SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tamburro Davide) srt2:(2005-2009)"

Sökning: WFRF:(Tamburro Davide) > (2005-2009)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Fredolino, C, et al. (författare)
  • Nanoparticles technology : Amplifying the effective sensitivity of biomarker detection to create a urine test for hGH
  • 2009
  • Ingår i: Drug Test Analysis. - 1942-7611. ; 1:9-10, s. 447-454
  • Tidskriftsartikel (refereegranskat)abstract
    • Several clinical-grade immunoassays exist for the specific measurement of hGH or its isoforms in blood but there is an urgent need to apply these same reliable assays to the measurement of hGH in urine as a preferred 'non-invasive' biofluid. Unfortunately, conventional hGH immunoassays cannot attain the sensitivity required to detect the low concentrations of hGH in urine. The lowest limit of sensitivity for existing hGH immunoassays is >50 pg/mL, while the estimated concentration of urinary hGH is about 1 pg/m-50 times lower than the sensitivity threshold. We have created novel N-isopropylacrylamide (NIPAm)-based hydrogel nanoparticles functionalized with an affinity bait. When introduced into an analyte-containing solution, the nanoparticles can perform, in one step, (1) complete harvesting of all solution phase target analytes, (2) full protection of the captured analyte from degradation and (3) sequestration of the analyte, effectively increasing the analyte concentration up to a hundredfold. N-isopropylacrylamide nanoparticles functionalized with Cibacron Blue F3GA bait have been applied to raise the concentration of urinary hGH into the linear range of clinical grade immunoassays. This technology now provides an opportunity to evaluate the concentration of hGH in urine with high precision and accuracy
  •  
2.
  • Tollbäck, Johanna, et al. (författare)
  • Air sampling with Empore solid phase extraction membranes and online single-channel desorption/liquid chromatography/mass spectrometry analysis : Determination of volatile and semi-volatile organophosphate esters
  • 2006
  • Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1129:1, s. 1-8
  • Tidskriftsartikel (refereegranskat)abstract
    • A method for determining organophosphate esters in air samples using C8 Empore solid phase extraction (SPE) membranes has been developed. After the sampling the analytes trapped in the membrane are completely desorbed with methanol, using an extraction cell connected online to the organic modifier channel of a HPLC gradient pump. The addition of water to the mobile phase prior to analytical chromatography ensures that the analytes are refocused and efficiently separated. Sampling with Empore SPE membranes enables the collection of analytes in both the vapour phase and particulate matter. During the air sampling procedure no losses were observed after 24 h of sampling, yielding a total volume of 14.4 m3, even for the most volatile compound used in this investigation (trimethylphosphate). Complete desorption was observed for all the organophosphate esters and recoveries were greater than 95%, with a relative standard deviation of less than 8%. The limits of detection ranged between 0.4 and 19 pg/m3. The effect of particulate matter on the extraction efficiency was investigated in detail by spiking the membranes with reference standard material. It was also found that the SPE membranes could be stored for at least 5 days at room temperature without any evidence of loss. The efficacy of the method was verified using real samples from different common indoor environments. Interestingly, significant quantities of several phosphate esters were found in a NIST standard reference material (urban dust, SRM 1649a).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy