SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tardocchi Marco) "

Sökning: WFRF:(Tardocchi Marco)

  • Resultat 1-10 av 70
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersson Sundén, Erik, et al. (författare)
  • Evaluation of neutron spectrometer techniques for ITER using synthetic data
  • 2013
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 701, s. 62-71
  • Tidskriftsartikel (refereegranskat)abstract
    • A neutron spectrometer at ITER is expected to provide estimates of plasma parameters such as ion temperature, Ti, fuel ion ratio, nt/nd, and Qthermal/Qtot, with 10-20% precision at a time resolution, Δt, of at least 100 ms. The present paper describes a method for evaluating different neutron spectroscopy techniques based on their instrumental response functions and synthetic measurement data. We include five different neutron spectrometric techniques with realistic response functions, based on simulations and measurements where available. The techniques are magnetic proton recoil, thin-foil proton recoil, gamma discriminating organic scintillator, diamond and time-of-flight. The reference position and line of sight of a high resolution neutron spectrometer on ITER are used in the study. ITER plasma conditions are simulated for realistic operating scenarios. The ITER conditions evaluated are beam and radio frequency heated and thermal deuterium-tritium plasmas. Results are given for each technique in terms of the estimated time resolution at which the parameter determination can be made within the required precision (here 10% for Ti and the relative intensities of NB and RF emission components). It is shown that under the assumptions made, the thin-foil techniques out-perform the other spectroscopy techniques in practically all measurement situations. For thermal conditions, the range of achieved Δt in the determination of Ti varies in time scales from ms (for the magnetic and thin-foil proton recoil) to s (for gamma discriminating organic scintillator).
  •  
2.
  •  
3.
  • Gatu Johnson, Maria, 1978-, et al. (författare)
  • Neutron emission from beryllium reactions in JET deuterium plasmas with 3He minority
  • 2010
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 50:4, s. 045005-
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent fast ion studies at JET involve ion cyclotron resonance frequency (ICRF) heating tuned to minority He-3 in cold deuterium plasmas, with beryllium evaporation in the vessel prior to the session. During the experiments, the high-resolution neutron spectrometer TOFOR was used to study the energy spectrum of emitted neutrons. Neutrons of energies up to 10MeV, not consistent with the neutron energy spectrum expected from d(d,n)He-3 reactions, were observed. In this paper, we interpret these neutrons as a first-time observation of a Be-9(He-3, n)C-11 neutron spectrum in a tokamak plasma, a conclusion based on a consistent analysis of experimental data and Monte Carlo simulations. Be-9(a, n)C-12 and Be-9(p, n)B-9 reactions are also simulated for p and a fusion products from d(He-3, a) p reactions; these two-step processes are seen to contribute on a level of about 10% of the single-step process in Be-9(He-3, n) C-11. Contributions to the total neutron yield from the Be-9(3He, n)C-11 reaction are found to be in the range 13 +/- 3 to 57 +/- 5%. We demonstrate how TOFOR can be used to simultaneously (i) probe the deuterium distribution, providing reliable measurements of the bulk deuterium temperature, here in the range 3.2 +/- 0.4 to 6.3 +/- 1.0 keV and (ii) provide an estimate of the beryllium concentration (in the range 0.48 +/- 0.17 to 6.4 +/- 1.7% of n(e) assuming T-3He = 300 keV). The observation of Be-9 related neutrons is relevant in view of the upcoming installation of a beryllium-coated ITER-like wall on JET and for ITER itself. An important implication is possible neutron-induced activation of the ITER vessel during the low-activation phase with ICRF heating tuned to minority He-3 in hydrogen plasmas.
  •  
4.
  • Gatu Johnson, Maria, 1978-, et al. (författare)
  • Neutron emission levels during the ITER zero activation phase
  • 2010
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 50:8, s. 084020-
  • Tidskriftsartikel (refereegranskat)abstract
    • In recent experiments at JET, a contribution to the neutron emission from reactions between beryllium and 3He, 4He and H has been identified. With the beryllium walled planned for ITER, this raises the question of possible neutron activation during the ITER zero activation phase. Here, we estimate the neutron emission rates for various heating scenarios foreseen for this ITER phase using Monte Carlo simulations. The emission is seen to be strongly dependent on the scenario chosen and the assumptions involved. We find that fundamental minority heating can contribute on the scale of low temperature deuterium plasmas, depending on minority concentration and ICRH power applied. Harmonic ICRH leads to production of tails that can give rise to significant neutron emission rates, while rates from hydrogen beams will be near zero. Better knowledge of the zero activation phase conditions, and more sophisticated ICRH codes, would be needed to give exact rate predictions. We conclude that rates from so-called zero activation plasmas will be significantly lower than expected for the DD or DT phases, but far from zero.
  •  
5.
  •  
6.
  • Sjöstrand, Henrik, et al. (författare)
  • Fusion Power Measurement using a Combined Neutron Spectrometer-Camera System at JET
  • 2010
  • Ingår i: Fusion science and technology. - 1536-1055 .- 1943-7641. ; 57:2, s. 162-175
  • Tidskriftsartikel (refereegranskat)abstract
    • Fusion power production is the ultimate goal of fusion research, and its determination is crucial in any fusion energy application. In this paper the principles of collimated neutron flux measurements for fusion plasma power determination are described. In this method, a high-resolution neutron spectrometer provides an absolutely calibrated neutron flux, and a neutron profile monitor ("camera") gives information on the neutron emission profile of the plasma. The total neutron flux seen by the spectrometer is discussed in terms of direct and scattered flux, and a model is set up to evaluate the magnitude of these different components. Particular care is taken to estimate the uncertainties involved, both in the model and the measurements. The method is put to practical use at JET, where a magnetic proton recoil spectrometer and a neutron profile monitor are available. Results from JET's trace tritium experimental campaign in 2003 are presented and show that the systematic uncertainties in fusion power measurements are reduced in comparison to what has been presented for foil activation systems. A systematic error of 6% is reported here. For ITER these results imply that the fusion power can be redundantly measured and with better accuracies than for traditional methods.
  •  
7.
  • Albani, Giorgia, et al. (författare)
  • Evolution in boron-based GEM detectors for diffraction measurements : From planar to 3D converters
  • 2016
  • Ingår i: Measurement science and technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 27:11
  • Tidskriftsartikel (refereegranskat)abstract
    • The so-called '3He-crisis' has motivated the neutron detector community to undertake an intense R&D programme in order to develop technologies alternative to standard 3He tubes and suitable for neutron detection systems in future spallation sources such as the European spallation source (ESS). Boron-based GEM (gas electron multiplier) detectors are a promising '3He-free' technology for thermal neutron detection in neutron scattering experiments. In this paper the evolution of boron-based GEM detectors from planar to 3D converters with an application in diffraction measurements is presented. The use of 3D converters coupled with GEMs allows for an optimization of the detector performances. Three different detectors were used for diffraction measurements on the INES instrument at the ISIS spallation source. The performances of the GEM-detectors are compared with those of conventional 3He tubes installed on the INES instrument. The conceptual detector with the 3D converter used in this paper reached a count rate per unit area of about 25% relative to the currently installed 3He tube. Its timing resolution is similar and the signal-to-background ratio (S/B) is 2 times lower.
  •  
8.
  •  
9.
  •  
10.
  • Biel, W., et al. (författare)
  • Diagnostics for plasma control - : From ITER to DEMO
  • 2019
  • Ingår i: Fusion engineering and design. - : ELSEVIER SCIENCE SA. - 0920-3796 .- 1873-7196. ; 146:A, s. 465-472
  • Tidskriftsartikel (refereegranskat)abstract
    • The plasma diagnostic and control (D&C) system for a future tokamak demonstration fusion reactor (DEMO) will have to provide reliable operation near technical and physics limits, while its front-end components will be subject to strong adverse effects within the nuclear and high temperature plasma environment. The ongoing developments for the ITER D&C system represent an important starting point for progressing towards DEMO. Requirements for detailed exploration of physics are however pushing the ITER diagnostic design towards using sophisticated methods and aiming for large spatial coverage and high signal intensities, so that many front-end components have to be mounted in forward positions. In many cases this results in a rapid aging of diagnostic components, so that additional measures like protection shutters, plasma based mirror cleaning or modular approaches for frequent maintenance and exchange are being developed. Under the even stronger fluences of plasma particles, neutron/gamma and radiation loads on DEMO, durable and reliable signals for plasma control can only be obtained by selecting diagnostic methods with regard to their robustness, and retracting vulnerable front-end components into protected locations. Based on this approach, an initial DEMO D&C concept is presented, which covers all major control issues by signals to be derived from at least two different diagnostic methods (risk mitigation).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 70

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy