SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sartipy U.) srt2:(2020-2024)"

Sökning: WFRF:(Sartipy U.) > (2020-2024)

  • Resultat 1-10 av 57
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Dagnegård, H.H., et al. (författare)
  • Survival after aortic root replacement with a stentless xenograft is determined by patient characteristics
  • 2022
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Mosby Inc.; Elsevier Inc.. - 0022-5223 .- 1097-685X. ; 164:6, s. 1712-1724
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Our objective was to examine intermediate-term survival and reinterventions in unselected patients, stratified according to indication, who received a Freestyle (Medtronic Inc, Minneapolis, Minn) bioprosthesis as a full aortic root replacement. Methods: Data from medical records were retrospectively collected for patients who had aortic root replacement using Freestyle bioprostheses between 1999 and 2018 at 6 North-Atlantic centers. Survival status was extracted from national registries and results stratified according to indication for surgery. Results: We included 1030 implantations in 1008 patients with elective indications for surgery: aneurysm (39.8%), small root (8.3%), and other (13.8%), and urgent/emergent indications: endocarditis (26.7%) and Stanford type A aortic dissection (11.4%). Across indications, 46.3% were nonelective cases and 34.0% were reoperations. Median age was 66.0 (interquartile range, 58.0-71.8) years and median follow-up was 5.0 (interquartile range, 2.6-7.9) years. Thirty-day mortality varied from 2.9% to 27.4% depending on indication. Intermediate survival for 90-day survivors with elective indications were not different from the general population standardized for age and sex (P = .95, 83, and .16 for aneurysms, small roots, and other, respectively). In contrast, patients with endocarditis and type A dissection had excess mortality (P < .001). Freedom from valve reinterventions was 95.0% and 94.4% at 5 and 8 years, respectively. In all, 52 patients (5.2%) underwent reinterventions, most because of endocarditis. Conclusions: At intermediate term follow-up this retrospective study provides further support for the use of the Freestyle bioprosthesis in the real-world setting of diverse, complex, and often high-risk aortic root replacement and suggests that outcome is determined by patient and disease, rather than by prosthesis, characteristics. © 2021 The Authors
  •  
9.
  • Dalen, M, et al. (författare)
  • Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study
  • 2021
  • Ingår i: BMJ open. - : BMJ. - 2044-6055. ; 11:11, s. e047962-
  • Tidskriftsartikel (refereegranskat)abstract
    • Bioprosthetic aortic valves with an extended subannular component, such as transcatheter valves, exert increased compression on the cardiac conduction system and increase the risk for permanent pacemaker implantation. It is unknown if the On-X mechanical prosthetic valve, which has an elongated subannular valve housing, increases the risk of permanent pacemaker implantation following aortic valve replacement.DesignObservational nationwide cohort study.SettingSwedish population-based study.ParticipantsAll patients aged 18–65 years who underwent primary mechanical aortic valve replacement in Sweden between 2005 and 2018. We used the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies register and other Swedish national health-data registers.ExposurePatients implanted with an On-X valve versus patients implanted with other bileaflet mechanical valves.Primary and secondary outcome measuresPrimary outcome measure was permanent pacemaker implantation within 30 days of surgery.ResultsA total of 2602 patients were included, and 581 patients received an On-X valve and 2021 patients received a St Jude Masters/Regent (n=945) or Carbomedics Reduced valve (n=1076). In the total study population, 115 (4.4%) permanent pacemaker implantations were performed within 30 days after aortic valve replacement. In the propensity score matched population, there was no significant difference in the rate of permanent pacemaker implantation in the On-X group compared with the control group: 3.6% (95% CI: 2.4% to 5.5%) vs 4.0% (95% CI: 2.7% to 5.9%), p=0.877.ConclusionsThe On-X prosthetic heart valve was associated with a similarly low risk for permanent pacemaker implantation after aortic valve replacement compared with other conventional bileaflet mechanical valves. The On-X elongated subannular valve housing does not interfere with the cardiac conduction system.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 57

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy