1.
  • Sacchetto, Daniela, et al. (författare)
  • Mammographic density : Comparison of visual assessment with fully automatic calculation on a multivendor dataset
  • 2016
  • Ingår i: European Radiology. - : Springer. - 0938-7994 .- 1432-1084. ; 26:1, s. 175-183
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare breast density (BD) assessment provided by an automated BD evaluator (ABDE) with that provided by a panel of experienced breast radiologists, on a multivendor dataset. Twenty-one radiologists assessed 613 screening/diagnostic digital mammograms from nine centers and six different vendors, using the BI-RADS a, b, c, and d density classification. The same mammograms were also evaluated by an ABDE providing the ratio between fibroglandular and total breast area on a continuous scale and, automatically, the BI-RADS score. A panel majority report (PMR) was used as reference standard. Agreement (kappa) and accuracy (proportion of cases correctly classified) were calculated for binary (BI-RADS a-b versus c-d) and 4-class classification. While the agreement of individual radiologists with the PMR ranged from kappa = 0.483 to kappa = 0.885, the ABDE correctly classified 563/613 mammograms (92 %). A substantial agreement for binary classification was found for individual reader pairs (kappa = 0.620, standard deviation [SD] = 0.140), individual versus PMR (kappa = 0.736, SD = 0.117), and individual versus ABDE (kappa = 0.674, SD = 0.095). Agreement between ABDE and PMR was almost perfect (kappa = 0.831). The ABDE showed an almost perfect agreement with a 21-radiologist panel in binary BD classification on a multivendor dataset, earning a chance as a reproducible alternative to visual evaluation. aEuro cent Individual BD assessment differs from PMR with kappa as low as 0.483. aEuro cent An ABDE correctly classified 92 % of mammograms with almost perfect agreement (kappa = 0.831). aEuro cent An ABDE can be a valid alternative to subjective BD assessment.
  •  
2.
  • Fransson, Claes, et al. (författare)
  • THE DESTRUCTION OF THE CIRCUMSTELLAR RING OF SN 1987A
  • 2015
  • Ingår i: Astrophysical Journal Letters. - 2041-8205 .- 2041-8213. ; 806:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We present imaging and spectroscopic observations with Hubble Space Telescope and Very Large Telescope of the ring of SN 1987A from 1994 to 2014. After an almost exponential increase of the shocked emission from the hotspots up to day similar to 8000 (similar to 2009), both this and the unshocked emission are now fading. From the radial positions of the hotspots we see an acceleration of these up to 500-1000 km s(-1), consistent with the highest spectroscopic shock velocities from the radiative shocks. In the most recent observations (2013 and 2014), we find several new hotspots outside the inner ring, excited by either X-rays from the shocks or by direct shock interaction. All of these observations indicate that the interaction with the supernova ejecta is now gradually dissolving the hotspots. We predict, based on the observed decay, that the inner ring will be destroyed by similar to 2025.
  •  