SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Platzer S) srt2:(2010-2014)"

Sökning: WFRF:(Platzer S) > (2010-2014)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Acharya, B. S., et al. (författare)
  • Introducing the CTA concept
  • 2013
  • Ingår i: Astroparticle physics. - : Elsevier BV. - 0927-6505 .- 1873-2852. ; 43, s. 3-18
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The Cherenkov Telescope Array (CTA) is a new observatory for very high-energy (VHE) gamma rays. CTA has ambitions science goals, for which it is necessary to achieve full-sky coverage, to improve the sensitivity by about an order of magnitude, to span about four decades of energy, from a few tens of GeV to above 100 TeV with enhanced angular and energy resolutions over existing VHE gamma-ray observatories. An international collaboration has formed with more than 1000 members from 27 countries in Europe, Asia, Africa and North and South America. In 2010 the CTA Consortium completed a Design Study and started a three-year Preparatory Phase which leads to production readiness of CTA in 2014. In this paper we introduce the science goals and the concept of CTA, and provide an overview of the project. (C) 2013 Elsevier B.V. All rights reserved.
  •  
2.
  • Actis, M., et al. (författare)
  • Design concepts for the Cherenkov Telescope Array CTA : an advanced facility for ground-based high-energy gamma-ray astronomy
  • 2011
  • Ingår i: Experimental astronomy. - : Springer. - 0922-6435 .- 1572-9508. ; 32:3, s. 193-316
  • Tidskriftsartikel (refereegranskat)abstract
    • Ground-based gamma-ray astronomy has had a major breakthrough with the impressive results obtained using systems of imaging atmospheric Cherenkov telescopes. Ground-based gamma-ray astronomy has a huge potential in astrophysics, particle physics and cosmology. CTA is an international initiative to build the next generation instrument, with a factor of 5-10 improvement in sensitivity in the 100 GeV-10 TeV range and the extension to energies well below 100 GeV and above 100 TeV. CTA will consist of two arrays (one in the north, one in the south) for full sky coverage and will be operated as open observatory. The design of CTA is based on currently available technology. This document reports on the status and presents the major design concepts of CTA.
  •  
3.
  • Biazar, C., et al. (författare)
  • Cutaneous lupus erythematosus : First multicenter database analysis of 1002 patients from the European Society of Cutaneous Lupus Erythematosus (EUSCLE)
  • 2013
  • Ingår i: Autoimmunity Reviews. - : Elsevier BV. - 1568-9972 .- 1873-0183. ; 12:3, s. 444-454
  • Forskningsöversikt (refereegranskat)abstract
    • In this prospective, cross-sectional, multicenter study, we assessed clinical and laboratory characteristics from patients with cutaneous lupus erythematosus (CLE) using the Core Set Questionnaire of the European Society of Cutaneous Lupus Erythematosus (EUSCLE). 1002 (768 females, 234 males) patients with different subtypes of CLE, such as acute CLE (ACLE, 304 patients), subacute CLE (SCLE, 236 patients), chronic CLE (CCLE, 397 patients), and intermittent CLE (ICLE, 65 patients), from 13 European countries were collected and statistically analyzed by an SPSS database. The main outcome measures included gender, age at onset of disease, LE-specific and LE-nonspecific skin lesions, photosensitivity, laboratory features, and the criteria of the American College of Rheumatology (ACR) for the classification of systemic lupus erythematosus. The mean age at onset of disease was 43.0±15.7 years and differed significantly between the CLE subtypes. In 347 (34.6%) of the 1002 patients, two or more CLE subtypes were diagnosed during the course of the disease and 453 (45.2%) presented with LE-nonspecific manifestations. Drug-induced CLE and SjögrenD́s Syndrome had the highest prevalence in SCLE patients (13.1% and 14.0%, respectively). Photosensitivity was significantly more frequent in patients with ACLE, SCLE, and ICLE compared with those with CCLE. The detection of antinuclear antibodies such as anti-Ro/SSA and anti-La/SSB antibodies revealed further significant differences between the CLE subtypes. In summary, the EUSCLE Core Set Questionnaire and its database facilitate the analysis of clinical and laboratory features in a high number of patients with CLE and will contribute to standardized assessment and monitoring of the disease in Europe.
  •  
4.
