SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Raijmakers Pieter G) srt2:(2014)"

Sökning: WFRF:(Raijmakers Pieter G) > (2014)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Danad, Ibrahim, et al. (författare)
  • Effect of cardiac hybrid O-15-water PET/CT imaging on downstream referral for invasive coronary angiography and revascularization rate
  • 2014
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 15:2, s. 170-179
  • Tidskriftsartikel (refereegranskat)abstract
    • This study evaluates the impact of hybrid imaging on referral for invasive coronary angiography (ICA) and revascularization rates. A total of 375 patients underwent hybrid O-15-water positron emission tomography (PET)/computed tomography (CT)-based coronary angiography (CTCA) imaging for the evaluation of coronary artery disease (CAD). Downstream treatment strategy within a 60-day period after hybrid PET/CTCA imaging for ICA referral and revascularization was assessed. CTCA examinations were classified as showing no (obstructive) CAD, equivocal (borderline test result), or obstructive CAD, while the PET perfusion images were classified into normal or abnormal. On the basis of CTCA imaging, 182 (49) patients displayed no (obstructive) CAD. Only 10 (5) patients who showed no (obstructive) CAD on CTCA were referred for ICA, which were all negative. An equivocal CT study was observed in 80 (21) patients, among whom 56 (70) showed normal myocardial perfusion imaging (MPI), resulting in referral rates for ICA of 18 for normal MPI and 71 for abnormal MPI, respectively. No revascularizations were performed in the presence of normal MPI, while 59 of those with abnormal MPI were revascularized. CTCA indentified obstructive CAD in 113 (30) patients accompanied in 59 (52) patients with abnormal MPI. Referral rate for ICA was 57 for normal MPI and 88 for those with abnormal MPI, resulting in revascularization rates of 26 and 72, respectively. Hybrid O-15-water PET/CTCA imaging impacts clinical decision-making with regard to referral for ICA and revascularization procedures. Particularly, in the presence of an equivocal or abnormal CTCA, MPI could guide in the decision to refer for ICA and revascularization.
  •  
2.
  • Danad, Ibrahim, et al. (författare)
  • Impact of anatomical and functional severity of coronary atherosclerotic plaques on the transmural perfusion gradient : a [O-15]H2O PET study
  • 2014
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 35:31, s. 2094-U149
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Myocardial ischaemia occurs principally in the subendocardial layer, whereas conventional myocardial perfusion imaging provides no information on the transmural myocardial blood flow (MBF) distribution. Subendocardial perfusion measurements and quantification of the transmural perfusion gradient (TPG) could be more sensitive and specific for the detection of coronary artery disease (CAD). The current study aimed to determine the impact of lesion severity as assessed by the fractional flow reserve (FFR) on subendocardial perfusion and the TPG using [O-15]H2O positron emission tomography (PET) imaging in patients evaluated for CAD. Methods and results Sixty-six patients with anginal chest pain were prospectively enrolled and underwent [O-15] H2O myocardial perfusion PET imaging. Subsequently, invasive coronary angiography was performed and FFR obtained in all coronary arteries irrespective of the PET imaging results. Thirty (45%) patients were diagnosed with significant CAD(i.e. FFR <= 0.80), whereas on a per vessel analysis (n = 198), 53 (27%) displayed a positive FFR. Transmural hyperaemic MBF decreased significantly from 3.09 +/- 1.16 to 1.67 +/- 0.57 mL min(-1) g(-1) (P < 0.001) in non-ischaemic and ischaemic myocardium, respectively. The TPG decreased during hyperaemia when compared with baseline (1.20 +/- 0.14 vs. 0.94 +/- 0.17, P < 0.001), and was lower in arteries with a positive FFR (0.97 +/- 0.16 vs. 0.88 +/- 0.18, P < 0.01). ATPG threshold of 0.94 yielded an accuracy to detect CAD of 59%, which was inferior to transmural MBF with an optimal cutoff of 2.20 mL min(-1) g(-1) and an accuracy of 85% (P < 0.001). Diagnostic accuracy of subendocardial perfusion measurements was comparable with transmural MBF (83 vs. 85%, respectively, P = NS). Conclusion Cardiac [O-15]H2O PET imaging is able to distinguish subendocardial from subepicardial perfusion in the myocardium of normal dimensions. Hyperaemic TPG is significantly lower in ischaemic myocardium. This technique can potentially be employed to study subendocardial perfusion impairment in more detail. However, the diagnostic accuracy of subendocardial hyperaemic perfusion and TPG appears to be limited compared with quantitative transmural MBF, warranting further study.
  •  
3.
  • Danad, Ibrahim, et al. (författare)
  • Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [O-15]H2O PET Imaging
  • 2014
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097 .- 1558-3597. ; 64:14, s. 1464-1475
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Recent studies have demonstrated improved diagnostic accuracy for detecting coronary artery disease (CAD) when myocardial blood flow (MBF) is quantified in absolute terms, but there are no uniformly accepted cutoff values for hemodynamically significant CAD. OBJECTIVES The goal of this study was to determine cutoff values for absolute MBF and to evaluate the diagnostic accuracy of quantitative [O-15]H2O positron emission tomography (PET). METHODS A total of 330 patients underwent both quantitative [O-15]H2O PET imaging and invasive coronary angiography in conjunction with fractional flow reserve measurements. A stenosis >90% and/or fractional flow reserve <= 0.80 was considered obstructive; a stenosis <30% and/or fractional flow reserve >0.80 was nonobstructive. RESULTS Hemodynamically significant CAD was diagnosed in 116 (41%) of 281 patients who fulfilled study criteria for CAD. Resting perfusion was 1.00 +/- 0.25 and 0.92 +/- 0.23 ml/min/g in regions supplied by nonstenotic and significantly stenosed vessels, respectively (p < 0.001). During stress, perfusion increased to 3.26 +/- 1.04 ml/min/g and 1.73 +/- 0.67 ml/min/g, respectively (p < 0.001). The optimal cutoff values were 2.3 and 2.5 for hyperemic MBF and myocardial flow reserve, respectively. For MBF, these cutoff values showed a sensitivity, specificity, and accuracy for detecting significant CAD of 89%, 84%, and 86%, respectively, at a per-patient level and 87%, 85%, and 85% at a per-vessel level. The corresponding myocardial flow reserve values were 86%, 72%, and 78% (per patient) and 80%, 82%, and 81% (per vessel). Age and sex significantly affected diagnostic accuracy of quantitative PET. CONCLUSIONS Quantitative MBF measurements with the use of [O-15]H2O PET provided high diagnostic performance, but both sex and age should be taken into account.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy