SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rodes Cabau J)
 

Sökning: WFRF:(Rodes Cabau J) > (2015) > The impact of calci...

The impact of calcium volume and distribution in aortic root injury related to balloon-expandable transcatheter aortic valve replacement

Hansson, Nicolaj C. (författare)
Aarhus University Hospital, Denmark
Norgaard, Bjarne L. (författare)
Aarhus University Hospital, Denmark
Barbanti, Marco (författare)
St Pauls Hospital, Canada; University of Catania, Italy
visa fler...
Nielsen, Niels Erik (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Region Östergötland, Kardiologiska kliniken US
Yang, Tae-Hyun (författare)
St Pauls Hospital, Canada; Inje University, South Korea
Tamburino, Corrado (författare)
University of Catania, Italy
Dvir, Danny (författare)
St Pauls Hospital, Canada
Jilaihawi, Hasan (författare)
Cedars Sinai Heart Institute, CA USA
Blanke, Philip (författare)
University Hospital Freiburg, Germany
Makkar, Raj R. (författare)
Cedars Sinai Heart Institute, CA USA
Latib, Azeem (författare)
EMO GVM Centre Cuore Columbus, Italy; Ist Science San Raffaele, Italy
Colombo, Antonio (författare)
EMO GVM Centre Cuore Columbus, Italy; Ist Science San Raffaele, Italy
Tarantini, Giuseppe (författare)
University of Padua, Italy
Raju, Rekha (författare)
St Pauls Hospital, Canada
Wood, David (författare)
St Pauls Hospital, Canada
Andersen, Henning R. (författare)
Aarhus University Hospital, Denmark
Ribeiro, Henrique B. (författare)
University of Laval, Canada
Kapadia, Samir (författare)
Cleveland Clin, OH 44106 USA
Min, James (författare)
Cedars Sinai Heart Institute, CA USA
Feuchtner, Gudrun (författare)
Medical University of Innsbruck, Austria
Gurvitch, Ronen (författare)
Royal Melbourne Hospital, Australia
Alqoofi, Faisal (författare)
University of Calgary, Canada
Pelletier, Marc (författare)
New Brunswick Heart Centre, Canada
Paolo Ussia, Gian (författare)
University of Roma Tor Vergata, Italy
Napodano, Massimo (författare)
EMO GVM Centre Cuore Columbus, Italy; Ist Science San Raffaele, Italy
de Brito, Fabio Sandoli Jr. (författare)
Hospital Israelita Albert Einstein, Brazil
Kodali, Susheel (författare)
Columbia University, NY USA
Pache, Gregor (författare)
University Hospital Freiburg, Germany
Canovas, Sergio J. (författare)
Arrixaca University Hospital, Spain
Berger, Adam (författare)
St Pauls Hospital, Canada
Murphy, Darra (författare)
St Pauls Hospital, Canada
Svensson, Lars G. (författare)
Cleveland Clin, OH 44106 USA
Rodes-Cabau, Josep (författare)
University of Laval, Canada
Leon, Martin B. (författare)
Columbia University, NY USA
Webb, John G. (författare)
St Pauls Hospital, Canada
Leipsic, Jonathon (författare)
St Pauls Hospital, Canada
visa färre...
 (creator_code:org_t)
ELSEVIER SCIENCE INC, 2015
2015
Engelska.
Ingår i: JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY. - : ELSEVIER SCIENCE INC. - 1934-5925. ; 9:5, s. 382-392
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: A detailed assessment of calcium within the aortic root may provide important additional information regarding the risk of aortic root injury during transcatheter heart valve replacement (TAVR). Objective: We sought to delineate the effect of calcium volume and distribution on aortic root injury during TAVR. Methods: Thirty-three patients experiencing aortic root injury during TAVR with a balloon-expandable valve were compared with a control group of 153 consecutive TAVR patients without aortic root injury (as assessed by post-TAVR multidetector CT). Using commercial software to analyze contrast-enhanced pre-TAVR CT scans, caltium volume was determined in 3 regions: (1) the overall left ventricular outflow tract (LVOT), extending 10 mm down from the aortic annulus plane; (2) the upper LVOT, extending 2 mm down from the annulus plane; and (3) the aortic valve region. Results: Calcium volumes in the upper LVOT (median, 29 vs 0 mm(3); P less than .0001) and overall LVOT (median, 74 vs 3 mm(3); P = .0001) were higher in patients who experienced aortic root injury compared with the control group. Calcium in the aortic valve region did not differ between groups. Upper LVOT calcium volume was more predictive of aortic root injury than overall LVOT calcium volume (area under receiver operating curve [AUG]; 0.78; 95% confidence interval, 0.69-0.86 vs AUC, 0.71; 95% confidence interval, 0.62-0.82; P = .010). Upper LVOT calcium below the noncoronary cusp was significantly more predictive of aortic root injury compared to calcium underneath the right coronary cusp or the left coronary cusp (AUC, 0.81 vs 0.68 vs 0.64). Prosthesis oversizing greater than20% (likelihood ratio test, P = .028) and redilatation (likelihood ratio test, P = .015) improved prediction of aortic root injury by upper LVOT calcium volume. Conclusion: Calcification of the LVOT, especially in the upper LVOT, located below the noncoronary cusp and extending from the annular region, is predictive of aortic root injury during TAVR with a balloon-expandable valve. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

Aortic root calcification; Aortic root injury; Multidetector computed tomography; Transcatheter aortic valve replacement

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy