  • Results of an International Comparison of Instrument Current Transformers up to 10 kA at 50 Hz Frequency
  • 2018
  • Ingår i: CPEM 2018 - Conference on Precision Electromagnetic Measurements. - 9781538609736
  • Konferensbidrag (refereegranskat)abstract
    • Traceability of the current ratio is crucial for the measurement of electrical energy in revenue metering. A comparison of the AC current ratio was therefore performed within EURAMET in the time period 2012-2016, using a precision CT as the traveling device. The Czech Metrology Institute (CMI) as coordinator processed the measurement results of the 15 European participating laboratories. The comparison of the results for transformer ratios of (4, 5, 6, 8, 10) kA 5 A at 15 VA burden and (4 and 10) kA 5 A ratios at 5 VA burden indicates good agreement between the participating laboratories. The main differences are found for phase displacement, at least in part due to instability of the traveling standard. .
  •  
4.
  • Draxler, K., et al. (författare)
  • International comparison of current transformer calibration systems up to 10 kA at 50 Hz frequency
  • 2016
  • Ingår i: 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016). - 9781467391344
  • Konferensbidrag (refereegranskat)abstract
    • Current transformers (CTs) are precision devices that scale high currents down to values that can be easily handled by measurement equipment. To support CT applications in revenue metering, a comparison on AC current transformer calibration systems was performed among 15 European national metrology institutes using a precision CT as the travelling device. The first comparison results for the transformation ratios (4, 5, 6, 8, 10) kA/5 A of the travelling CT at nominal burden of 5 VA and 15 VA indicate good agreement between the participating laboratories. The main differences are found for phase displacement, at least partly caused by the instability of the traveling standard.
  •  
5.
  • Hallstrom, J., et al. (författare)
  • Performance of a modular wideband 1000 kV HVDC reference divider
  • 2014
  • Ingår i: CPEM Digest (Conference on Precision Electromagnetic Measurements). - 9781479952052 ; , s. 782-783
  • Konferensbidrag (refereegranskat)abstract
    • This paper describes the performance of a wideband HVDC reference divider. The divider concept is a shielded modular divider and it is intended for traceable calibration of HVDC measuring systems up to 1000 kV in customers' laboratories. The first priority in the design was the accuracy of HVDC measurements. In addition, the divider was designed to have wide bandwidth, both to enable measurement of ripple voltages and to prevent damage during possible flashovers. © 2014 IEEE.
  •  
6.
  •  
7.
  •  
8.
  • Bergman, Anders, et al. (författare)
  • Intercomparison of AC peak voltage measurement
  • 1999
  • Ingår i: IEE Conference Publication. - : IEE. - 0852967195 ; , s. 1.9.S1-1.12.S1
  • Konferensbidrag (refereegranskat)abstract
    • An intercomparison on the measurement of high voltage peak value has been carried out between the National Metrology Institutes of Sweden and Germany in 1995 and between Finland and Sweden in 1996. The results show a very satisfactory agreement between the participants. It seems that part of the discrepancies found may be due to the loose definition of peak voltage in IEC 60060-1.
  •  
9.
  •  
10.
  • Naukkarinen, J., et al. (författare)
  • Characterising metabolically healthy obesity in weight-discordant monozygotic twins
  • 2014
  • Ingår i: Diabetologia. - New York, USA : Springer. - 0012-186X .- 1432-0428. ; 57:1, s. 167-176
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims/hypothesis: Not all obese individuals display the metabolic disturbances commonly associated with excess fat accumulation. Mechanisms maintaining this ‘metabolically healthy obesity’ (MHO) are as yet unknown. We aimed to study different fat depots and transcriptional pathways in subcutaneous adipose tissue (SAT) as related to the MHO phenomenon.Methods: Sixteen rare young adult obesity-discordant monozygotic (MZ) twin pairs (intra-pair difference (∆) in BMI ≥3 kg/m2), aged 22.8–35.8 years, were examined for detailed characteristics of metabolic health (subcutaneous, intra-abdominal and liver fat [magnetic resonance imaging/spectroscopy]), OGTT, lipids, adipokines and C-reactive protein (CRP). Affymetrix U133 Plus 2.0 chips were used to analyse transcriptomics pathways related to mitochondrial function and inflammation in SAT.Results: Based on liver fat accumulation, two metabolically different subgroups emerged. In half (8/16) of the pairs (∆weight 17.1 ± 2.0 kg), the obese co-twin had significantly higher liver fat (∆718%), 78% increase in AUC insulin during OGTT and CRP, significantly more disturbance in the lipid profile and greater tendency for hypertension compared with the lean co-twin. In these obese co-twins, SAT expression of mitochondrial oxidative phosphorylation, branched-chain amino acid catabolism, fatty acid oxidation and adipocyte differentiation pathways were downregulated and chronic inflammation upregulated. In the other eight pairs (∆weight 17.4 ± 2.8 kg), the obese co-twin did not differ from the non-obese co-twin in liver fat (∆8%), insulin sensitivity, CRP, lipids, blood pressure or SAT transcriptomics.Conclusions/interpretation: Our results suggest that maintenance of high mitochondrial transcription and lack of inflammation in SAT are associated with low liver fat and MHO.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy