SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rück Andreas) srt2:(2020-2024)"

Sökning: WFRF:(Rück Andreas) > (2020-2024)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Isomura, Kayoko, et al. (författare)
  • Risk of specific cardiovascular diseases in obsessive-compulsive disorder
  • 2020
  • Ingår i: Journal of Psychiatric Research. - : Elsevier. - 0022-3956 .- 1879-1379. ; 135, s. 189-196
  • Tidskriftsartikel (refereegranskat)abstract
    • Individuals with obsessive-compulsive disorder (OCD) may have an increased risk of cardiovascular disease (CVD), but evidence for specific types of CVD is limited. This population-based, sibling-controlled cohort study investigated the risk of specific CVD in individuals with OCD. Linking data from various Swedish population-based registers, we explored the risk of a range of CVD in a cohort of individuals diagnosed with OCD between 1973 and 2013 (n = 33,561), compared to matched (1:10) unaffected individuals (n = 335,610). Hazard ratios (HR) with 95% confidence intervals (CI) were calculated using conditional Cox proportional hazards regression models, adjusting for history of somatic diseases. To control for familial confounders, we analyzed 23,263 clusters of full siblings discordant for OCD. Individuals with psychiatric comorbidities were systematically excluded to assess the impact of these comorbidities. Over an average follow-up time of 27 years, OCD was associated with an increased risk of a broad range of CVD (adjusted HR [aHR] for any CVD = 1.25 [95% confidence interval [CI], 1.22-1.29]). These associations were strongest for the subtypes venous thrombo-embolism (aHR = 1.48 [95% CI, 1.38-1.58]) and heart failure (aHR = 1.37 [95% CI, 1.28-1.46]). When comparing OCD-exposed individuals with their non-exposed full siblings, results were largely similar. Exclusion of several groups of psychiatric comorbidities resulted in comparable results, albeit attenuated. Individuals with OCD have a moderately increased risk of CVD-related morbidity, independent from history of somatic diseases, familial confounders, and psychiatric comorbidities. The time may be ripe for the development and evaluation of lifestyle interventions to help reduce the risk of cardiovascular morbidity in OCD.
  •  
2.
  • Bjursten, Henrik, et al. (författare)
  • Characteristics and Outcomes of Patients Receiving a Second Rescue Valve During Transcatheter Aortic Valve Implantation
  • 2024
  • Ingår i: Structural Heart. - : Elsevier. - 2474-8706 .- 2474-8714. ; 8:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Transcatheter aortic valve implantation (TAVI) has become a safe procedure. However, complications occur, including uncommon complications such as valve malposition, which requires the implantation of an additional rescue valve (rescue-AV). The aim was to study the occurrence and outcomes of rescue-AV in a nationwide registry. Methods: The Swedish national TAVI registry was used as the primary data source, where all 6706 TAVI procedures from 2016 to 2021 were retrieved. Nontransfemoral access and planned valve-in-valve were excluded. In total, 79 patients were identified as having had a rescue-AV, and additional detailed data were collected for these patients. This dataset was analyzed for any characteristics that could predispose patients to a rescue-AV. The outcome of patients receiving rescue-AV also was studied. Results: Of the 5948 patients in the study, 1.3% had a rescue-AV. There were few differences between patients receiving 1 valve and rescue-AV patients. For patients receiving a rescue-AV, the 30-day mortality was 15.2% compared to 1.6% in the control group. A poor outcome after rescue-AV was often associated with a second complication; for example, stroke, need for emergency surgery, or heart failure. Among the patients with rescue-AV who survived at least 30 days, landmark analyses showed similar survival rates compared to the control group. Conclusions: Among TAVI patients in a nationwide register, rescue-AV occurred in 1.3% of patients. The 30-day mortality in patients receiving rescue-AV was high, but long-term outcome among 30-day survivors was similar to the control group.
  •  
3.
  • Bjursten, Henrik, et al. (författare)
  • Characteristics and Outcomes of Patients Receiving a Second Rescue Valve During Transcatheter Aortic Valve Implantation
  • 2024
  • Ingår i: Structural Heart. - : Elsevier. - 2474-8706 .- 2474-8714. ; 8:2
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundTranscatheter aortic valve implantation (TAVI) has become a safe procedure. However, complications occur, including uncommon complications such as valve malposition, which requires the implantation of an additional rescue valve (rescue-AV). The aim was to study the occurrence and outcomes of rescue-AV in a nationwide registry.MethodsThe Swedish national TAVI registry was used as the primary data source, where all 6706 TAVI procedures from 2016 to 2021 were retrieved. Nontransfemoral access and planned valve-in-valve were excluded. In total, 79 patients were identified as having had a rescue-AV, and additional detailed data were collected for these patients. This dataset was analyzed for any characteristics that could predispose patients to a rescue-AV. The outcome of patients receiving rescue-AV also was studied.ResultsOf the 5948 patients in the study, 1.3% had a rescue-AV. There were few differences between patients receiving 1 valve and rescue-AV patients. For patients receiving a rescue-AV, the 30-day mortality was 15.2% compared to 1.6% in the control group. A poor outcome after rescue-AV was often associated with a second complication; for example, stroke, need for emergency surgery, or heart failure. Among the patients with rescue-AV who survived at least 30 days, landmark analyses showed similar survival rates compared to the control group.ConclusionsAmong TAVI patients in a nationwide register, rescue-AV occurred in 1.3% of patients. The 30-day mortality in patients receiving rescue-AV was high, but long-term outcome among 30-day survivors was similar to the control group.
  •  
4.
  • Bohm, Felix, et al. (författare)
  • FFR-Guided Complete or Culprit-Only PCI in Patients with Myocardial Infarction
  • 2024
  • Ingår i: New England Journal of Medicine. - : MASSACHUSETTS MEDICAL SOC. - 0028-4793 .- 1533-4406.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The benefit of fractional flow reserve (FFR)-guided complete revascularization in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease remains unclear.Methods In this multinational, registry-based, randomized trial, we assigned patients with STEMI or very-high-risk non-STEMI (NSTEMI) and multivessel disease who were undergoing primary percutaneous coronary intervention (PCI) of the culprit lesion to receive either FFR-guided complete revascularization of nonculprit lesions or no further revascularization. The primary outcome was a composite of death from any cause, myocardial infarction, or unplanned revascularization. The two key secondary outcomes were a composite of death from any cause or myocardial infarction and unplanned revascularization.Results A total of 1542 patients underwent randomization, with 764 assigned to receive FFR-guided complete revascularization and 778 assigned to receive culprit-lesion-only PCI. At a median follow-up of 4.8 years (interquartile range, 4.3 to 5.2), a primary-outcome event had occurred in 145 patients (19.0%) in the complete-revascularization group and in 159 patients (20.4%) in the culprit-lesion-only group (hazard ratio, 0.93; 95% confidence interval [CI], 0.74 to 1.17; P=0.53). With respect to the secondary outcomes, no apparent between-group differences were observed in the composite of death from any cause or myocardial infarction (hazard ratio, 1.12; 95% CI, 0.87 to 1.44) or unplanned revascularization (hazard ratio, 0.76; 95% CI, 0.56 to 1.04). There were no apparent between-group differences in safety outcomes.Conclusions Among patients with STEMI or very-high-risk NSTEMI and multivessel coronary artery disease, FFR-guided complete revascularization was not shown to result in a lower risk of a composite of death from any cause, myocardial infarction, or unplanned revascularization than culprit-lesion-only PCI at 4.8 years. (Funded by the Swedish Research Council and others; FULL REVASC ClinicalTrials.gov number, NCT02862119.) In a registry-based trial, FFR-guided PCI of nonculprit lesions did not result in a lower risk of a composite of death from any cause, myocardial infarction, or unplanned revascularization than culprit-lesion-only PCI.
  •  
5.
  • Böhm, Felix, et al. (författare)
  • FFR-Guided Complete or Culprit-Only PCI in Patients with Myocardial Infarction
  • 2024
  • Ingår i: New England Journal of Medicine. - : Massachusetts Medical Society. - 0028-4793 .- 1533-4406. ; 390:16, s. 1481-1492
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The benefit of fractional flow reserve (FFR)-guided complete revascularization in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease remains unclear. METHODS: In this multinational, registry-based, randomized trial, we assigned patients with STEMI or very-high-risk non-STEMI (NSTEMI) and multivessel disease who were undergoing primary percutaneous coronary intervention (PCI) of the culprit lesion to receive either FFR-guided complete revascularization of nonculprit lesions or no further revascularization. The primary outcome was a composite of death from any cause, myocardial infarction, or unplanned revascularization. The two key secondary outcomes were a composite of death from any cause or myocardial infarction and unplanned revascularization. RESULTS: A total of 1542 patients underwent randomization, with 764 assigned to receive FFR-guided complete revascularization and 778 assigned to receive culprit-lesion-only PCI. At a median follow-up of 4.8 years (interquartile range, 4.3 to 5.2), a primary-outcome event had occurred in 145 patients (19.0%) in the complete-revascularization group and in 159 patients (20.4%) in the culprit-lesion-only group (hazard ratio, 0.93; 95% confidence interval [CI], 0.74 to 1.17; P = 0.53). With respect to the secondary outcomes, no apparent between-group differences were observed in the composite of death from any cause or myocardial infarction (hazard ratio, 1.12; 95% CI, 0.87 to 1.44) or unplanned revascularization (hazard ratio, 0.76; 95% CI, 0.56 to 1.04). There were no apparent between-group differences in safety outcomes. CONCLUSIONS: Among patients with STEMI or very-high-risk NSTEMI and multivessel coronary artery disease, FFR-guided complete revascularization was not shown to result in a lower risk of a composite of death from any cause, myocardial infarction, or unplanned revascularization than culprit-lesion-only PCI at 4.8 years. (Funded by the Swedish Research Council and others; FULL REVASC ClinicalTrials.gov number, NCT02862119.).
  •  
6.
  • Böhm, Felix, et al. (författare)
  • The Full Revasc (Ffr-gUidance for compLete non-cuLprit REVASCularization) Registry-based randomized clinical trial
  • 2021
  • Ingår i: American Heart Journal. - : Elsevier. - 0002-8703 .- 1097-6744. ; 241, s. 92-100
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Complete revascularization in ST elevation myocardial infarction (STEMI) patients with multivessel disease has resulted in reduction in composite clinical endpoints in medium sized trials. Only one trial showed an effect on hard clinical endpoints, but the revascularization procedure was guided by angiographic evaluation of stenosis severity. Consequently, it is not clear how Fractional Flow Reserve (FFR)-guided percutaneous coronary intervention (PCI) affects hard clinical endpoints in STEMI. Methods and Results The Ffr-gUidance for compLete non-cuLprit REVASCularization (FULL REVASC) - is a pragmatic, multicenter, international, registry-based randomized clinical trial designed to evaluate whether a strategy of FFR-guided complete revascularization of non-culprit lesions, reduces the combined primary endpoint of total mortality, non-fatal MI and unplanned revascularization. 1,545 patients were randomized to receive FFR-guided PCI during the index hospitalization or initial conservative management of non-culprit lesions. We found that in angiographically severe non-culprit lesions of 90-99% severity, 1 in 5 of these lesions were re-classified as non-flow limiting by FFR. Considering lesions of intermediate severity (70%-89%), half were re-classified as non-flow limiting by FFR. The study is event driven for an estimated follow-up of at least 2.75 years to detect a 9.9%/year >7.425%/year difference (HR = 0.74 at 80% power (alpha = .05)) for the combined primary endpoint. Conclusion This large randomized clinical trial is designed and powered to evaluate the effect of complete revascularization with FFR-guided PCI during index hospitalization on total mortality, non-fatal MI and unplanned revascularization following primary PCI in STEMI patients with multivessel disease. Enrollment completed in September 2019 and follow-up is ongoing.
  •  
7.
  • Elkoumy, Ahmed, et al. (författare)
  • ACURATE neo2 Transcatheter aortic valve implantation without balloon aortic valvuloplasty : direct ACURATE neo2
  • 2024
  • Ingår i: International Journal of Cardiology. - 0167-5273 .- 1874-1754. ; 400
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. Aim: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. Methodology: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. Results: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. Conclusion: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.
  •  
8.
  • Elkoumy, Ahmed, et al. (författare)
  • Core Lab Adjudication of the ACURATE neo2 Hemodynamic Performance Using Computed-Tomography-Corrected Left Ventricular Outflow Tract Area
  • 2022
  • Ingår i: Journal of Clinical Medicine. - : MDPI AG. - 2077-0383. ; 11:20, s. 1-12
  • Tidskriftsartikel (refereegranskat)abstract
    • (1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Doppler-derived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 ± 62.04 mm2 vs. 405.22 ± 81.32 mm2) (95% Credible interval (CrI) of differences: −55.15, −36.09), which resulted in smaller EOA (2.25 ± 0.59 vs. 2.58 ± 0.63 cm2) (Beta = −0.642 (95%CrI of differences: −0.85, −0.43), and lower SV (73.88 ± 21.41 vs. 84.47 ± 22.66 mL), (Beta = −7.29 (95% CrI: −14.45, −0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies.
  •  
9.
  • Kim, Won Keun, et al. (författare)
  • Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice : one-yearresults of the ACURATE neo2 PMCF Study
  • 2024
  • Ingår i: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213. ; 20:1, s. 85-94
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).
  •  
10.
  • Nilsson, Konrad, et al. (författare)
  • Causes, pattern, predictors, and prognostic implications of new hospitalizations after transcatheter aortic valve implantation : a long-term nationwide observational study
  • 2022
  • Ingår i: European Heart Journal - Quality of Care and Clinical Outcomes. - : Oxford University Press (OUP). - 2058-5225 .- 2058-1742. ; 8:2, s. 150-160
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The aim of this study was to investigate the pattern, causes, and predictors of all new hospitalizations in patients who underwent transcatheter aortic valve implantation (TAVI).METHODS AND RESULTS: The nationwide Swedish TAVI registry was merged with other mandatory healthcare registries, which enabled the analysis of all TAVI procedures, new hospital admissions, and death between the years 2008 and 2017. A total of 2821 patients underwent TAVI with a mean of 2.5 hospitalizations during a mean follow-up of 2.2 years. Hospitalizations were associated with worse prognosis. Heart failure (HF) was the most common cause of hospitalization with 19% having at least one hospitalization due to HF causing, 16% of all-cause admissions, and 50% of cardiovascular admissions. Male gender, age >90 years, high Charlson Comorbidity Index, atrial fibrillation, present neurologic disease, severe renal impairment, peripheral vascular disease, New York Heart Association class IV, mild or moderate mean aortic valve gradients, and pulmonary hypertension were associated with an increased risk for all-cause hospitalizations or death. For cardiovascular hospitalization or death, the pattern was similar, with the addition of impaired systolic left ventricular function as a predictor.CONCLUSION: Multiple hospitalizations after TAVI are common and are often caused by HF. Reducing the rate of HF hospitalizations is important to mitigate the burden on the healthcare system due to new hospitalizations after TAVI.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12
Typ av publikation
tidskriftsartikel (12)
Typ av innehåll
refereegranskat (12)
Författare/redaktör
Rück, Andreas (11)
Götberg, Matthias (5)
Bjursten, Henrik (5)
Laine, Mika (5)
James, Stefan, 1964- (3)
Koul, Sasha (3)
visa fler...
Erglis, Andrejs (3)
Abdel-Wahab, Mohamed (3)
Hengstenberg, Christ ... (3)
Schultz, Carl (3)
Stankovic, Goran (3)
Menon, Madhav (3)
Rudolph, Tanja K. (3)
Saleh, Nawzad (3)
Johansson, Jan (2)
Andersson, Jonas (2)
Abdelshafy, Mahmoud (2)
Sondergaard, Lars (2)
James, Stefan (2)
Held, Claes (2)
Böhm, Felix (2)
Östlund, Ollie (2)
Kellerth, Thomas (2)
Rück, Christian (2)
Petursson, Petur, 19 ... (2)
Odenstedt, Jacob, 19 ... (2)
De Backer, Ole (2)
Hagström, Henrik (2)
Backes, Jenny (2)
Nielsen, Niels Erik, ... (2)
Settergren, Magnus (2)
Yndigen, Troels (2)
Renlund, Henrik (2)
Engstrom, Thomas (2)
Srdanovic, Ilija (2)
Zwackman, Sammy (2)
Hamid, Mehmet (2)
Kajander, Olli A. (2)
Linder, Rikard (2)
Thiele, Holger (2)
Mogensen, Brynjölfur (2)
Wolf, Alexander (2)
Elkoumy, Ahmed (2)
Wambach, Jan Martin (2)
Arsang-Jang, Shahram (2)
Elzomor, Hesham (2)
Wykrzykowska, Joanna ... (2)
Mohamed, Sameh K. (2)
Pellegrini, Costanza (2)
Toggweiler, Stefan (2)
visa färre...
Lärosäte
Karolinska Institutet (11)
Lunds universitet (7)
Uppsala universitet (6)
Linköpings universitet (5)
Umeå universitet (4)
Göteborgs universitet (3)
visa fler...
Kungliga Tekniska Högskolan (1)
Stockholms universitet (1)
Örebro universitet (1)
visa färre...
Språk
Engelska (12)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (12)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy