SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Oltman M)
 

Sökning: WFRF:(Oltman M) > (2019) > Improvement in diag...

Improvement in diagnostic quality of structural and angiographic MRI of the brain using motion correction with interleaved, volumetric navigators

Andersen, Mads (författare)
Hvidovre Hospital
Björkman-Burtscher, Isabella M. (författare)
Lund University,Lunds universitet,Neuroradiologi,Forskargrupper vid Lunds universitet,Neuroradiology,Lund University Research Groups,Skåne University Hospital
Marsman, Anouk (författare)
Hvidovre Hospital
visa fler...
Petersen, Esben Thade (författare)
Technical University of Denmark,Hvidovre Hospital
Boer, Vincent Oltman (författare)
Hvidovre Hospital
visa färre...
 (creator_code:org_t)
2019-05-17
2019
Engelska.
Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 14:5
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction Subject movements lead to severe artifacts in magnetic resonance (MR) brain imaging. In this study we evaluate the diagnostic image quality in T1-weighted, T2-weighted, and timeof-flight angiographic MR sequences when using a flexible, navigator-based prospective motion correction system (iMOCO). Methods Five healthy volunteers were scanned during different movement scenarios with and without (+/-) iMOCO activated. An experienced neuroradiologist graded images for image quality criteria (grey-white-matter discrimination, basal ganglia, and small structure and vessel delineation), and general image quality on a four-grade scale. Results In scans with deliberate motion, there was a significant improvement in the image quality with iMOCO compared to the scans without iMOCO in both general image impression (T1 p<0.01, T2 p<0.01, TOF p = 0.03) and in anatomical grading (T1 p<0.01, T2 p<0.01, TOF p = 0.01). Subjective image quality was considered non-diagnostic in 91% of the scans with motion -iMOCO, but only in 4% of the scans with motion +iMOCO. iMOCO performed best in the T1-weighted sequence and least well in the angiography sequence. iMOCO was not shown to have any negative effect on diagnostic image quality, as no significant difference in diagnostic quality was seen between scans -iMOCO and +iMOCO with no deliberate movement. Conclusion The evaluation showed that iMOCO enables substantial improvements in image quality in scans affected by subject movement, recovering important diagnostic information in an otherwise unusable scan.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • PLoS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy