1.
  • Dekhuijzen, P. N Richard, et al. (författare)
  • Incidence of oral thrush in patients with COPD prescribed inhaled corticosteroids : Effect of drug, dose, and device
  • 2016
  • Ingår i: Respiratory Medicine. - : Elsevier BV. - 0954-6111. ; 120, s. 54-63
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and aims Little information is available on real-life occurrence of oral thrush in COPD patients treated with ICS. We investigated oral thrush incidence in COPD patients prescribed FDC ICS/LABA therapies and assessed whether it is modulated by the ICS type, dose, and delivery device. Methods We conducted a historical, observational, matched cohort study (one baseline year before and one outcome year after initiation of therapy) using data from the UK Optimum Patient Care Research Database. We assessed oral thrush incidence in patients initiating long-acting bronchodilators or FDC ICS/LABA therapy. We then compared different combination therapies (budesonide/formoterol fumarate dihydrate [BUD/FOR] and fluticasone propionate/salmeterol xinafoate [FP/SAL]) and devices (DPI and pMDI). Results Patients prescribed FDC ICS/LABA had significantly greater odds of experiencing oral thrush than those prescribed long-acting bronchodilators alone (adjusted OR 2.18 [95% CI 1.84–2.59]). Significantly fewer patients prescribed BUD/FOR DPI developed oral thrush compared with FP/SAL DPI (OR 0.77 [0.63–0.94]) when allowing for differences in prescribed doses between the drugs. A significantly smaller proportion of patients developed oral thrush in the FP/SAL pMDI arm than in the FP/SAL DPI arm (OR 0.67 [0.55–0.82]). Additionally, in the FP/SAL cohort (both DPI and pMDI), increased risk of oral thrush was significantly associated with high ICS daily dose (OR 1.97 [1.22–3.17] vs low daily dose). Conclusions ICS use increases oral thrush incidence in COPD and this effect is dose-dependent for FP/SAL therapies. Of the therapies assessed, FP/SAL pMDI and BUD/FOR DPI may be more protective against oral thrush.
  •  
2.
  • Westerik, Janine A. M., et al. (författare)
  • Characteristics of patients making serious inhaler errors with a dry powder inhaler and association with asthma-related events in a primary care setting
  • 2016
  • Ingår i: Journal of Asthma. - : Informa UK Limited. - 0277-0903 .- 1532-4303. ; 53:3, s. 321-329
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Correct inhaler technique is central to effective delivery of asthma therapy. The study aim was to identify factors associated with serious inhaler technique errors and their prevalence among primary care patients with asthma using the Diskus dry powder inhaler (DPI).Methods: This was a historical, multinational, cross-sectional study (2011-2013) using the iHARP database, an international initiative that includes patient- and healthcare provider-reported questionnaires from eight countries. Patients with asthma were observed for serious inhaler errors by trained healthcare providers as predefined by the iHARP steering committee. Multivariable logistic regression, stepwise reduced, was used to identify clinical characteristics and asthma-related outcomes associated with 1 serious errors.Results: Of 3681 patients with asthma, 623 (17%) were using a Diskus (mean [SD] age, 51 [14]; 61% women). A total of 341 (55%) patients made 1 serious errors. The most common errors were the failure to exhale before inhalation, insufficient breath-hold at the end of inhalation, and inhalation that was not forceful from the start. Factors significantly associated with 1 serious errors included asthma-related hospitalization the previous year (odds ratio [OR] 2.07; 95% confidence interval [CI], 1.26-3.40); obesity (OR 1.75; 1.17-2.63); poor asthma control the previous 4 weeks (OR 1.57; 1.04-2.36); female sex (OR 1.51; 1.08-2.10); and no inhaler technique review during the previous year (OR 1.45; 1.04-2.02).Conclusions: Patients with evidence of poor asthma control should be targeted for a review of their inhaler technique even when using a device thought to have a low error rate.
  •  