SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Shen Jingchun) srt2:(2011-2014)"

Sökning: WFRF:(Shen Jingchun) > (2011-2014)

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • McKay, James D., et al. (författare)
  • A Genome-Wide Association Study of Upper Aerodigestive Tract Cancers Conducted within the INHANCE Consortium
  • 2011
  • Ingår i: PLOS Genetics. - : Public Library of Science (PLoS). - 1553-7390 .- 1553-7404. ; 7:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Genome-wide association studies (GWAS) have been successful in identifying common genetic variation involved in susceptibility to etiologically complex disease. We conducted a GWAS to identify common genetic variation involved in susceptibility to upper aero-digestive tract (UADT) cancers. Genome-wide genotyping was carried out using the Illumina HumanHap300 beadchips in 2,091 UADT cancer cases and 3,513 controls from two large European multi-centre UADT cancer studies, as well as 4,821 generic controls. The 19 top-ranked variants were investigated further in an additional 6,514 UADT cancer cases and 7,892 controls of European descent from an additional 13 UADT cancer studies participating in the INHANCE consortium. Five common variants presented evidence for significant association in the combined analysis (p <= 5 x 10(-7)). Two novel variants were identified, a 4q21 variant (rs1494961, p = 1 x 10(-8)) located near DNA repair related genes HEL308 and FAM175A (or Abraxas) and a 12q24 variant (rs4767364, p = 2 x 10(-8)) located in an extended linkage disequilibrium region that contains multiple genes including the aldehyde dehydrogenase 2 (ALDH2) gene. Three remaining variants are located in the ADH gene cluster and were identified previously in a candidate gene study involving some of these samples. The association between these three variants and UADT cancers was independently replicated in 5,092 UADT cancer cases and 6,794 controls non-overlapping samples presented here (rs1573496-ADH7, p = 5 x 10(-8); rs1229984-ADH1B, p = 7 x 10(-9); and rs698-ADH1C, p = 0.02). These results implicate two variants at 4q21 and 12q24 and further highlight three ADH variants in UADT cancer susceptibility.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Zhang, Xingxing, et al. (författare)
  • Design, fabrication and experimental study of a solar photovoltaic/loop-heat-pipe based heat pump system
  • 2013
  • Ingår i: Solar Energy. - : Elsevier BV. - 0038-092X .- 1471-1257. ; 97, s. 551-568
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, a novel solar photovoltaic/loop-heat-pipe (PV/LHP) module-based heat pump system was designed and fabricated for both electricity and hot water generation. A coated aluminium-alloy (Al-alloy) sheet was applied as the baseboard of PV cells for enhanced heat dissipation to the surroundings, which was characterised by a series of laboratory-controlled conditions over the conventional Tedlar–Polyester–Tedlar (TPT) baseboard. The whole prototype system was subsequently evaluated in outdoor weather conditions throughout a consecutive period for about one week. Impact of several external parameters to the PV panel with different baseboards was discussed and the results showed that weaker incident radiation, lower air temperature, higher wind speed, and ground mounting solution, were propitious to the PV electrical performance. Given the specific indoor testing conditions, temperature of the Al-alloy based PV cells was observed at about 62.4 °C, which was 5.2 °C lower than that of the TPT based PV cells, and its corresponding PV efficiency was about 9.18%, nearly 0.26% higher than the TPT based type. During the outdoor testing, the mean daily electrical, thermal and overall energetic and exergetic efficiencies of the PV/LHP module were measured at 9.13%, 39.25%, 48.37% and 15.02% respectively. The basic-thermal system performance coefficient (COPth) was found at 5.51 and the advanced system performance coefficient (COPPV/T) was nearly 8.71. A simple comparison was also conducted between the PV/LHP based heat-pump system and those conventional solar/air energy systems, which indicated that this advanced system harvests larger amount of solar energy and therefore enables enhanced solar efficiency and system performance. Basic analysis into the economic and environmental benefits of this prototype system further demonstrated such technology will be competitive in the future energy supply industry with a payback period of 16 (9) years and a life-cycle carbon reduction of 12.06 (2.94) tons in Shanghai (London).
  •  
6.
  • Zhang, Xingxing, et al. (författare)
  • Dynamic performance of a novel solar photovoltaic/loop-heat-pipe heat pump system
  • 2014
  • Ingår i: Applied Energy. - : Elsevier BV. - 0306-2619 .- 1872-9118. ; 114, s. 335-352
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective of the paper is to present an investigation into the dynamic performance of a novel solar photovoltaic/loop-heat-pipe (PV/LHP) heat pump system for potential use in space heating or hot water generation. The methods used include theoretical computer simulation, experimental verification, analysis and comparison. The fundamental equations governing the transient processes of solar transmission, heat transfer, fluid flow and photovoltaic (PV) power generation were appropriately integrated to address the energy balances occurring in different parts of the system, e.g., glazing cover, PV cells, fin sheet, loop heat pipe, heat pump cycle and water tank. A dedicated computer model was developed to resolve the above grouping equations and consequently predict the system’s dynamic performance. An experimental rig was constructed and operated under the real weather conditions for over one week in Shanghai to evaluate the system living performance, which was undertaken by measurement of various operational parameters, e.g., solar radiation, photovoltaic power generation, temperatures and heat pump compressor consumption. On the basis of the first- (energetic) and second- (exergetic) thermodynamic laws, an overall evaluation approach was proposed and applied to conduct both quantitative and qualitative analysis of the PV/LHP module’s efficiency, which involved use of the basic thermal performance coefficient (COPth) and the advanced performance coefficient (COPPV/T) of such a system. Moreover, a simple comparison between the PV/LHP heat-pump system and conventional solar/air energy systems was conducted. The research results indicated that under the testing outdoor conditions, the mean daily electrical, thermal and overall energetic and exergetic efficiencies of the PV/LHP module were 9.13%, 39.25%, 48.37% and 15.02% respectively, and the average values of COPth and COPPV/T were 5.51 and 8.71. The PV/LHP module was found to achieve 3–5% higher solar exergetic efficiency than standard PV systems and about 7% higher overall solar energetic efficiency than the independent solar collector. Compared to the conventional solar/air heat pump systems, the PV/LHP heat pump system could achieve a COP figure that is around 1.5–4 times that for the conventional systems. It is concluded that the computer model is able to achieve a reasonable accuracy in predicting the system’s dynamic performance. The PV/LHP heat pump system is able to harvest significant amount of solar heat and electricity, thus enabling achieving enhanced solar thermal and electrical efficiencies. All these indicate a positive implication that the proposed system has potential to be developed into a high performance PV/T technology that can contribute to significant fossil fuel energy saving and carbon emission.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy