SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(O’Connor L.) srt2:(2000-2004)"

Sökning: WFRF:(O’Connor L.) > (2000-2004)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adler, SS, et al. (författare)
  • PHENIX on-line systems
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 560-592
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  •  
3.
  • Adcox, K, et al. (författare)
  • PHENIX central arm tracking detectors
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 489-507
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX tracking system consists of Drift Chambers (DC), Pad Chambers (PC) and the Time Expansion Chamber (TEC). PC1/DC and PC2/TEC/PC3 form the inner and outer tracking units, respectively. These units link the track segments that transverse the RICH and extend to the EMCal. The DC measures charged particle trajectories in the r-phi direction to determine P-T of the particles and the invariant mass of particle pairs. The PCs perform 3D spatial point measurements for pattern recognition and longitudinal momentum reconstruction and provide spatial resolution of a few mm in both r-phi and z. The TEC tracks particles passing through the region between the RICH and the EMCal. The design and operational parameters of the detectors are presented and running experience during the first year of data taking with PHENIX is discussed. The observed spatial and momentum resolution is given which imposes a limitation on the identification and characterization of charged particles in various momentum ranges. (C) 2002 Published by Elsevier Science B.V.
  •  
4.
  •  
5.
  • Glassman, A. H., et al. (författare)
  • Sertraline treatment of major depression in patients with acute MI or unstable angina
  • 2002
  • Ingår i: JAMA. - 0098-7484. ; 288:6, s. 701-9
  • Tidskriftsartikel (refereegranskat)abstract
    • CONTEXT: Major depressive disorder (MDD) occurs in 15% to 23% of patients with acute coronary syndromes and constitutes an independent risk factor for morbidity and mortality. However, no published evidence exists that antidepressant drugs are safe or efficacious in patients with unstable ischemic heart disease. OBJECTIVE: To evaluate the safety and efficacy of sertraline treatment of MDD in patients hospitalized for acute myocardial infarction (MI) or unstable angina and free of other life-threatening medical conditions. DESIGN AND SETTING: Randomized, double-blind, placebo-controlled trial conducted in 40 outpatient cardiology centers and psychiatry clinics in the United States, Europe, Canada, and Australia. Enrollment began in April 1997 and follow-up ended in April 2001. PATIENTS: A total of 369 patients with MDD (64% male; mean age, 57.1 years; mean 17-item Hamilton Depression [HAM-D] score, 19.6; MI, 74%; unstable angina, 26%). INTERVENTION: After a 2-week single-blind placebo run-in, patients were randomly assigned to receive sertraline in flexible dosages of 50 to 200 mg/d (n = 186) or placebo (n = 183) for 24 weeks. MAIN OUTCOME MEASURES: The primary (safety) outcome measure was change from baseline in left ventricular ejection fraction (LVEF); secondary measures included surrogate cardiac measures and cardiovascular adverse events, as well as scores on the HAM-D scale and Clinical Global Impression Improvement scale (CGI-I) in the total randomized sample, in a group with any prior history of MDD, and in a more severe MDD subgroup defined a priori by a HAM-D score of at least 18 and history of 2 or more prior episodes of MDD. RESULTS: Sertraline had no significant effect on mean (SD) LVEF (sertraline: baseline, 54% [10%]; week 16, 54% [11%]; placebo: baseline, 52% [13%]; week 16, 53% [13%]), treatment-emergent increase in ventricular premature complex (VPC) runs (sertraline: 13.1%; placebo: 12.9%), QTc interval greater than 450 milliseconds at end point (sertraline: 12%; placebo: 13%), or other cardiac measures. All comparisons were statistically nonsignificant (P> or = .05). The incidence of severe cardiovascular adverse events was 14.5% with sertraline and 22.4% with placebo. In the total randomized sample, the CGI-I (P =.049), but not the HAM-D (P =.14), favored sertraline. The CGI-I responder rates for sertraline were significantly higher than for placebo in the total sample (67% vs 53%; P =.01), in the group with at least 1 prior episode of depression (72% vs 51%; P =.003), and in the more severe MDD group (78% vs 45%; P =.001). In the latter 2 groups, both CGI-I and HAM-D measures were significantly better in those assigned to sertraline. CONCLUSION: Our results suggest that sertraline is a safe and effective treatment for recurrent depression in patients with recent MI or unstable angina and without other life-threatening medical conditions.
  •  
6.
  •  
7.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy