SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Plogmaker Stefan)
 

Sökning: WFRF:(Plogmaker Stefan) > (2017) > A setup for element...

A setup for element specific magnetization dynamics using the transverse magneto-optic Kerr effect in the energy range of 30-72 eV

Jana, Somnath (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
Terschlüsen, Joachim A. (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
Stefanuik, Robert (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
visa fler...
Plogmaker, Stefan (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik,MAX VI Lab, Lund, Sweden.
Troisi, Sara (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
Malik, Rameez S. (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
Svanqvist, Mathias (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik,Swedish Def Res Agcy, FOI, SE-14725 Tumba, Sweden.
Knut, Ronny (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
Söderström, Johan, 1978- (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
Karis, Olof (författare)
Uppsala universitet,Molekyl- och kondenserade materiens fysik
visa färre...
 (creator_code:org_t)
AMER INST PHYSICS, 2017
2017
Engelska.
Ingår i: Review of Scientific Instruments. - : AMER INST PHYSICS. - 0034-6748 .- 1089-7623. ; 88:3
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this paper, we present a spectrometer that is designed for element-specific and time-resolved transverse magneto-optic Kerr effect experiments at the high-harmonic generation pump-probe facility High Energy Laser Induced Overtone Source (HELIOS) laboratory. HELIOS delivers photons with energies between 30 eV and 72 eV with an overall time resolution of less than 40 fs. The spectrometer is based on a Rowland-circle geometry and allows for simultaneous measurements of all magnetic transition-metal elements. The setup also features easy sample transfer and alignment, and it combines high photon throughput, optimized data acquisition, and a fast switching of the magnetic field at the sample. The spectrometer performance is demonstrated by measuring the ultrafast demagnetization of permalloy. Our data are, for all practical purposes, identical to what have been reported in the earlier high-order harmonic generation work of a similar sample by Mathias et al. [Proc. Natl. Acad. Sci. U.S.A. 109, 4792-4797 (2012)], however, obtained within 15% of the acquisition time compared to their study. Furthermore, our data show a shift of the demagnetization curve of Ni relative to Fe, which has previously been interpreted as a delay of the Ni demagnetization to that of Fe [S. Mathias et al., Proc. Natl. Acad. Sci. U. S. A. 109, 4792-4797 (2012)].

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)
NATURVETENSKAP  -- Fysik -- Den kondenserade materiens fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Condensed Matter Physics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy