SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ruck Andreas) srt2:(2010-2014)"

Sökning: WFRF:(Ruck Andreas) > (2010-2014)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Bergström, Jan, 1976-, et al. (författare)
  • Internet-versus group-administered cognitive behaviour therapy for panic disorder in a psychiatric setting : a randomised trial
  • 2010
  • Ingår i: BMC Psychiatry. - : BioMed Central Ltd. - 1471-244X. ; 10:54
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Internet administered cognitive behaviour therapy (CBT) is a promising new way to deliver psychological treatment, but its effectiveness in regular care settings and in relation to more traditional CBT group treatment has not yet been determined. The primary aim of this study was to compare the effectiveness of Internetand group administered CBT for panic disorder (with or without agoraphobia) in a randomised trial within a regular psychiatric care setting. The second aim of the study was to establish the cost-effectiveness of these interventions. Methods: Patients referred for treatment by their physician, or self-referred, were telephone-screened by a psychiatric nurse. Patients fulfilling screening criteria underwent an in-person structured clinical interview carried out by a psychiatrist. A total of 113 consecutive patients were then randomly assigned to 10 weeks of either guided Internet delivered CBT (n = 53) or group CBT (n = 60). After treatment, and at a 6-month follow-up, patients were again assessed by the psychiatrist, blind to treatment condition. Results: Immediately after randomization 9 patients dropped out, leaving 104 patients who started treatment. Patients in both treatment conditions showed  significant improvement on the main outcome measure, the Panic Disorder Severity Scale (PDSS) after treatment. For the Internet treatment the within-group effect size (pre-post) on the PDSS was Cohen's d = 1.73, and for the group treatment it was d = 1.63. Between group effect sizes were low and treatment effects were maintained at 6-months follow-up. We found no statistically significant differences between the two treatment conditions using a mixed models approach to account for missing data. Group CBT utilised considerably more therapist time than did Internet CBT. Defining effect as proportion of PDSS responders, the cost-effectiveness analysis concerning therapist time showed that Internet treatment had superior cost-effectiveness ratios in relation to group treatment both at post-treatment and follow-up. Conclusions: This study provides support for the effectiveness of Internet CBT in a psychiatric setting for patients with panic disorder, and suggests that it is equally effective as the more widely used group administered CBT in reducing panic-and agoraphobic symptoms, as well as being more cost effective with respect to therapist time.
  •  
3.
  • da Silva, Cristina, et al. (författare)
  • Prosthesis-patient mismatch after transcatheter aortic valve implantation : impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography
  • 2014
  • Ingår i: The International Journal of Cardiovascular Imaging. - : Springer Science and Business Media LLC. - 1569-5794 .- 1875-8312 .- 1573-0743. ; 30:8, s. 1549-1557
  • Tidskriftsartikel (refereegranskat)abstract
    • To investigate the role of 2D-transthoracic echocardiography (2D-TTE) and 3D-transesophageal echocardiography (3D-TEE) in the determination of aortic annulus size prior transcatheter aortic valve implantation (TAVI) and its' impact on the prevalence of patient prosthesis mismatch (PPM). Echocardiography plays an important role in measuring aortic annulus dimension in patients undergoing TAVI. This has great importance since it determines both eligibility for TAVI and selection of prosthesis type and size, and can be potentially important in preventing an inadequate ratio between the prosthetic valvular orifice and the patient's body surface area, concept known as prosthesis-patient mismatch (PPM). A total of 45 patients were studied pre-TAVI: 20 underwent 3D-TEE (men/women 12/8, age 84.8 +/- A 5.6) and 25 2D-TTE (men/women 9/16, age 84.4 +/- A 5.4) in order to measure aortic annulus diameter. The presence of PPM was assessed before hospital discharge and after a mean period of 3 months. Moderate PPM was defined as indexed aortic valve area (AVAi) a parts per thousand currency sign 0.85 cm(2)/m(2) and severe PPM as AVAi < 0.65 cm(2)/m(2). Immediately post-TAVI, moderate PPM was present in 25 and 28 % of patients worked up using 3D-TEE and 2D-TTE respectively p value = n.s) and severe PPM occurred in 10 % of the patients who underwent 3D-TEE and in 20 % in those with 2D-TTE (p value = n.s). The echocardiographic evaluation 3 months post-TAVI showed 25 % moderate PPM in the 3D-TEE group compared with 24 % in the 2D-TTE group (p value = n.s) and no cases of severe PPM in the 3DTEE group comparing to 20 % in the 2D-TTE group (p = 0.032). Our results indicate a higher incidence of severe PPM in patients who performed 2DTTE compared to those performing 3DTEE prior TAVI. This suggests that the 3D technique should replace the 2DTTE analysis when investigating the aortic annulus diameter in patients undergoing TAVI.
  •  
4.
  •  
5.
  •  
6.
  • Ripsweden, Jonaz, et al. (författare)
  • Impact on image quality and radiation exposure in coronary CT angiography: 100 kVp versus 120 kVp
  • 2010
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 51:8, s. 903-909
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The risk of radiation-induced cancer has become a major concern with the increasing use of computed tomography (CT). Purpose: To compare image quality and radiation doses when decreasing X-ray tube peak kilovoltage (kVp) from 120 to 100 kVp in patients undergoing coronary CT angiography (CCTA). Material and Methods: Patients referred for evaluation of suspected coronary artery disease (CAD) underwent 64-channel detector CCTA using a tube voltage of either 120 kVp (n = 46) or 100 kVp (n = 82). The individual volume CT dose index (CTDIvol) and dose length product (DLP) were recorded and effective radiation dose was estimated on the basis of DLP. Subjective image quality was assessed by two radiologists on per-patient based consensus. Vascular density and image noise were quantified in the left main coronary artery (LMCA) and proximal ascending aorta (AA). Mean density in the adjacent perivascular tissue was also quantified. Contrast-to-noise ratio (CNR) was calculated. Corresponding invasive coronary angiography (ICA) was performed, which constituted the gold standard. Results: Mean values in the 100120 kVp cohorts regarding CNR in the LMCA were 12.716.0 (P < 0.0001)) and in the AA 13.217.2 (P < 0.0001), CTDIvol 34.457.4 mGy (a 40% reduction, P < 0.0001), DLP 5781125 mGy X cm (P < 0.0001), and estimated effective dose 9.620.2 mSv (P < 0.0001). There was no statistically significant difference in subjective image quality between the two cohorts. The sensitivity to detect significant coronary stenoses was 88% (120 kVp) and 84% (100 kVp) and the specificity was 71% (120 kVp) and 74% (100 kVp), respectively. Conclusion: By reduction of tube voltage from 120 to 100 kVp at CCTA, while keeping all other scanning parameters unchanged, the radiation dose to the patient can be almost halved while keeping the diagnostic image quality at a clinically acceptable level.
  •  
7.
  • Shahgaldi, Kambiz, et al. (författare)
  • Transesophageal echocardiography measurements of aortic annulus diameter using biplane mode in patients undergoing transcatheter aortic valve implantation
  • 2013
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 11:1, s. 5-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Aortic stenosis (AS) is a relevant common valve disorder. Severe AS and symptoms and/or left ventricular dysfunction (EF<50%) have the indication for aortic valve replacement (AVR). Majority of the patients with AS are elderly often with co-morbidities and generally have high preoperative risk. Transcatheter aortic valve implantation (TAVI) is offered in this group. Four different sizes of Corevalve prosthesis are available. Correct measurement of aortic size prior to TAVI is of great important to choose the right prosthesis size to avoid among others paravalvular leak or prosthesis patient mismatch. Aim of the study is to assess the aortic annulus diameter in patients undergoing TAVI by biplane (BP) mode using transesophageal echocardiography (TEE) and compare it to two-dimensional (2D) transthoracic echocardiography (TTE) and 2DTEE using three-dimensional (3D) TEE as reference method. Methods: The study population consisted of 50 patients retrospectively (24 men and 26 women, mean age 85 +/- 8 years of age) who all had undergone echocardiography examination prior to TAVI. Results: The mean aortic annulus diameter was 20.4 +/- 2.2 mm with TTE, 22.3 +/- 2.5 mm with 2DTEE, 22.9 +/- 1.9 mm with BP-mode and 23.1 +/- 1.9 mm with 3DTEE. TTE underestimated the mean aortic annulus diameter in comparison to transesophageal imaging modalities (p<0.001). Using 3DTEE, 2% of patients were unsuitable for TAVI due to a too-small AoA (n=1). This figure was similar with BP (4%, n=2; p=1.00) but considerably larger with 2DTTE (36%, n=18; p<0.001) and 2DTEE (12%, n=6; p=0.06). There was a strong correlation between BP-mode and 3DTEE for assessment of aortic annulus diameter (r-value 0.88) with small mean difference (-0.2 +/- 0.9 mm) whereas the other modalities showed larger 95% confidence interval and modest correlation (2DTTE vs. 3DTEE, -6.3 to 0.9 mm, r=0.64 and 2DTEE vs. 3DTEE, -4.8 to 3.2 mm, r=0.61). Conclusion: A multi-dimensional method is preferred to assess aortic annulus diameter in TAVI patients since there is risk of underestimation using single plane. Biplane mode is the method of choice in view of speedy post-processing with no need for expensive dedicated software. Lastly, single plane methods lead to misclassification of patients as unsuitable for TAVI. This may be of major clinical importance.
  •  
8.
  • Tengå, Andreas, 1976- (författare)
  • Thermoelectric Properties of Antimony Based Networks
  • 2010
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • With the retreating sources of carbon based fuels, thermoelectric materials can play an important role in the future of environmentally friendly power generators. Sb based framework have in some cases shown some promising properties as thermoelectric materials. The physical properties may be modified with doping or incorporation of new elements. Zn4Sb3 and Cd4Sb3 are structurally related with a Sb-based network and Zn/Cd occupying the rest of the positions. Both structures undergo order-disorder α–β transition of the Zn/Cd positions, at 254 K and ~355 K respectively. The previously ordered interstitial atoms become distributed in the structure and the two high temperature phases are isostructural (R-3c). Cd4Sb3 was synthesized from melt-quench, flux synthesis with Sn, Bi and In. The syntheses made with In resulted in interstitial-free β-Cd4Sb3 with the composition Cd11.7In1.5Sb10. This compound exhibits no phase transitions until decomposition. ZnSnSb2 and InSb both exhibit the cubic sphalerite structure. ZnSnSb2 is metallic and InSb narrow band-gap semiconductor. Attempts were made to fine-tune the electrical properties by probing the mutual solid solubility range. The formula [ZnSnSb2]x[2(InSb)]1-xSn4 and 04Sb3 by In a novel metastable compound with the composition Zn9Sb6In2 was found. Another novel phase was discovered with the composition Zn5Sb4In2-δ (δ=0.15).  The two phases have the same Sb-framework with a CuAl2 structure. Zn and In arrangements fill the square antiprisms formed by the stacking of 32434 nets in anti configuration. The filling of the antiprisms in the two phases are different, in Zn9Sb6In2 the antiprisms have two filling arrangements, an In or Zn3 triangles. In Zn5Sb4In2-δ the antiprisms are filled with an In and a Zn that occupies a split position to form a hetero-atomic dimers.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8
Typ av publikation
tidskriftsartikel (6)
doktorsavhandling (1)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (6)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Rück, Andreas (5)
Sahlén, Anders (2)
Harnek, Jan (2)
Shahgaldi, Kambiz (2)
Manouras, Aristomeni ... (2)
da Silva, Cristina (2)
visa fler...
Carlbring, Per, 1972 ... (1)
Lidin, Sven (1)
Nilsson, Johan (1)
Andersson, Erik (1)
Ahmed, Ejaz (1)
Beck, Johannes (1)
Daniels, Joerg (1)
Doert, Thomas (1)
Eck, Steffen Jan (1)
Heerwig, Andreas (1)
Isaeva, Anna (1)
Ruck, Michael (1)
Schnelle, Walter (1)
Stankowski, Alexande ... (1)
Brismar, Torkel B. (1)
James, Stefan (1)
Andersson, Gerhard (1)
Ljótsson, Brjánn (1)
Lindefors, Nils (1)
Rück, Christian (1)
Bergström, Jan, 1976 ... (1)
Nyman, Ulf (1)
Ioanes, Dan (1)
Freter, Wolfgang (1)
Karlsson, Andreas (1)
Bäck, Magnus (1)
Melinder, Annika (1)
Cederlund, Kerstin (1)
Andreewitch, Sergej (1)
Settergren, Magnus (1)
Olivecrona, Göran (1)
Winter, Reidar (1)
Nilsson, Tage (1)
Lidin, Sven, Profess ... (1)
Back, Magnus (1)
Zagozdzon, Leszek (1)
Holm, Peter (1)
Ripsweden, Jonaz (1)
Holm, Jon (1)
Mir-Akbari, Habib (1)
Rasmussen, Elsbeth (1)
Tengå, Andreas, 1976 ... (1)
Ruck, Michael, Prof. ... (1)
visa färre...
Lärosäte
Karolinska Institutet (4)
Lunds universitet (3)
Umeå universitet (2)
Kungliga Tekniska Högskolan (2)
Stockholms universitet (2)
Uppsala universitet (1)
visa fler...
Linköpings universitet (1)
Mittuniversitetet (1)
visa färre...
Språk
Engelska (7)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (3)
Naturvetenskap (2)
Teknik (1)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy