SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tan H. H.) srt2:(2005-2009)"

Sökning: WFRF:(Tan H. H.) > (2005-2009)

  • Resultat 1-10 av 30
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aamodt, K., et al. (författare)
  • The ALICE experiment at the CERN LHC
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Forskningsöversikt (refereegranskat)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
2.
  • Ablikim, M., et al. (författare)
  • Measurements of (XcJ)-> K+K-K+K- decays
  • 2006
  • Ingår i: Physics Letters B. - : Elsevier BV. - 0370-2693 .- 1873-2445. ; 642:3, s. 197-202
  • Tidskriftsartikel (refereegranskat)abstract
    • Using 14M psi(2S) events taken with the BESII detector, chi(cJ) -> 2(K+K-) decays are studied. For the four-kaon final state, the branching fractions are B(chi(c0,1,2) ->.2(K+K-)) = (3.48 +/- 0.23 +/- 0.47) x 10(-3), (0.70 +/- 0.13 +/- 0.10) x 10(-3), and (2.17 +/- 0.20 +/- 0.31) x 10(-3). For the phi K+K- final state, the branching fractions, which are measured for the first time, are B(chi(c0,1,2) -> phi K+K-) = (1.03 +/- 0.22 +/- 0.15) x 10(-3), (0.46 +/- 0.16 +/- 0.06) x 10(-3), and (1.67 +/- 0.26 +/- 0.24) x 10(-4). For the phi phi final state, B(chi(c0,2) -> phi phi) = (0.94 +/- 0.21 +/- 0.13) x 10(-3) and (1.70 +/- 0.30 +/- 0.25) x 10(-3).
  •  
3.
  •  
4.
  • Carninci, P, et al. (författare)
  • The transcriptional landscape of the mammalian genome
  • 2005
  • Ingår i: Science (New York, N.Y.). - : American Association for the Advancement of Science (AAAS). - 1095-9203 .- 0036-8075. ; 309:5740, s. 1559-1563
  • Tidskriftsartikel (refereegranskat)abstract
    • This study describes comprehensive polling of transcription start and termination sites and analysis of previously unidentified full-length complementary DNAs derived from the mouse genome. We identify the 5′ and 3′ boundaries of 181,047 transcripts with extensive variation in transcripts arising from alternative promoter usage, splicing, and polyadenylation. There are 16,247 new mouse protein-coding transcripts, including 5154 encoding previously unidentified proteins. Genomic mapping of the transcriptome reveals transcriptional forests, with overlapping transcription on both strands, separated by deserts in which few transcripts are observed. The data provide a comprehensive platform for the comparative analysis of mammalian transcriptional regulation in differentiation and development.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Deuling, J H H, et al. (författare)
  • Closure of the femoral artery after cardiac catheterization : a comparison of Angio-Seal, StarClose, and manual compression.
  • 2008
  • Ingår i: Catheterization and cardiovascular interventions. - : Wiley. - 1522-1946 .- 1522-726X. ; 71:4, s. 518-23
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To compare Angio-Seal (AS) and StarClose (SC) and manual compression (MC) on efficacy of hemostasis, complication rate, safety of early mobilization, and patient comfort. BACKGROUND: Closure of the femoral artery after cardiac catheterization can be obtained through different methods. Today, physicians can choose from a number of different devices to achieve arterial closure. METHODS: In a prospective trial 450 patients were randomized to AS, SC, or MC. Patients were mobilized 1 to 2 hr after device placement, and 6 hr after MC. Data were collected during hospital admission and by telephone at one month after hospital discharge. RESULTS: Devices were used in 138/150 allocated to AS and 124/150 allocated to SC patients (92% vs. 83%, P = 0.015) Patients with MC experienced more pain during sheath removal than patients receiving a device, and rated their period of bed rest as less comfortable. Oozing and need for pressure bandage at the puncture site were observed in 37 AS patients and 57 SC patients (25% vs. 38%, P = 0.002). Hematoma occurred in 15 AS patients, in 17 SC patients, and in 14 MC patients (11 vs. 14 vs. 9%, ns). CONCLUSION: There is no difference in safety between the three methods of arterial closure. SC was more often not used or successfully deployed. SC patients more often had continuing oozing. On patient comfort, closure devices performed better than MC. Early ambulation in patients with a closure device is safe. AS is the preferred method of arterial closure after cardiac catheterization.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 30

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy