SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Simpson David) srt2:(2000-2004)"

Sökning: WFRF:(Simpson David) > (2000-2004)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adcox, K, et al. (författare)
  • PHENIX detector overview
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Squitieri, Ferdinando, et al. (författare)
  • Homozygosity for CAG mutation in Huntington disease is associated with a more severe clinical course.
  • 2003
  • Ingår i: Brain. - : Oxford University Press (OUP). - 0006-8950 .- 1460-2156. ; 126:Pt 4, s. 946-55
  • Tidskriftsartikel (refereegranskat)abstract
    • Huntington disease is caused by a dominantly transmitted CAG repeat expansion mutation that is believed to confer a toxic gain of function on the mutant protein. Huntington disease patients with two mutant alleles are very rare. In other poly(CAG) diseases such as the dominant ataxias, inheritance of two mutant alleles causes a phenotype more severe than in heterozygotes. In this multicentre study, we sought differences in the disease features between eight homozygotes and 75 heterozygotes for the Huntington disease mutation. We identified subjects homozygous for the Huntington disease mutation by DNA testing and compared their clinical features (age at onset, symptom presentation, disease severity and disease progression) with those of a group of heterozygotes, who were assessed longitudinally. The age at onset of symptoms in the homozygote cases was within the range expected for heterozygotes with the same CAG repeat lengths, whereas homozygotes had a more severe clinical course. The observation of a more rapid decline in motor, cognitive and behavioural symptoms in homozygotes was consistent with the extent of neurodegeneration as available at imaging in three patients, and at the post-mortem neuropathological report in one case. Our analysis suggests that although homozygosity for the Huntington disease mutation does not lower the age at onset of symptoms, it affects the phenotype and the rate of disease progression. These data, once confirmed in a larger series of patients, point to the possibility that the mechanisms underlying age at onset and disease progression in Huntington disease may differ.
  •  
3.
  • Abou-Hachem, Maher, et al. (författare)
  • Calcium binding and thermostability of carbohydrate binding module CBM4-2 of Xyn10A from Rhodothermus marinus.
  • 2002
  • Ingår i: Biochemistry. - : American Chemical Society (ACS). - 0006-2960 .- 1520-4995. ; 41:18, s. 5720-5729
  • Tidskriftsartikel (refereegranskat)abstract
    • Calcium binding to carbohydrate binding module CBM4-2 of xylanase 10A (Xyn10A) from Rhodothermus marinus was explored using calorimetry, NMR, fluorescence, and absorbance spectroscopy. CBM4-2 binds two calcium ions, one with moderate affinity and one with extremely high affinity. The moderate-affinity site has an association constant of (1.3 +/- 0.3) x 10(5) M(-1) and a binding enthalpy DeltaH(a) of -9.3 +/- 0.4 kJ x mol(-1), while the high-affinity site has an association constant of approximately 10(10) M(-1) and a binding enthalpy DeltaH(a) of -40.5 +/- 0.5 kJ x mol(-1). The locations of the binding sites have been identified by NMR and structural homology, and were verified by site-directed mutagenesis. The high-affinity site consists of the side chains of E11 and D160 and backbone carbonyls of E52 and K55, while the moderate-affinity site comprises the side chain of D29 and backbone carbonyls of L21, A22, V25, and W28. The high-affinity site is in a position analogous to the calcium site in CBM4 structures and in a recent CBM22 structure. Binding of calcium increases the unfolding temperature of the protein (T(m)) by approximately 23 degrees C at pH 7.5. No correlation between binding affinity and T(m) change was noted, as each of the two calcium ions contributes almost equally to the increase in unfolding temperature.
  •  
4.
  • Adler, SS, et al. (författare)
  • PHENIX on-line systems
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 560-592
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
5.
  • Karlsson, Per Erik, et al. (författare)
  • Ozone Exposure Indices for ICP-Forest Observation Plots within the Nordic Countries
  • 2002
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Project aims. To develop methods to estimate local ozone exposure indices that could be applied to forest sites n the Nordic countries. The ozone exposure indices under consideraion were 24-h mean ozone concentrations, daylight AOT40 and cumulative ozone uptake to leves and needles
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy