SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Stahlberg J.) srt2:(2020-2023)"

Sökning: WFRF:(Stahlberg J.) > (2020-2023)

  • Resultat 1-10 av 14
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abdelhameed, A. H., et al. (författare)
  • Cryogenic characterization of a LiAlO2 crystal and new results on spin-dependent dark matter interactions with ordinary matter: CRESST Collaboration
  • 2020
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 80:9
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, a first cryogenic characterization of a scintillating LiAlO2 single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut fur Kristallzuchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO2 at cryogenic temperatures. The second achieved an energy threshold of (213.02 +/- 1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c2 and 1.50 GeV/c2. Secondly, a detector module with a 373 g LiAlO2 crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.
  •  
2.
  • Bertoldo, E., et al. (författare)
  • Lithium-Containing Crystals for Light Dark Matter Search Experiments
  • 2020
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 199:1-2, s. 510-518
  • Tidskriftsartikel (refereegranskat)abstract
    • In the current direct dark matter search landscape, the leading experiments in the sub-GeV mass region mostly rely on cryogenic techniques which employ crystalline targets. One attractive type of crystals for these experiments is those containing lithium, due to the fact that 7Li is an ideal candidate to study spin-dependent dark matter interactions in the low mass region. Furthermore, 6Li can absorb neutrons, a challenging background for dark matter experiments, through a distinctive signature which allows the monitoring of the neutron flux directly on site. In this work, we show the results obtained with three different detectors based on LiAlO 2, a target crystal never used before in cryogenic experiments.
  •  
3.
  • Kluck, H., et al. (författare)
  • Latest results of CRESST-III's search for sub-GeV/c(2) dark matter
  • 2020
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6596 .- 1742-6588. ; 1468:1
  • Konferensbidrag (refereegranskat)abstract
    • The CRESST-III experiment searches for direct interactions of dark matter with ordinary matter. The main event signature would be a nuclear recoil inside one of the scintillating CaWO4 crystals. Operating the crystals as cryogenic calorimeters provides a phonon signal as measure of the deposited energy. The simultaneous readout of both signals is used to actively discriminate backgrounds. CRESST-III focuses on the sub-GeV/c(2) mass region where the sensitivity is driven by the threshold. In the first data taking campaign of CRESST-III from 2016-2018 an unprecedented low threshold of 30.1 eV for nuclear recoils was obtained. In this contribution, we will report the status of the experiment and the latest results. [GRAPHICS]
  •  
4.
  • Mancuso, M., et al. (författare)
  • Searches for Light Dark Matter with the CRESST-III Experiment
  • 2020
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 199:1-2, s. 547-555
  • Tidskriftsartikel (refereegranskat)abstract
    • Cryogenic Rare Event Search with Superconducting Thermometers (CRESST) is a long-standing direct dark matter detection experiment with cryogenic detectors located at the underground facility Laboratori Nazionali del Gran Sasso in Italy. CRESST-III, the third generation of CRESST, was specifically designed to have a world-leading sensitivity for low-mass dark matter (DM) (less than 2 GeV/c 2) to probe the spin-independent DM-nucleus cross section. At present, a large part of the parameter space for spin-independent scattering off nuclei remains untested for dark matter particles with masses below few GeV/c 2 although many motivated theoretical models having been proposed. The CRESST-III experiment employs scintillating CaWO 4 crystals of ∼ 25 g as target material for dark matter interactions operated as cryogenic scintillating calorimeters at ∼ 10 mK. CRESST-III first data taking was successfully completed in 2018, achieving an unprecedented energy threshold for nuclear recoils. This result extended the present sensitivity to DM particles as light as ∼ 160 MeV/c 2. In this paper, an overview of the CRESST-III detectors and results will be presented.
  •  
5.
  •  
6.
  •  
7.
  • Kjellberg, A, et al. (författare)
  • Hyperbaric oxygen for treatment of long COVID-19 syndrome (HOT-LoCO): protocol for a randomised, placebo-controlled, double-blind, phase II clinical trial
  • 2022
  • Ingår i: BMJ open. - : BMJ. - 2044-6055. ; 12:11, s. e061870-
  • Tidskriftsartikel (refereegranskat)abstract
    • Long COVID-19, where symptoms persist 12 weeks after the initial SARS-CoV-2-infection, is a substantial problem for individuals and society in the surge of the pandemic. Common symptoms are fatigue, postexertional malaise and cognitive dysfunction. There is currently no effective treatment and the underlying mechanisms are unknown, although several hypotheses exist, with chronic inflammation as a common denominator. In prospective studies, hyperbaric oxygen therapy (HBOT) has been suggested to be effective for the treatment of similar syndromes such as chronic fatigue syndrome and fibromyalgia. A case series has suggested positive effects of HBOT in long COVID-19. This randomised, placebo-controlled clinical trial will explore HBOT as a potential treatment for long COVID-19. The primary objective is to evaluate if HBOT improves health-related quality of life (HRQoL) for patients with long COVID-19 compared with placebo/sham. The main secondary objective is to evaluate whether HBOT improves endothelial function, objective physical performance and short-term HRQoL.Methods and analysisA randomised, placebo-controlled, double-blind, phase II clinical trial in 80 previously healthy subjects debilitated due to long COVID-19, with low HRQoL. Clinical data, HRQoL questionnaires, blood samples, objective tests and activity metre data will be collected at baseline. Subjects will be randomised to a maximum of 10 treatments with hyperbaric oxygen or sham treatment over 6 weeks. Assessments for safety and efficacy will be performed at 6, 13, 26 and 52 weeks, with the primary endpoint (physical domains in RAND 36-Item Health Survey) and main secondary endpoints defined at 13 weeks after baseline. Data will be reviewed by an independent data safety monitoring board.Ethics and disseminationThe trial is approved by the Swedish National Institutional Review Board (2021–02634) and the Swedish Medical Products Agency (5.1-2020-36673). Positive, negative and inconclusive results will be published in peer-reviewed scientific journals with open access.Trial registration numberNCT04842448.
  •  
8.
  •  
9.
  • Angloher, G., et al. (författare)
  • COSINUS: Cryogenic Calorimeters for the Direct Dark Matter Search with NaI Crystals
  • 2020
  • Ingår i: Journal of Low Temperature Physics. - : Springer Science and Business Media LLC. - 0022-2291 .- 1573-7357. ; 200:5-6, s. 428-436
  • Tidskriftsartikel (refereegranskat)abstract
    • COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) is an experiment employing cryogenic calorimeters, dedicated to direct dark matter search in underground laboratories. Its goal is to cross-check the annual modulation signal the DAMA collaboration has been detecting for about 20 years (Bernabei et al. in Nucl Part Phys Proc 303-305:74-79, 2018. 10.1016/j.nuclphysbps.2019.03.015) and which has been ruled out by other experiments in certain dark matter scenarios. COSINUS can provide a model-independent test by the use of the same target material (NaI), with the additional chance of discriminating beta/gamma events from nuclear recoils on an event-by-event basis, by the application of a well-established temperature sensor technology developed within the CRESST collaboration. Each module is constituted by two detectors: the light detector, that is a silicon beaker equipped with a transition edge sensor (TES), and the phonon detector, a small cubic NaI crystal interfaced with a carrier of a harder material (e.g. CdWO4), also instrumented with a TES. This technology had so far never been applied to NaI crystals because of several well-known obstacles, and COSINUS is the first experiment which succeeded in operating NaI crystals as cryogenic calorimeters. Here, we present the COSINUS project, describe the achievements and the challenges of the COSINUS prototype development and discuss the status and the perspectives of this NaI-based cryogenic frontier.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 14

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy