SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Pavlopoulos P) srt2:(2000-2004)"

Sökning: WFRF:(Pavlopoulos P) > (2000-2004)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Periale, L., et al. (författare)
  • Successful operation of hole-type gaseous detectors at cryogenic temperatures
  • 2004
  • Ingår i: 2004 IEEE Nuclear Science Symposium Conference Record. - 0780387007 ; , s. 1147-1151
  • Konferensbidrag (refereegranskat)abstract
    • We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 103 in the entire temperature interval between 300 until 77 K. The same capillary plate combined with Csi photocathodes could operate perfectly well at gains (depending on gas mixtures) of 100-1000. Obtained results may open new fields of applications for capillary plates as detectors of UV light and charge particles at cryogenic temperatures: noble liquid TPCs, WIMP detectors or LXe scintillating calorimeters and cryogenic PETs.
  •  
3.
  • Iacobaeus, C., et al. (författare)
  • An X-ray scanner based on an "edge on" illuminated capillary plate combined with a gas amplification structure
  • 2004
  • Ingår i: 2004 IEEE Nuclear Science Symposium Conference Record. ; , s. 489-492
  • Konferensbidrag (refereegranskat)abstract
    • We have developed and successfully tested a prototype of a new type of high position resolution X-ray scanner. It contains a thin wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche chamber operating in various gas mixtures at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0-90°. The detection efficiency, depending on the geometry, photon's energy, incident angle and the mode of operation, was between 5-30% in a single step mode and up to 50% in a multi-layered combination. Depending on the capillary's geometry, the position resolution achieved was between 50-250 μm in digital form and was practically independent of the photon's energy or gas mixture. The usual lead glass capillary plates operated without noticeable charging up effects at counting rates of 50 Hz/mm2, and hydrogen treated capillaries up to 10 5 Hz/mm2. Finally, a prototype of the X-ray scanner based on an "edge-on" illumination capillary plate was built and tested. The developed detector open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), crystallography and many other applications.
  •  
4.
  • Periale, L., et al. (författare)
  • The development of gaseous detectors with solid photocathodes for low-temperature applications
  • 2004
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 535:02-jan, s. 517-522
  • Tidskriftsartikel (refereegranskat)abstract
    • There are several applications and studies in fundamental research, which require the detection of VUV light at cryogenic temperatures. For these applications, we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrated that both primary and secondary (due to the avalanche multiplication inside liquids) scintillation light can be recorded by photosensitive gaseous detectors. The results of this work may allow one to significantly improve the operation of some noble liquid TPCs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy