  • Rosdahl, Hans, et al. (författare)
  • Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method
  • 2010
  • Ingår i: European Journal of Applied Physiology. - : Springer Science and Business Media LLC. - 1439-6319 .- 1439-6327. ; 109:2, s. 159-171
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to evaluate two versions of the Oxycon Mobile portable metabolic system, (OMPS1 and OMPS2) in a wide range of oxygen uptake, using the Douglas bag method (DBM) as criterion method. The metabolic variables VO2, VCO2, respiratory exchange ratio and VE were measured during submaximal and maximal cycle ergometer exercise with sedentary, moderately trained individuals and athletes as participants. Test-retest reliability was investigated using the OMPS1. The coefficients of variation varied between 2% and 7% for the metabolic parameters measured at different work rates, and resembled those obtained with the DBM. With the OMPS1, systematic errors were found in the determination of VO2 and VCO2. At submaximal work rates VO2 was 6-14% and VCO2 5-9% higher than with the DBM. At VO2max both VO2 and VCO2 were slightly lower as compared to DBM (-4.1% and -2.8% respectively). With OMPS2, VO2 was determined accurately within a wide measurement range (about 1-5.5 L*min-1), while VCO2 was overestimated (3-7%). VE was accurate at submaximal work rates with both OMPS1 and OMPS2, whereas underestimations (4-8%) were noted at VO2max. The present study is the first to demonstrate that a wide range of VO2 can be measured accurately with the Oxycon Mobile portable metabolic system (second generation). Future investigations are suggested to clarify reasons for the small errors noted for VE and VCO2 versus the Douglas bag measurements, and also to gain knowledge of the performance of the device under applied and non-laboratory conditions.
  •  
2.
  •  
3.
  •  
4.
  • Salier Eriksson, Jane, et al. (författare)
  • Validity of the Oxycon Mobile metabolic system under field measuring conditions
  • 2012
  • Ingår i: European Journal of Applied Physiology. - : Springer. - 1439-6319 .- 1439-6327. ; 112:1, s. 345-355
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract Purpose: It is essential to validate portable metabolic systems, not only in laboratory settings, but also in field measuring conditions, such as prolonged moderate exercise at low temperatures, high humidity and with external wind. Methods: VO2, VCO2, RER and VE were measured using the Oxycon Mobile (OM), with a windshield, during cycle ergometer exercise: (I) indoors at three submaximal workloads with no wind or with external wind (13–20 m·s-1) from front, side and back; (II) at two submaximal workloads outdoors (12 ± 2oC; 86 ± 7% RH), with and without a system for drying the ambient air around the air sampling tube; and (III) at one workload outdoors for 45 min (5 ± 4oC; 69 ± 16.5% RH). Any physiological drift was checked for with pre- and postmeasurements by the Douglas bag method (DBM). Results: A minor effect of external wind from behind was noted in RER and VE (-2 and -3%).. The system for drying the ambient air around the gas sampling tube had no effect on the measured levels. A small difference in VCO2 drift between the OM and DBM (1.5 mL·min-2) was noted in the stability test. Conclusion: Heavy external wind applied from different directions generally does not affect the measurements of the OM. Furthermore, when using a unit for drying the ambient air around the gas sampling tube, the OM can accurately measure VO2, RER and VE   at submaximal workloads for at least45 min under challenging conditions with regard to humidity and temperature.  
  •  