SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Peltola M.) srt2:(2010-2014)"

Search: WFRF:(Peltola M.) > (2010-2014)

  • Result 1-10 of 12
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Gupta, A., et al. (author)
  • A four-kallikrein panel for the prediction of repeat prostate biopsy: data from the European Randomized Study of Prostate Cancer Screening in Rotterdam, Netherlands
  • 2010
  • In: British Journal of Cancer. - : Springer Science and Business Media LLC. - 1532-1827 .- 0007-0920. ; 103:5, s. 708-714
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Most men with elevated levels of prostate-specific antigen (PSA) do not have prostate cancer, leading to a large number of unnecessary biopsies. A statistical model based on a panel of four kallikreins has been shown to predict the outcome of a first prostate biopsy. In this study, we apply the model to an independent data set of men with previous negative biopsy but persistently elevated PSA. METHODS: The study cohort consisted of 925 men with a previous negative prostate biopsy and elevated PSA (>= 3 ngml(-1)), with 110 prostate cancers detected (12%). A previously published statistical model was applied, with recalibration to reflect the lower positive biopsy rates on rebiopsy. RESULTS: The full-kallikrein panel had higher discriminative accuracy than PSA and DRE alone, with area under the curve (AUC) improving from 0.58 (95% confidence interval (CI): 0.52, 0.64) to 0.68 (95% CI: 0.62, 0.74), P<0.001, and high-grade cancer (Gleason >= 7) at biopsy with AUC improving from 0.76 (95% CI: 0.64, 0.89) to 0.87 (95% CI: 0.81, 0.94), P 0.003). Application of the panel to 1000 men with persistently elevated PSA after initial negative biopsy, at a 15% risk threshold would reduce the number of biopsies by 712; would miss (or delay) the diagnosis of 53 cancers, of which only 3 would be Gleason 7 and the rest Gleason 6 or less. CONCLUSIONS: Our data constitute an external validation of a previously published model. The four-kallikrein panel predicts the result of repeat prostate biopsy in men with elevated PSA while dramatically decreasing unnecessary biopsies. British Journal of Cancer (2010) 103, 708-714. doi:10.1038/sj.bjc.6605815 www.bjcancer.com Published online 27 July 2010 (C) 2010 Cancer Research UK
  •  
2.
  •  
3.
  • Kaplan, Alexander, et al. (author)
  • Stress raising in laser clad components depending on geometry and defects
  • 2013
  • In: 14th NOLAMP Conference. - Luleå : Luleå tekniska universitet. - 9789174396881 - 9789174396898 ; , s. 281-292
  • Conference paper (other academic/artistic)abstract
    • The fatigue life of laser clad components is basically determined by stress raisers, which arehere studied by Finite Element Analysis. Cylindrical and square section bars are compared foraxial, bending and torsional load conditions, which induces the macro-stress field withcorresponding stress peaks. Defects from laser cladding such as pores, cracks or the surfaceroughness superimpose additional stress raising action on this stress field. The geometricalposition and orientation of the defects has strong impact on the induced maximum stresslevel. For surface pores it is demonstrated by the fractography that their occurrence within acritical azimuthal range can initiate fatigue cracking. The different conditions of samplegeometry, load situations, materials and defects are compared and discussed. In particular,advanced illustration methods are applied for improved and generalized documentation andexplanation of the trends, both qualitatively and quantitatively. Guidelines are presented, inparticular emphasizing critical defects and situations, such as surface pores that are difficult todetect because of inclusions, or pores just underneath the surface that generate particularlyhigh stress.
  •  
4.
  •  
5.
  • Forssman, Linda, et al. (author)
  • Regulatory variant of the TPH2 gene and early life stress are associated with heightened attention to social signals of fear in infants
  • 2014
  • In: Journal of Child Psychology and Psychiatry. - : Wiley. - 0021-9630 .- 1469-7610. ; 55:7, s. 793-801
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Cross-species evidence suggests that genetic and experiential factors act early in development to establish individual emotional traits, but little is known about the mechanisms that emerge during this period to mediate long-term outcomes. Here, we tested the hypothesis that known genetic and environmental risk conditions may heighten infants' natural tendency to attend to threat-alerting stimuli, resulting in a cognitive bias that may contribute to emotional vulnerability.METHODS: Data from two samples of 5-7-month-old infants (N = 139) were used to examine whether established candidate variations in the serotonin-system genes, i.e., TPH2 SNP rs4570625 (-703 G/T) and HTR1A SNP rs6295 (-1019 G/C), and early rearing condition (maternal stress and depressive symptoms) are associated with alterations in infants' attention to facial expressions. Infants were tested with a paradigm that assesses the ability to disengage attention from a centrally presented stimulus (a nonface control stimulus or a neutral, happy, or fearful facial expression) toward the location of a new stimulus in the visual periphery (a geometric shape).RESULTS: TPH2 -703 T-carrier genotype (i.e., TT homozygotes and heterozygotes), presence of maternal stress and depressive symptoms, and a combination of the T-carrier genotype and maternal depressive symptoms were associated with a relatively greater difficulty disengaging attention from fearful facial expressions. No associations were found with infants' temperamental traits.CONCLUSIONS: Alterations in infants' natural attentional bias toward fearful facial expressions may emerge prior to the manifestation of emotional and social behaviors and provide a sensitive marker of early emotional development.
  •  
6.
  • Haiman, Christopher A, et al. (author)
  • Levels of Beta-Microseminoprotein in Blood and Risk of Prostate Cancer in Multiple Populations.
  • 2012
  • In: Journal of the National Cancer Institute. - : Oxford University Press (OUP). - 1460-2105 .- 0027-8874.
  • Journal article (peer-reviewed)abstract
    • BackgroundA common genetic variant (rs10993994) in the 5' region of the gene encoding β-microseminoprotein (MSP) is associated with circulating levels of MSP and prostate cancer risk. Whether MSP levels are predictive of prostate cancer risk has not been evaluated.MethodsWe investigated the prospective relationship between circulating plasma levels of MSP and prostate cancer risk in a nested case-control study of 1503 case subjects and 1503 control subjects among black, Latino, Japanese, Native Hawaiian, and white men from the Multiethnic Cohort study. We also examined the ability of MSP to serve as a biomarker for discriminating prostate cancer case subjects from control subjects. All statistical tests are two-sided.ResultsIn all racial and ethnic groups, men with lower MSP levels were at greater risk of developing prostate cancer (odds ratio = 1.02 per one unit decrease in MSP, P < .001 in the prostate-specific antigen [PSA]-adjusted analysis). Compared with men in the highest decile of MSP, the multivariable PSA-adjusted odds ratio was 3.64 (95% confidence interval = 2.41 to 5.49) for men in the lowest decile. The positive association with lower MSP levels was observed consistently across racial and ethnic populations, by disease stage and Gleason score, for men with both high and low levels of PSA and across all genotype classes of rs10993994. However, we did not detect strong evidence of MSP levels in improving prostate cancer prediction beyond that of PSA.ConclusionsRegardless of race and ethnicity or rs10993994 genotype, men with low blood levels of MSP have increased risk of prostate cancer.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Peltola, O., et al. (author)
  • Evaluating the performance of commonly used gas analysers for methane eddy covariance flux measurements: the InGOS inter-comparison field experiment
  • 2014
  • In: Biogeosciences. - : Copernicus GmbH. - 1726-4189. ; 11:12, s. 3163-3186
  • Journal article (peer-reviewed)abstract
    • The performance of eight fast-response methane (CH4) gas analysers suitable for eddy covariance flux measurements were tested at a grassland site near the Cabauw tall tower (Netherlands) during June 2012. The instruments were positioned close to each other in order to minimise the effect of varying turbulent conditions. The moderate CH4 fluxes observed at the location, of the order of 25 nmol m(-2) s(-1), provided a suitable signal for testing the instruments' performance. Generally, all analysers tested were able to quantify the concentration fluctuations at the frequency range relevant for turbulent exchange and were able to deliver high-quality data. The tested cavity ringdown spectrometer (CRDS) instruments from Picarro, models G2311-f and G1301-f, were superior to other CH4 analysers with respect to instrumental noise. As an open-path instrument susceptible to the effects of rain, the LI-COR LI-7700 achieved lower data coverage and also required larger density corrections; however, the system is especially useful for remote sites that are restricted in power availability. In this study the open-path LI-7700 results were compromised due to a data acquisition problem in our data-logging setup. Some of the older closed-path analysers tested do not measure H2O concentrations alongside CH4 (i.e. FMA1 and DLT-100 by Los Gatos Research) and this complicates data processing since the required corrections for dilution and spectroscopic interactions have to be based on external information. To overcome this issue, we used H2O mole fractions measured by other gas analysers, adjusted them with different methods and then applied them to correct the CH4 fluxes. Following this procedure we estimated a bias of the order of 0.1 g (CH4) m(-2) (8% of the measured mean flux) in the processed and corrected CH4 fluxes on a monthly scale due to missing H2O concentration measurements. Finally, cumulative CH4 fluxes over 14 days from three closed-path gas analysers, G2311-f (Picarro Inc.), FGGA (Los Gatos Research) and FMA2 (Los Gatos Research), which were measuring H2O concentrations in addition to CH4, agreed within 3% (355-367 mg (CH4) m(-2)) and were not clearly different from each other, whereas the other instruments derived total fluxes which showed small but distinct differences (+/- 10 %, 330-399 mg (CH4) m(-2)).
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view