SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Szczesniak D) srt2:(2006-2009)"

Sökning: WFRF:(Szczesniak D) > (2006-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gierlik, M., et al. (författare)
  • Comparative study of large NaI(Tl) and BGO scintillators for the EURopean Illicit TRAfficking Countermeasures Kit project
  • 2006
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 53:3, s. 1737-1743
  • Tidskriftsartikel (refereegranskat)abstract
    • The Tagged Neutron Inspection System, which is the principle of the EURITRACK project, requires efficient and inexpensive gamma-ray detectors. For this purpose, properties of 3 x 3 and 5 x 5 cylindrical BGO and NaI(TI) scintillators and of a 5 x 5 x 10 rectangular NaI(TI) scintillator were determined. 14 Light yield, energy and time resolution of the investigated crystals at the energy of few MeVs of gamma-rays are emphasized. Additionally, the crystals efficiencies calculated with Monte Carlo simulations are compared to peak-to-total ratios obtained experimentally for various combinations of PMTs and the scintillators.
  •  
2.
  •  
3.
  • Swiderski, L., et al. (författare)
  • Boron-10 loaded BC523A liquid scintillator for neutron detection in the border monitoring
  • 2007
  • Ingår i: 2007 IEEE Nuclear Science Symposium & Medical Imaging Conference. - : IEEE. - 1424409233 - 9781424409235 ; , s. 1389-1395
  • Konferensbidrag (refereegranskat)abstract
    • A BC523A liquid scintillator loaded with boron-10 was tested as a detector for both fast and thermal neutrons. Pulse shape discrimination (PSD) method based on a zero-crossing principle was applied to distinguish between neutron and gamma radiation. High quantum efficiency Photonis XP5500B photomultiplier was used to enhance light detection from the scintillator. This allowed a good registration of the energy spectrum of neutron capture events on boron-10, corresponding to about 60 keVee. The applied PSD method proved to be useful for n/γ discrimination. A good resolving power of the method was achieved even without gating on neutron capture events. A comparison with a standard BC501A liquid scintillator was done to evaluate thermal neutrons detection efficiency in BC523A.
  •  
4.
  • Swiderski, L., et al. (författare)
  • Boron-10 Loaded BC523A Liquid Scintillator for Neutron Detection in the Border Monitoring
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 55:6, s. 3710-3716
  • Tidskriftsartikel (refereegranskat)abstract
    • A BC523A liquid scintillator loaded with boron-10 was tested as a detector for both fast and thermal neutrons. A pulse shape discrimination (PSD) method based on a zero-crossing principle was applied to distinguish between neutron and gamma radiation. High quantum efficiency Photonis XP5500B photomultiplier was used to enhance light detection from the scintillator. This allowed a good registration of the energy spectrum of neutron capture events on boron-10, corresponding to about 60 keV gamma-rays. The applied PSD method proved to be useful for n/gamma discrimination. A good resolving power of the method was achieved even without gating on neutron capture events. A comparison with a standard BC501A liquid scintillator was done to evaluate thermal neutrons detection efficiency in BC523A.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy