SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Swain M) srt2:(2005-2009)"

Sökning: WFRF:(Swain M) > (2005-2009)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Lima, Estevao, et al. (författare)
  • Endoscopic closure of transmural bladder wall perforations.
  • 2009
  • Ingår i: European urology. - : Elsevier BV. - 1873-7560 .- 0302-2838. ; 56:1, s. 151-7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Traditionally, intraperitoneal bladder perforations caused by trauma or iatrogenic interventions have been treated by open or laparoscopic surgery. Additionally, transvesical access to the peritoneal cavity has been reported to be feasible and useful for natural orifice translumenal endoscopic surgery (NOTES) but would be enhanced by a reliable method of closing the vesicotomy. OBJECTIVE: To assess the feasibility and safety of an endoscopic closure method for vesical perforations using a flexible, small-diameter endoscopic suturing kit in a survival porcine model. DESIGN, SETTING, AND PARTICIPANTS: This pilot study was performed at the University of Minho, Braga, Portugal, using six anesthetized female pigs. INTERVENTIONS: Closure of a full-thickness longitudinal incision in the bladder dome (up to 10 mm in four animals and up to 20 mm in two animals) with the endoscopic suturing kit using one to three absorbable stitches. MEASUREMENTS: The acute quality of sealing was immediately tested by distending the bladder with methylene-blue dye under laparoscopic control (in two animals). Without a bladder catheter, the animals were monitored daily for 2 wk, and a necropsy examination was performed to check for the signs of peritonitis, wound dehiscence, and quality of healing. RESULTS AND LIMITATIONS: Endoscopic closure of bladder perforation was carried out easily and quickly in all animals. The laparoscopic view revealed no acute leak of methylene-blue dye after distension of the bladder. After recovery from anaesthesia, the pigs began to void normally, and no adverse event occurred. Postmortem examination revealed complete healing of vesical incision with no signs of infection or adhesions in the peritoneal cavity. No limitations have yet been studied clinically. CONCLUSIONS: This study demonstrates the feasibility and the safety of endoscopic closure of vesical perforations with an endoscopic suturing kit in a survival porcine model. This study provides support for further studies using endoscopic closure of the bladder which may lead to a new era in management of bladder rupture and adoption of the transvesical port in NOTES procedures.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy