SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Oscarsson Bo)
 

Sökning: WFRF:(Oscarsson Bo) > (2015) > Magnetophoretic Tra...

Magnetophoretic Transport Line System for Rapid On-Chip Attomole Protein Detection

Bejhed Stjernberg, Rebecca (författare)
Uppsala universitet,Fasta tillståndets fysik
Tian, Bo (författare)
Uppsala universitet,Fasta tillståndets fysik
Eriksson, Kristofer (författare)
Uppsala universitet,Fasta tillståndets fysik
visa fler...
Brucas, Rimantas (författare)
Uppsala universitet,Fasta tillståndets fysik
Oscarsson, Sven (författare)
Stockholms universitet,Institutionen för organisk kemi,Stockholm Univ, Arrhenius Lab, Dept Organ Chem, SE-10691 Stockholm, Sweden.
Strömberg, Mattias (författare)
Uppsala universitet,Fasta tillståndets fysik
Svedlindh, Peter (författare)
Uppsala universitet,Fasta tillståndets fysik
Gunnarsson, Klas (författare)
Uppsala universitet,Fasta tillståndets fysik
visa färre...
 (creator_code:org_t)
2015-09-04
2015
Engelska.
Ingår i: Langmuir. - : American Chemical Society (ACS). - 0743-7463 .- 1520-5827. ; 31:37, s. 10296-10302
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A lab-on-a-chip traveling wave magnetophoresis approach for sensitive and rapid protein detection is reported. In this method, a chip-based magnetic microarray comprising lines of micrometer-sized thin film magnetic elements was used to control the movement of magnetic beads (MBs). The MBs and the chip were functionalized, forming a sandwich-type assay. The MBs were transported across a detection area, and the presence of target molecules resulted in the immobilization of MBs within this area. Target quantification was accomplished by MB counting in the detection area using an optical microscope. In order to demonstrate the versatility of the microarray, biotinylated antiavidin was selected as the target protein. In this case, avidin-functionalized MBs and an avidin-functionalized detection area were used. With a total assay time of 1 to 1.5 h (depending on the labeling approach used), a limit of detection in the attomole range was achieved. Compared to on-chip surface plasmon resonance biodetection systems, our method has a larger dynamic range and is about a factor of 500 times more sensitive. Furthermore, our MB transportation system can operate in any chip-based biosensor platform, thereby significantly improving traditional biosensors.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering (hsv//eng)
NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Langmuir (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy