SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sommer P) srt2:(2005-2009)"

Sökning: WFRF:(Sommer P) > (2005-2009)

  • Resultat 1-10 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Aamodt, K., et al. (författare)
  • The ALICE experiment at the CERN LHC
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
3.
  •  
4.
  • Schmid, F., et al. (författare)
  • Bidirectional tensile testing cell for in situ small angle X-ray scattering investigations of soft tissue
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section B. - : Elsevier BV. - 0168-583X .- 1872-9584. ; 246:1, s. 262-268
  • Tidskriftsartikel (refereegranskat)abstract
    • An X-ray cell for the acquisition of one-dimensional mechanical force-displacement diagrams of soft tissue samples has been developed. The combination of X-ray and mechanical data allows new insights into the coupling of the macroscopic behavior and nanoscopic structural changes during the application of load. Two linear mu-translation stages are used to symmetrically - i.e. bidirectionally - stretch the sample. A video-extensometer is installed to record geometrical changes of the sample during measurement which allows to determine true stresses and strains. The sample can be immersed in a liquid and heated. We demonstrate the advantages over common unidirectional tensile testing devices without length measurement systems by comparing different mechanical and diffraction data sets of human arterial tissue.
  •  
5.
  • Schmid, F., et al. (författare)
  • In situ tensile testing of human aortas by time-resolved small-angle X-ray scattering
  • 2005
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 12, s. 727-733
  • Tidskriftsartikel (refereegranskat)abstract
    • The collagen diffraction patterns of human aortas under uniaxial tensile test conditions have been investigated by synchrotron small- angle X- ray scattering. Using a recently designed tensile testing device the orientation and d- spacing of the collagen fibers in the adventitial layer have been measured in situ with the macroscopic force and sample stretching under physiological conditions. The results show a direct relation between the orientation and extension of the collagen fibers on the nanoscopic level and the macroscopic stress and strain. This is attributed first to a straightening, second to a reorientation of the collagen fibers, and third to an uptake of the increasing loads by the collagen fibers.
  •  
6.
  • Wilking, N., et al. (författare)
  • Long-term follow-up of the SBG 9401 study comparing tailored FEC-based therapy versus marrow-supported high-dose therapy
  • 2007
  • Ingår i: Annals of Oncology. - : Elsevier BV. - 0923-7534 .- 1569-8041. ; 18:4, s. 694-700
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The purpose was to investigate adjuvant marrow-supportive high-dose chemotherapy compared with an equitoxicity-tailored comparator arm. Patients and methods: Five hundred and twenty-five women below theage of 60 years with operated high-risk primary breast cancer were randomised to nine cycles of granulocyte colony-stimulating factor supported and individually tailored FEC (5-fluorouracil, epirubicin, cyclophosphamide), (n = 251) or standard FEC followed by marrow-supported high-dose therapy with CTCb (cyclophosphamide, thiotepa, carboplatin) therapy (n = 274), followed by locoregional radiotherapy and tamoxifen for 5 years. Results: There were 104 breast cancer relapses in the tailored FEC group versus 139 in the CTCb group (double triangular method by Whitehead, P = 0.046), with a median follow-up of all included patients of 60.8 months. The event-free survival demonstrated 121 and 150 events in the tailored FEC- and CTCb group, respectively [P = 0.074, hazard ratio (HR) 0.804, 95% confidence interval (CI) 0.633-1.022]. Ten patients in the tailored FEC regimen developed acute myeloid leukaemia (AML)/myelodysplasia (MDS). One hundred deaths occurred in the tailored FEC group and 121 in the CTCb group (P = 0.287, HR 0.866, 95% CI 0.665-1.129). Conclusion: The update of this study shows an improved outcome linked to the tailored FEC treatment in relation to breast cancer relapse, but also an increased incidence of AML/MDS. © 2007 Oxford University Press.
  •  
7.
  • Beers, Timothy C., et al. (författare)
  • Broadband UBVRCIC photometry of horizontal-branch and metal-poor candidates from the HK and Hamburg/ESO surveys. I.
  • 2007
  • Ingår i: Astrophysical Journal Supplement Series. - : American Astronomical Society. - 0067-0049 .- 1538-4365. ; 168:1, s. 128-139
  • Tidskriftsartikel (refereegranskat)abstract
    • We report broadband UBV and/or BVRCIC CCD photometry for a total of 1857 stars in the thick-disk and halo populations of the Galaxy. The majority of our targets were selected as candidate field horizontal-branch or other A-type stars (FHB/ A, N = 576), or candidate low-metallicity stars (N = 1221), from the HK and Hamburg/ESO objective-prism surveys. Similar data for a small number of additional stars from other samples are also reported. These data are being used for several purposes. In the case of the FHB/ A candidates they are used to accurately separate the lower gravity FHB stars from various higher gravity A-type stars, a subsample that includes the so-called blue metal poor stars, halo and thick-disk blue stragglers, main-sequence A-type dwarfs, and Am and Ap stars. These data are also being used to derive photometric distance estimates to high-velocity hydrogen clouds in the Galaxy and for improved measurements of the mass of the Galaxy. Photometric data for the metal-poor candidates are being used to refine estimates of stellar metallicity for objects with available medium-resolution spectroscopy, to obtain distance estimates for kinematic analyses, and to establish initial estimates of effective temperature for analysis of high-resolution spectroscopy of the stars for which this information now exists.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy