SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ruffieux Silvia 1990) srt2:(2020)"

Sökning: WFRF:(Ruffieux Silvia 1990) > (2020)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Trabaldo, Edoardo, 1990, et al. (författare)
  • Properties of grooved Dayem bridge based YBa2Cu3 O 7 - δ superconducting quantum interference devices and magnetometers
  • 2020
  • Ingår i: Applied Physics Letters. - : AIP Publishing. - 0003-6951 .- 1077-3118. ; 116:13
  • Tidskriftsartikel (refereegranskat)abstract
    • The transport properties of a YBa2Cu3 O 7 - δ superconducting quantum interference device (SQUID) based on grooved Dayem bridge weak links are studied as a function of temperature: at high temperatures (60 K < T < T c = 89 K), the weak links show properties similar to superconductor-normal conductor-superconductor junctions, while at temperatures below 60 K, the weak links behave like short Dayem bridges. Using these devices, we have fabricated SQUID magnetometers with galvanically coupled in-plane pickup loops: at T = 77 K, magnetic field white noise levels as low as 63 fT/ Hz have been achieved. © 2020 Author(s).
  •  
2.
  • Andersen, L. M., et al. (författare)
  • On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG
  • 2020
  • Ingår i: NeuroImage. - : Elsevier BV. - 1053-8119 .- 1095-9572. ; 221
  • Tidskriftsartikel (refereegranskat)abstract
    • Magnetoencephalography (MEG) has a unique capacity to resolve the spatio-temporal development of brain activity from non-invasive measurements. Conventional MEG, however, relies on sensors that sample from a distance (20–40 mm) to the head due to thermal insulation requirements (the MEG sensors function at 4 K in a helmet). A gain in signal strength and spatial resolution may be achieved if sensors are moved closer to the head. Here, we report a study comparing measurements from a seven-channel on-scalp SQUID MEG system to those from a conventional (in-helmet) SQUID MEG system. We compared the spatio-temporal resolution between on-scalp and conventional MEG by comparing the discrimination accuracy for neural activity patterns resulting from stimulating five different phalanges of the right hand. Because of proximity and sensor density differences between on-scalp and conventional MEG, we hypothesized that on-scalp MEG would allow for a more high-resolved assessment of these activity patterns, and therefore also a better classification performance in discriminating between neural activations from the different phalanges. We observed that on-scalp MEG provided better classification performance during an early post-stimulus period (10–20 ms). This corresponded to the electroencephalographic (EEG) component P16/N16 and was an unexpected observation as this component is usually not observed in conventional MEG. This finding shows that on-scalp MEG enables a richer registration of the cortical signal, indicating a sensitivity to what are potentially sources in the thalamo-cortical radiation. We had originally expected that on-scalp MEG would provide better classification accuracy based on activity in proximity to the P60m component compared to conventional MEG. This component indeed allowed for the best classification performance for both MEG systems (60–75%, chance 50%). However, we did not find that on-scalp MEG allowed for better classification than conventional MEG at this latency. We suggest that this absence of differences is due to the limited sensor coverage in the recording, in combination with our strategy for positioning the on-scalp MEG sensors. We show how the current sensor coverage may have limited our chances to register the necessary between-phalange source field dissimilarities for fair hypothesis testing, an approach we otherwise believe to be useful for future benchmarking measurements. © 2020 The Authors
  •  
3.
  • Pfeiffer, Christoph, 1989, et al. (författare)
  • A 7-Channel High-T-c SQUID-Based On-Scalp MEG System
  • 2020
  • Ingår i: IEEE Transactions on Biomedical Engineering. - 0018-9294 .- 1558-2531. ; 67:5, s. 1483-1489
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To present the technical design and demonstrate the feasibility of a multi-channel on-scalp magnetoencephalography (MEG) system based on high critical temperature (high-Tc) superconducting quantum interference devices (SQUIDs). Methods: We built a liquid nitrogen-cooled cryostat that houses seven YBCO SQUID magnetometers arranged in a dense, head-aligned array with minimal distance to the room-temperature environment for all sensors. We characterize the performance of this 7-channel system in terms of on-scalp MEG utilization and present recordings of spontaneous and evoked brain activity. Results: The center-to-center spacing between adjacent SQUIDs is 12.0 and 13.4 mm and all SQUIDs are in the range of 1-3 mm of the head surface. The cryostat reaches a base temperature of 70 K and stays cold for >16hwith a single 0.9 L filling. The white noise levels of the magnetometers is 50-130 fT/Hz1/2 at 10 Hz and they show low sensor-tosensor feedback flux crosstalk (<0.6%). We demonstrate evoked fields fromauditory stimuli and single-shot sensitivity to alpha modulation from the visual cortex. Conclusion: All seven channels in the system sensitively sample neuromagnetic fields with mm-scale scalp standoff distances. The hold time of the cryostat furthermore is sufficient for a day of recordings. As such, our multi-channel high-Tc SQUID-based system meets the demands of on-scalp MEG. Significance: The system presented here marks the first high-Tc SQUID-based on-scalp MEG system with more than two channels. It enables us to further explore the benefits of on-scalp MEG in future recordings.
  •  
4.
  • Pfeiffer, Christoph, 1989, et al. (författare)
  • On-scalp MEG sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration
  • 2020
  • Ingår i: Neuroimage. - : Elsevier BV. - 1053-8119 .- 1095-9572. ; 212
  • Tidskriftsartikel (refereegranskat)abstract
    • Source modelling in magnetoencephalography (MEG) requires precise co-registration of the sensor array and the anatomical structure of the measured individual's head. In conventional MEG, the positions and orientations of the sensors relative to each other are fixed and known beforehand, requiring only localization of the head relative to the sensor array. Since the sensors in on-scalp MEG are positioned on the scalp, locations of the individual sensors depend on the subject's head shape and size. The positions and orientations of on-scalp sensors must therefore be measured a every recording. This can be achieved by inverting conventional head localization, localizing the sensors relative to the head - rather than the other way around. In this study we present a practical method for localizing sensors using magnetic dipole-like coils attached to the subject's head. We implement and evaluate the method in a set of on-scalp MEG recordings using a 7-channel on-scalp MEG system based on high critical temperature superconducting quantum interference devices (high-T-c SQUIDs). The method allows individually localizing the sensor positions, orientations, and responsivities with high accuracy using only a short averaging time (<= 2 mm, < 3 degrees and < 3%, respectively, with 1-s averaging), enabling continuous sensor localization. Calibrating and jointly localizing the sensor array can further improve the accuracy of position and orientation (< 1 mm and < 1 degrees, respectively, with 1-s coil recordings). We demonstrate source localization of on-scalp recorded somatosensory evoked activity based on coregistration with our method. Equivalent current dipole fits of the evoked responses corresponded well (within 4.2 mm) with those based on a commercial, whole-head MEG system.
  •  
5.
  • Ruffieux, Silvia, 1990 (författare)
  • High-temperature superconducting magnetometers for on-scalp MEG
  • 2020
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • In the growing field of on-scalp magnetoencephalography (MEG), brain activity is studied by non-invasively mapping the magnetic fields generated by neuronal currents with sensors that are flexibly placed in close proximity to the subject's head. This thesis focuses on high-temperature superconducting magnetometers made from YBa2Cu3Ox-7 (YBCO), which enables a reduction in the sensor-to-room temperature standoff distance from roughly 2 cm (for conventional MEG systems) down to 1 mm. Because of the higher neuromagnetic signal magnitudes available to on-scalp sensors, simulations predict that even a relatively low-sensitivity (higher noise) full-head on-scalp MEG system can extract more information about brain activity than conventional systems. In the first part of this thesis, the development of high critical temperature (high-Tc) superconducting quantum interference device (SQUID) magnetometers for a 7-channel on-scalp MEG system is described. The sensors are single layer magnetometers with a directly coupled pickup loop made on 10 mm × 10 mm substrates using bicrystal grain boundary Josephson junctions. We found that the kinetic inductance strongly varies with film quality and temperature. Determination of all SQUID parameters by combining measurements and inductance simulations led to excellent agreement between experimental results and theoretical predictions. This allowed us to perform an in-depth magnetometer optimization. The best magnetometers achieve a magnetic field noise level of 44 fT/√Hz at 78 K. Fabricated test SQUIDs provide evidence that noise levels below 30 fT/√Hz are possible for high quality junctions with fairly low critical currents and in combination with the optimized pickup loop design. Different feedback methods for operation in a densely-packed on-scalp MEG system were also investigated. Direct injection of current into the SQUID loop was identified as the best on-chip feedback method with feedback flux crosstalk below 0.5%. By reducing the operation temperature, the noise level can be further reduced, however, the effective area also decreases because of the decreasing kinetic inductance contribution. We present a method that allows for one-time sensor calibration independent of temperature. In the second part, the design, operation, and performance of the constructed 7-channel on-scalp MEG system based on the fabricated magnetometers is presented. With a dense (2 mm edge-to-edge) hexagonal head-aligned array, the system achieves a small sensor-to-head standoff distance of 1-3 mm and dense spatial sampling. The magnetic field noise levels are 50-130 fT/√Hz and the sensor-to-sensor feedback flux crosstalk is below 0.6%. MEG measurements with the system demonstrate the feasibility of the approach and indicate that our on-scalp MEG system allows retrieval of information unavailable to conventional MEG. In the third part, two alternative magnetometer types are studied for the next generation system. The first alternative is magnetometers based on Dayem bridge junctions instead of bicrystal grain boundary junctions. With a magnetometer based on the novel grooved Dayem bridge junctions, a magnetic field noise level of 63 fT/√Hz could be achieved, which shows that Dayem bridge junctions are starting to become a viable option for single layer magnetometers. The second alternative are high-Tc SQUID magnetometers with an inductively coupled flux transformer. The best device with bicrystal grain boundary junctions reaches a magnetic field noise level below 11 fT/√Hz and outperforms the best single layer device for frequencies above 20 Hz. In the last part, the potential of kinetic inductance magnetometers (KIMs) is investigated. We demonstrate the first high-Tc KIMs, which can be operated in fields of 9-28 µT and achieve a noise level of 4 pT/√Hz at 10 kHz.
  •  
6.
  •  
7.
  • Westin, Karin, et al. (författare)
  • Detection of interictal epileptiform discharges: A comparison of on-scalp MEG and conventional MEG measurements
  • 2020
  • Ingår i: Clinical Neurophysiology. - : Elsevier BV. - 1872-8952 .- 1388-2457. ; 131:8, s. 1711-1720
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Conventional MEG provides an unsurpassed ability to, non-invasively, detect epileptic activity. However, highly resolved information on small neuronal populations required in epilepsy diagnostics is lost and can be detected only intracranially. Next-generation on-scalp magnetencephalography (MEG) sensors aim to retrieve information unavailable to conventional non-invasive brain imaging techniques. To evaluate the benefits of on-scalp MEG in epilepsy, we performed the first-ever such measurement on an epilepsy patient. Methods: Conducted as a benchmarking study focusing on interictal epileptiform discharge (IED) detectability, an on-scalp high-temperature superconducting quantum interference device magnetometer (high-Tc SQUID) system was compared to a conventional, low-temperature SQUID system. Coregistration of electroencephalopraphy (EEG) was performed. A novel machine learning-based IED-detection algorithm was developed to aid identification of on-scalp MEG unique IEDs. Results: Conventional MEG contained 24 IEDs. On-scalp MEG revealed 47 IEDs (16 co-registered by EEG, 31 unique to the on-scalp MEG recording). Conclusion: Our results indicate that on-scalp MEG might capture IEDs not seen by other non-invasive modalities. Significance: On-scalp MEG has the potential of improving non-invasive epilepsy evaluation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy