SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Recchia E.) srt2:(2009)"

Sökning: WFRF:(Recchia E.) > (2009)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Valiente-Dobon, J. J., et al. (författare)
  • Lifetime Measurements of the Neutron-Rich N=30 Isotones Ca-50 and Sc-51: Orbital Dependence of Effective Charges in the fp Shell
  • 2009
  • Ingår i: Physical Review Letters. - 1079-7114. ; 102:24
  • Tidskriftsartikel (refereegranskat)abstract
    • The lifetimes of the first excited states of the N=30 isotones Ca-50 and Sc-51 have been determined using the Recoil Distance Doppler Shift method in combination with the CLARA-PRISMA spectrometers. This is the first time such a method is applied to measure lifetimes of neutron-rich nuclei populated via a multinucleon transfer reaction. This extends the lifetime knowledge beyond the f(7/2) shell closure and allows us to derive the effective proton and neutron charges in the fp shell near the doubly magic nucleus Ca-48, using large-scale, shell-model calculations. These results indicate an orbital dependence of the core polarization along the fp shell.
  •  
2.
  •  
3.
  • Recchia, F, et al. (författare)
  • Position resolution of the prototype AGATA triple-cluster detector from an in-beam experiment
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 604:3, s. 555-562
  • Tidskriftsartikel (refereegranskat)abstract
    • AGATA belongs to a new generation of gamma-ray detector arrays for nuclear spectroscopy at present in its final stage of development. The detectors of these new arrays will be based on 36-fold electronically segmented coaxial germanium diodes operated in position sensitive mode. An in-beam test of the AGATA prototype triple cluster detector was carried out with the purpose of demonstrating the feasibility of such detectors and in order to measure the most sensitive parameters for their overall performance. An inverse kinematics reaction was performed, using a Ti-48 beam at an energy of 100MeV, impinging on a deuterated titanium tat-get. The results from the analysis of the experimental data, compared with the predictions of Monte Carlo Simulations, give an estimation of the position sensitivity of these detectors of about 5 mm FWHM, consistent with the specifications required. (C) 2009 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy