SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Qvarlander Sara Teknisk doktor 1982 ) srt2:(2020)"

Sökning: WFRF:(Qvarlander Sara Teknisk doktor 1982 ) > (2020)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jóhannesson, Gauti, 1979-, et al. (författare)
  • Intraocular Pressure Decrease Does Not Affect Blood Flow Rate of Ophthalmic Artery in Ocular Hypertension
  • 2020
  • Ingår i: Investigative Ophthalmology and Visual Science. - : Association for Research in Vision and Ophthalmology. - 0146-0404 .- 1552-5783. ; 61:12
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To investigate if decrease of IOP affects the volumetric blood flow rate in the ophthalmic artery (OA) in patients with previously untreated ocular hypertension.METHODS: Subjects with untreated ocular hypertension (n = 30; mean age 67 +/- 8 years; 14 females) underwent ophthalmologic examination and a 3-Tesla magnetic resonance imaging investigation. The magnetic resonance imaging included three-dimensional high-resolution phase-contrast magnetic resonance imaging to measure the OA blood flow rate. The subjects received latanoprost once daily in the eye with higher pressure, the untreated eye served as control. The same measurements were repeated approximately 1 week later.RESULTS: The mean OA blood flow rate before and after treatment was 12.4 +/- 4.4 and 12.4 +/- 4.6 mL/min in the treated eye (mean +/- SD; P = 0.92) and 13.5 +/- 5.2 and 13.4 +/- 4.1 mL/min in the control eye (P = 0.92). There was no significant difference between the treated and control eye regarding blood flow rate before (P = 0.13) or after treatment (P = 0.18), or change in blood flow rate after treatment (0.1 +/- 3.1 vs.-0.1 +/- 4.0 mL/min, P = 0.84). Latanoprost decreased the IOP by 7.2 +/- 3.1 mm Hg in the treated eye (P < 0.01).CONCLUSIONS: The results indicate that a significant lowering of IOP does not affect the blood flow rate of the OA in ocular hypertension subjects. The ability to maintain blood supply to the eye independent of the IOP could be a protective mechanism in preserving vision in subjects with ocular hypertension.
  •  
2.
  • Luciano, Mark G., et al. (författare)
  • Epidural Oscillating Cardiac-Gated Intracranial Implant Modulates Cerebral Blood Flow
  • 2020
  • Ingår i: Neurosurgery. - : Oxford University Press. - 0148-396X .- 1524-4040. ; 87:6, s. 1299-1310
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: We have previously reported a method and device capable of manipulating ICP pulsatility while minimally effecting mean ICP.Objective: To test the hypothesis that different modulations of the intracranial pressure (ICP) pulse waveform will have a differential effect on cerebral blood flow (CBF).Methods: Using an epidural balloon catheter attached to a cardiac-gated oscillating pump, 13 canine subjects underwent ICP waveform manipulation comparing different sequences of oscillation in successive animals. The epidural balloon was implanted unilaterally superior to the Sylvian sulcus. Subjects underwent ICP pulse augmentation, reduction and inversion protocols, directly comparing time segments of system activation and deactivation. ICP and CBF were measured bilaterally along with systemic pressure and heart rate. CBF was measured using both thermal diffusion, and laser doppler probes.Results: The activation of the cardiac-gate balloon implant resulted in an ipsilateral/contralateral ICP pulse amplitude increase with augmentation (217%/202% respectively, P < .0005) and inversion (139%/120%, P < .0005). The observed changes associated with the ICP mean values were smaller, increasing with augmentation (23%/31%, P < .0001) while decreasing with inversion (7%/11%, P = .006/.0003) and reduction (4%/5%, P < .0005). CBF increase was observed for both inversion and reduction protocols (28%/7.4%, P < .0001/P = .006 and 2.4%/1.3%, P < .0001/P = .003), but not the augmentation protocol. The change in CBF was correlated with ICP pulse amplitude and systolic peak changes and not with change in mean ICP or systemic variables (heart rate, arterial blood pressure).Conclusion: Cardiac-gated manipulation of ICP pulsatility allows the study of intracranial pulsatile dynamics and provides a potential means of altering CBF.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy