient-induced susceptibility effects in clinical practice such as patient-specific correction algorithms are needed to complement existing distortion reduction methods such as high acquisition bandwidth and shimming.
  •  
4.
  • Adjeiwaah, Mary, 1980- (författare)
  • Quality assurance for magnetic resonance imaging (MRI) in radiotherapy
  • 2019
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The use of Magnetic Resonance Imaging (MRI) in the radiotherapy (RT) treatment planning workflow is increasing. MRI offers superior soft-tissue contrast compared to Computed Tomography (CT) and therefore improves the accuracy in target volume definitions. There are, however concerns with inherent geometric distortions from system- (gradient nonlinearities and main magnetic field inhomogeneities) and patient-related sources (magnetic susceptibility effect and chemical shift). The lack of clearly defined quality assurance (QA) procedures has also raised questions on the ability of current QA protocols to detect common image quality degradations under radiotherapy settings. To fully implement and take advantage of the benefits of MRI in radiotherapy, these concerns need to be addressed.In Papers I and II, the dosimetric impact of MR distortions was investigated. Patient CTs (CT) were deformed with MR distortion vector fields (from the residual system distortions after correcting for gradient nonlinearities and patient-induced susceptibility distortions) to create distorted CT (dCT) images. Field parameters from volumetric modulated arc therapy (VMAT) treatment plans initially optimized on dCT data sets were transferred to CT data to compute new treatment plans. Data from 19 prostate and 21 head and neck patients were used for the treatment planning. The dCT and CT treatment plans were compared to determine the impact of distortions on dose distributions. No clinically relevant dose differences between distorted CT and original CT treatment plans were found. Mean dose differences were < 1.0% and < 0.5% at the planning target volume (PTV) for the head and neck, and prostate treatment plans, respectively. Strategies to reduce geometric distortions were also evaluated in Papers I and II. Using the vendor-supplied gradient non-linearity correction algorithm reduced overall distortions to less than half of the original value. A high acquisition bandwidth of 488 Hz/pixel (Paper I) and 488 Hz/mm (Paper II) kept the mean geometric distortions at the delineated structures below 1 mm. Furthermore, a patient-specific active shimming method implemented in Paper II significantly reduced the number of voxels with distortion shifts > 2 mm from 15.4% to 2.0%.B0 maps from patient-induced magnetic field inhomogeneities obtained through direct measurements and by simulations that used MR-generated synthetic CT (sCT) data were compared in Paper III. The validation showed excellent agreement between the simulated and measured B0 maps.In Paper IV, the ability of current QA methods to detect common MR image quality degradations under radiotherapy settings were investigated. By evaluating key image quality parameters, the QA protocols were found to be sensitive to some of the introduced degradations. However, image quality issues such as those caused by RF coil failures could not be adequately detected.In conclusion, this work has shown the feasibility of using MRI data for radiotherapy treatment planning as distortions resulted in a dose difference of less than 1% between distorted and undistorted images. The simulation software can be used to produce accurate B0 maps, which could then be used as the basis for the effective correction of patient-induced field inhomogeneity distortions and for the QA verification of sCT data. Furthermore, the analysis of the strengths and weaknesses in current QA tools for MRI in RT contribute to finding better methods to efficiently identify image quality errors.
  •  
5.
  • Adjeiwaah, Mary, et al. (författare)
  • Quantifying the Effect of 3T Magnetic Resonance Imaging Residual System Distortions and Patient-Induced Susceptibility Distortions on Radiation Therapy Treatment Planning for Prostate Cancer
  • 2018
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier. - 0360-3016 .- 1879-355X. ; 100:2, s. 317-324
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the effect of magnetic resonance system- and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers.Methods and Materials: Combined displacement fields from the residual system and patient-induced susceptibility distortions were used to distort 17 prostate patient CT images. VMAT dose plans were initially optimized on distorted CT images and the plan parameters transferred to the original patient CT images to calculate a new dose distribution.Results: Maximum residual mean distortions of 3.19 mm at a radial distance of 25 cm and maximum mean patient-induced susceptibility shifts of 5.8 mm were found using the lowest bandwidth of 122 Hz per pixel. There was a dose difference of <0.5% between distorted and undistorted treatment plans. The 90% confidence intervals of the mean difference between the dCT and CT treatment plans were all within an equivalence interval of (−0.5, 0.5) for all investigated plan quality measures.Conclusions: Patient-induced susceptibility distortions at high field strengths in closed bore magnetic resonance scanners are larger than residual system distortions after using vendor-supplied 3-dimensional correction for the delineated regions studied. However, errors in dose due to disturbed patient outline and shifts caused by patient-induced susceptibility effects are below 0.5%.
  •  
6.
  • Björeland, Ulrika, et al. (författare)
  • Inter-fraction movements of the prostate and pelvic lymph nodes during IGRT
  • 2018
  • Ingår i: Journal of radiation oncology. - : Springer. - 1948-7894 .- 1948-7908. ; 7:4, s. 357-366
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectivities: The aim of this study was to evaluate inter-fraction movements of lymph node regions that are commonly included in the pelvic clinical target volume (CTV) for high-risk prostate cancer patients. We also aimed to evaluate if the movements affect the planning target volumes. Methods: Ten prostate cancer patients were included. The patients underwent six MRI scans, from treatment planning to near end of treatment. The CTV movements were analyzed with deformable registration technique with the CTV divided into sections. The validity of the deformable registration was assessed by comparing the results for individual lymph nodes that were possible to identify in all scans. Results: Using repetitive MRI, measurements showed that areas inside the CTV (lymph nodes) in some extreme cases were as mobile as the prostate and not fixed to the bones. The lymph node volumes closest to the prostate did not tend to follow the prostate motion. The more cranial lymph node volumes moved less, but still independently, and they were not necessarily fixed to the pelvic bones. In 95% of the cases, the lymph node motion in the R-L direction was 2-4mm, in the A-P direction 2-7mm, and in the C-C direction 2-5mm depending on the CTV section. Conclusion: Lymph nodes and prostate were most mobile in the A-P direction, followed by the C-C and R-L directions. This movement should be taken into account when deciding the margins for the planning target volumes (PTV).
  •  
7.
  • Brynolfsson, Patrik, 1981- (författare)
  • Applications of statistical methods in quantitative magnetic resonance imaging
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Magnetic resonance imaging, MRI, offers a vast range of imaging methods that can be employed in the characterization of tumors. MRI is generally used in a qualitative way, where radiologists interpret the images for e.g. diagnosis, follow ups, or assessment of treatment response. In the past decade, there has been an increasing interest for quantitative imaging, which give repeatable measurements of the anatomy. Quantitative imaging allows for objective analysis of the images, which are grounded in physical properties of the underlying tissues. The aim of this thesis was to improve quantitative measurements of Dynamic contrast enhanced MRI (DCE-MRI), and the texture analysis of diffusion weighted MRI (DW-MRI).DCE-MRI measures perfusion, which is the delivery of blood, oxygen and nutrients to the tissues. The exam involves continuously imaging the region of interest, e.g. a tumor, while injecting a contrast agent (CA) in the blood stream. By analyzing how fast and how much CA leaks out into the tissues, the cell density and the permeability of the capillaries can be estimated. Tumors often have an irregular and broken vasculature, and DCE-MRI can aid in tumor grading or treatment assessment. One step is crucial when performing DCE-MRI analysis, the quantification of CA in the tissue. The CA concentration is difficult to measure accurately due to uncertainties in the imaging, properties of the CA, and physiology of the patient. Paper I, the possibility of using two aspects of the MRI data, phase and magnitude, for improved CA quantification, is explored. We found that the combination of phase and magnitude information improved the CA quantification in regions with high CA concentration, and was more advantageous for high field strength scanners.DW-MRI measures the diffusion of water in and between cells, which reflects the cell density and structure of the tissue. The structure of a tumor can give insights into the prognosis of the disease. Tumors are heterogeneous, both genetically and in the distribution of cells, and tumors with high intratumoral heterogeneity have poorer prognosis. This heterogeneity can be measured using texture analysis. In 1973, Haralick et al. presented a texture analysis method using a gray level co-occurrence matrix, GLCM, to gauge the spatial distribution of gray levels in the image. This method of assessing texture in images has been successfully applied in many areas of research, from satellite images to medical applications. Texture analysis in treatment outcome assessment is studied in Paper II, where we showed that texture can distinguish between groups of patients with different survival times, in images acquired prior to treatment start.However, this type of texture analysis is not inherently quantitative in the way it is calculated today. This was studied in Paper III, where we investigated how texture features were affected by five parameters related to image acquisition and pre-processing. We found that the texture feature values were dependent on the choice of these imaging and preprocessing parameters. In Paper IV, a novel method for calculating Haralick texture features was presented, which makes the texture features asymptotically invariant to the size of the GLCM. This method allows for comparison of textures between images that have been analyzed in different ways.In conclusion, the work in this thesis has been aimed at improving quantitative analysis of tumors using MRI and texture analysis.
  •  
8.
  • Brynolfsson, Patrik, et al. (författare)
  • Gray-level invariant Haralick texture features
  • 2018
  • Ingår i: Radiotherapy and Oncology. - : Elsevier. - 0167-8140 .- 1879-0887. ; 127, s. S279-S280
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
9.
  • Brynolfsson, Patrik, et al. (författare)
  • Haralick texture features from apparent diffusion coefficient (ADC) MRI images depend on imaging and pre-processing parameters
  • 2017
  • Ingår i: Scientific Reports. - : Nature Publishing Group. - 2045-2322. ; 7
  • Tidskriftsartikel (refereegranskat)abstract
    • In recent years, texture analysis of medical images has become increasingly popular in studies investigating diagnosis, classification and treatment response assessment of cancerous disease. Despite numerous applications in oncology and medical imaging in general, there is no consensus regarding texture analysis workflow, or reporting of parameter settings crucial for replication of results. The aim of this study was to assess how sensitive Haralick texture features of apparent diffusion coefficient (ADC) MR images are to changes in five parameters related to image acquisition and pre-processing: noise, resolution, how the ADC map is constructed, the choice of quantization method, and the number of gray levels in the quantized image. We found that noise, resolution, choice of quantization method and the number of gray levels in the quantized images had a significant influence on most texture features, and that the effect size varied between different features. Different methods for constructing the ADC maps did not have an impact on any texture feature. Based on our results, we recommend using images with similar resolutions and noise levels, using one quantization method, and the same number of gray levels in all quantized images, to make meaningful comparisons of texture feature results between different subjects.
  •  
10.
  • Brynolfsson, Patrik, et al. (författare)
  • Technical note : adapting a GE SIGNA PET/MR scanner for radiotherapy
  • 2018
  • Ingår i: Medical physics (Lancaster). - : Wiley-Blackwell Publishing Inc.. - 0094-2405. ; 45:8, s. 3546-3550
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Simultaneous collection of PET and MR data for radiotherapy purposes are useful for, for example, target definition and dose escalations. However, a prerequisite for using PET/MR in the radiotherapy workflow is the ability to image the patient in treatment position. The aim of this work was to adapt a GE SIGNA PET/MR scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (SNR) of the MR images, and the accuracy of the PET attenuation correction. Method: A flat tabletop and a coil holder were developed to image patients in the treatment position, avoid patient contour deformation, and facilitate attenuation correction of flex coils. Attenuation corrections for the developed hardware and an anterior array flex coil were also measured and implemented to the PET/MR system to minimize PET quantitation errors. The reduction of SNR in the MR images due to the added distance between the coils and the patient was evaluated using a large homogenous saline-doped water phantom, and the activity quantitation errors in PET imaging were evaluated with and without the developed attenuation corrections. Result: We showed that the activity quantitation errors in PET imaging were within ±5% when correcting for attenuation of the flat tabletop, coil holder, and flex coil. The SNR of the MRI images were reduced to 74% using the tabletop, and 66% using the tabletop and coil holders. Conclusion: We present a tabletop and coil holder for an anterior array coil to be used with a GE SIGNA PET/MR scanner, for scanning patients in the radiotherapy work flow. Implementing attenuation correction of the added hardware from the radiotherapy setup leads to acceptable PET image quantitation. The drop in SNR in MR images may require adjustment of the imaging protocols.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 52
Typ av publikation
tidskriftsartikel (41)
forskningsöversikt (3)
annan publikation (2)
konferensbidrag (2)
doktorsavhandling (2)
licentiatavhandling (2)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (36)
övrigt vetenskapligt/konstnärligt (16)
Författare/redaktör
Nyholm, Tufve (50)
Jonsson, Joakim, 198 ... (10)
Zackrisson, Björn (9)
Garpebring, Anders (7)
Brynolfsson, Patrik (6)
Lindh, Jack (6)
visa fler...
Gunnlaugsson, Adalst ... (6)
Lindh, Viveca (6)
Löfstedt, Tommy (6)
Bylund, Mikael (5)
Asklund, Thomas (5)
Ångström-Brännström, ... (5)
Axelsson, Jan, 1966- (4)
Olsson, Lars E (4)
Engvall, Gunn, 1955- (4)
Blomqvist, Lennart (4)
Johansson, Adam (4)
Kuess, P. (4)
Adjeiwaah, Mary, 198 ... (3)
Lundman, Josef A. (3)
Söderström, Karin (3)
Thellenberg Karlsson ... (3)
Nilsson, Kristina (3)
Fahlström, Markus (3)
Thellenberg-Karlsson ... (3)
Georg, Dietmar (3)
Strandberg, Sara (2)
Trygg, Johan (2)
Karlsson, Magnus (2)
Nilsson, David (2)
Olsson, Caroline, 19 ... (2)
Edvardsson, David (2)
Daniel, M. (2)
Wallin, Jonas (2)
Larsson, Elna-Marie (2)
Jonsson, Joakim H. (2)
Widmark, Anders (2)
Larsson, Anne (2)
Engvall, Gunn (2)
Blomquist, Erik (2)
Nordström, Fredrik (2)
Baltzer, P (2)
Bolin, David (2)
Helbich, Thomas H. (2)
Valdman, A (2)
Siversson, Carl (2)
Lundman, Josef (2)
Andrzejewski, P. (2)
Helbich, T. (2)
Polanec, S. (2)
visa färre...
Lärosäte
Umeå universitet (50)
Uppsala universitet (21)
Lunds universitet (7)
Karolinska Institutet (6)
Göteborgs universitet (3)
Örebro universitet (1)
visa fler...
Linköpings universitet (1)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (52)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (48)
Naturvetenskap (6)
Teknik (6)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy