  • Möller, C A, et al. (författare)
  • Distribution of cystatin C (gamma-trace), an inhibitor of lysosomal cysteine proteinases, in the anterior lobe of simian and human pituitary glands
  • 1985
  • Ingår i: Neuroendocrinology. - : S. Karger AG. - 0028-3835 .- 1423-0194. ; 41:5, s. 400-404
  • Tidskriftsartikel (refereegranskat)abstract
    • Cystatin C, a protein inhibitor of lysosomal cysteine proteinases, was demonstrated by immunohistochemical techniques to be present in most luteinizing hormone- (LH-)containing cells in simian and human adenohypophyses. Immunoreactivity of cystatin C was also found in simian adrenocorticotrophic hormone- (ACTH-)containing cells localized to an area corresponding to the pars intermedia but not in the ACTH-containing cells of the anterior pituitary lobe of monkey. No immunoreactivity of cystatin C was detected in the growth hormone- (GH-) and prolactin-containing cells of monkey and man.
  •  
2.
  • Olsson, L E, et al. (författare)
  • Ferrous sulphate gels for determination of absorbed dose distributions using MRI technique : basic studies
  • 1989
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 34:1, s. 43-52
  • Tidskriftsartikel (refereegranskat)abstract
    • Two gels have been found to be suitable to load with ferrous sulphate solution. In these soft tissue equivalent phantoms, the absorbed dose distribution can be measured after irradiation in clinically used MR imaging equipment. The present studies were carried out using a 0.25 T NMR analyser without imaging properties. A ferrous sulphate solution, 0.05 M with respect to sulphuric acid, can be gelled with 4% gelatin to give a dosemeter which has a response which is linearly correlated (r = 0.998) with the absorbed dose in the interval 0-40 Gy. Ferrous sulphate solution can also be gelled with 1% agarose, but this gel has to be purged with oxygen to obtain a linear relationship (r = 0.997) in the same absorbed dose interval. The ferrous sulphate loaded gels have a sensitivity which is a factor of 2.2 or 4.0 times higher for gelatin and agarose, respectively, than the ordinary dosemeter solution. Because the standard deviation of background measurements is higher for the gels than for the dosemeter solution, the minimum detectable absorbed dose is about the same, or 1.0 Gy, for the two gels and the dosemeter solution. The sensitivity of the ferrous sulphate loaded gels shows no dependence on dose rate if the mean dose rate and the absorbed dose per pulse are within the limits normally used by accelerators for radiotherapy.
  •  