  • Naghavi, N., et al. (författare)
  • Buffer layers and transparent conducting oxides for chalcopyrite Cu(In,Ga)(S,Se)(2) based thin film photovoltaics : Present status and current developments
  • 2010
  • Ingår i: Progress in Photovoltaics. - : Wiley. - 1062-7995 .- 1099-159X. ; 18:6, s. 411-433
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the present contribution is to give a review on the recent work concerning Cd-free buffer and window layers in chalcopyrite solar cells using various deposition techniques as well as on their adaptation to chalcopyrite-type absorbers such as Cu(In,Ga)Se-2, CuInS2, or Cu(In,Ga)(S,Se)(2). The corresponding solar-cell performances, the expected technological problems, and current attempts for their commercialization will be discussed. The most important deposition techniques developed in this paper are chemical bath deposition, atomic layer deposition, ILGAR deposition, evaporation, and spray deposition. These deposition methods were employed essentially for buffers based on the following three materials: In2S3, ZnS, Zn1-xMgxO.
  •  
5.
  • Mongstad, Trygve, et al. (författare)
  • MgyNi1-y(H-x) thin films deposited by magnetron co-sputtering
  • 2012
  • Ingår i: Journal of Alloys and Compounds. - : Elsevier BV. - 0925-8388 .- 1873-4669. ; 527, s. 76-83
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work we have synthesized thin films of MgyNi1-y(H-x) metal and metal hydride with y between 0 and 1. The films are deposited by magnetron co-sputtering of metallic targets of Mg and Ni. Metallic MgyNi1-y films were deposited with pure Ar plasma while MgyNi1-yHx hydride films were deposited reactively with 30% H-2 in the Ar plasma. The depositions were done with a fixed substrate carrier, producing films with a spatial gradient in the Mg and Ni composition. The combinatorial method of co-sputtering gives an insight into the phase diagram of MgyNi1-y and MgyNi1-yHx, and allows us to investigate structural, optical and electrical properties of the resulting alloys. Our results show that reactive sputtering gives direct deposition of metal hydride films, with high purity in the case of Mg similar to 2NiH similar to 4. We have observed limited oxidation after several months of exposure to ambient conditions. MgyNi1-y and MgyNi1-yHx films might be applied for optical control in smart windows, optical sensors and as a semiconducting material for photovoltaic solar cells.
  •  
6.
  • Mongstad, Trygve, et al. (författare)
  • Surface oxide on thin films of yttrium hydride studied by neutron reflectometry
  • 2012
  • Ingår i: Applied Physics Letters. - : AIP Publishing. - 0003-6951 .- 1077-3118. ; 100:19, s. 191604-
  • Tidskriftsartikel (refereegranskat)abstract
    • The applicability of standard methods for compositional analysis is limited for H-containing films. Neutron reflectometry is a powerful, non-destructive method that is especially suitable for these systems due to the large negative scattering length of H. In this work, we demonstrate how neutron reflectometry can be used to investigate thin films of yttrium hydride. Neutron reflectometry gives a strong contrast between the film and the surface oxide layer, enabling us to estimate the oxide thickness and oxygen penetration depths. A surface oxide layer of 5-10nm thickness was found for unprotected yttrium hydride films.
  •  
7.
  •  
8.
  • Mongstad, T, et al. (författare)
  • Transparent yttrium hydride thin films prepared by reactive sputtering
  • 2011
  • Ingår i: Journal of Alloys and Compounds. - : Elsevier BV. - 0925-8388 .- 1873-4669. ; 509, s. S812-S816
  • Tidskriftsartikel (refereegranskat)abstract
    • Metal hydrides have earlier been suggested for utilization in solar cells. With this as a motivation we have prepared thin films of yttrium hydride by reactive magnetron sputter deposition. The resulting films are metallic for low partial pressure of hydrogen during the deposition, and black or yellow-transparent for higher partial pressure of hydrogen. Both metallic and semiconducting transparent YH(x) films have been prepared directly in situ without the need of capping layers and post-deposition hydrogenation. Optically the films are similar to what is found for YH(x) films prepared by other techniques, but the crystal structure of the transparent films differ from the well-known YH(3-eta) phase, as they have an fcc lattice instead of hcp.
  •  
9.
  •  
10.
  • Platzer-Bjorkman, Charlotte, et al. (författare)
  • Diffusion of Fe and Na in co-evaporated Cu(In, Ga) Se-2 devices on steel substrates
  • 2013
  • Ingår i: Thin Solid Films. - : Elsevier BV. - 0040-6090 .- 1879-2731. ; 535, s. 188-192
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work we study impurity diffusion into Cu(In, Ga) Se-2 from stainless steel substrates with and without Cr diffusion barriers using secondary ion mass spectrometry. For these substrate configurations we compare cases with and without adding NaF as a sodium precursor. A clear increase in impurity diffusion from the substrate is observed for samples with NaF. Devices made using our micro pilot line show the expected correlation between Fe content, Na content and efficiency, but the highest device efficiency obtained for steel substrates is still slightly below that of the glass substrate reference. We discuss reasons for the observed device performance.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy