SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ohlin Acke) srt2:(2000-2004)"

Sökning: WFRF:(Ohlin Acke) > (2000-2004)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Isern, A E, et al. (författare)
  • Grisel syndrome after velopharyngoplasty
  • 2004
  • Ingår i: Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery. - : Informa UK Limited. - 1651-2073 .- 0284-4311. ; 38:1, s. 53-57
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe two patients with Grisel syndrome (atlantoaxial dislocation) after velopharyngoplasty. One required open fixation, while the other was treated with closed reduction and skull traction. Both patients recovered well after long-term follow-up. Early detection and appropiate treatment improve the prognosis.
  •  
3.
  • Karlsson, Magnus, et al. (författare)
  • A modeling capacity of vertebral fractures exists during growth - an up to 47-year follow-up
  • 2003
  • Ingår i: Spine. - 0362-2436. ; 28:18, s. 2087-2092
  • Tidskriftsartikel (refereegranskat)abstract
    • Study Design. The study is an observational cohort study. Objectives. To determine the incidence and the long-term outcome of thoracic or lumbar vertebral fractures in children. Summary of Background Data. The incidence of vertebral fractures in children is described as rare and the outcome as favorable. However, no studies evaluate the clinical and radiographic long-term outcome and if a fractured vertebra could be rebuilt during growth. Method. The incidence of vertebral fractures in children was evaluated through the radiographic archives. Twelve boys and 12 girls, aged 7-16 when sustaining the fracture, 21 one-column compression fractures and 3 burst fractures Denis type B, all without neurologic deficits, attended the follow-up. Primary treatment consisted of immediate mobilization without brace. Clinical and radiographic examination were performed 27-47 years after the injury. Results. The annual incidence of thoracic and lumbar vertebral body fractures in individuals below age 16 was 0.07%. Twenty-one individuals had, at follow-up. no subjective complaints, 3 had occasional back pain (Oswestry Scores, 8, 22, and 26), 23 were classified as Frankel E, and 1 as Frankel D. The radiographic ratio anterior height/posterior height of the fractured vertebral body increased from 0.75 after injury to 0.87 at follow-up (P<0.001). The posttraumatic kyphosis in the fracture region decreased in 8 individuals (33%), all aged 13 or less at fracture. No increased disc degeneration was observed. Conclusion. Thoracolumbar vertebral fractures without neurologic deficits, sustained during growth, have a favorable long-term outcome. A modeling capacity, reducing the fracture deformity exists at least in the youngest patients.
  •  
4.
  •  
5.
  • Sandén, Bengt (författare)
  • Fixation of Spinal Implants : Clinical and Experimental Studies on the Effects of Hydroxyapatite Coating
  • 2001
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Loosening of implants is a frequent complication in orthopaedic surgery. The aim of this thesis was to evaluate hydroxyapatite coating of pedicle screws with mechanical and histological methods and to correlate the results with the radiological findings.Hydroxyapatite (HA) coating of pedicle screws was investigated in experimental studies in sheep. Nine sheep were operated on with destabilising laminectomies at L2-L3 and L4-L5 and stabilised with pedicle screw instrumentations, where HA coated and uncoated screws were used in a randomised fashion. After both 6 and 12 weeks of implantation, the HA coated screws demonstrated a higher bone-to-implant contact and a higher amount of bone in the area close to the screw. The pull-out resistance, stiffness and total energy to failure was higher for the HA coated screws after 12 weeks of implantation.HA coating of pedicle screws was examined in two clinical studies. In the first series, the patients were stabilised with pedicle screw instrumentations, where HA coated screws were used in either the upper or lower instrumented level in a randomised fashion. After 10-22 months of implantation, the extraction torque was markedly higher for the HA coated screws. In the second series, instrumentations with uncoated, partly HA coated or fully HA coated screws were used. After 11-16 months implantation, the extraction torques were recorded. There were significant differences between all three groups, with the lowest extraction torques for the uncoated screws and the highest torques for the fully HA coated screws. The frequency of radiolucent zones surrounding the screws was higher for the uncoated screws than for the HA coated screws.Radiographs from both experimental and clinical studies were examined. Screws demonstrating radiolucent zones were compared to screws without zones with respect to pull-out resistance, extraction torque, bone-to-implant contact and amount of bone surrounding the screws. All these variables demonstrated higher values for the screws without radiolucent zones. The frequency of radiolucent zones surrounding uncoated screws in the clinical study was 53%.Conclusions: Radiolucent zones are good predictors of screw loosening. The frequency of radiolucent zones is higher than previously described. Hydroxyapatite coating improves the purchase of pedicle screws and reduces the frequency of screw loosening.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy