SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tartoni N.) srt2:(2020-2023)"

Sökning: WFRF:(Tartoni N.) > (2020-2023)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Correa, J., et al. (författare)
  • The PERCIVAL detector : first user experiments
  • 2023
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 30, s. 242-250
  • Tidskriftsartikel (refereegranskat)abstract
    • The PERCIVAL detector is a CMOS imager designed for the soft X-ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ptychography at a free-electron laser, holographic imaging at a storage ring and preliminary tests on X-ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X-ray science.
  •  
2.
  • Pinaroli, G., et al. (författare)
  • PERCIVAL : Possible applications in X-ray micro-tomography
  • 2020
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 15:2
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray computed micro-tomography (μCT) is one of the most advanced and common non-destructive techniques in the field of medical imaging and material science. It allows recreating virtual models (3D models), without destroying the original objects, by measuring three-dimensional X-ray attenuation coefficient maps of samples on the (sub) micrometer scale. The quality of the images obtained using μCT is strongly dependent on the performance of the associated X-ray detector i.e. to the acquisition of information of the X-ray beam traversing the patient/sample being precise and accurate. Detectors for μCT have to meet the requirements of the specific tomography procedure in which they are going to be used. In general, the key parameters are high spatial resolution, high dynamic range, uniformity of response, high contrast sensitivity, fast acquisition readout and support of high frame rates. At present the detection devices in commercial μCT scanners are dominated by charge-coupled devices (CCD), photodiode arrays, CMOS acquisition circuits and more recently by hybrid pixel detectors. Monolithic CMOS imaging sensors, which offer reduced pixel sizes and low electronic noise, are certainly excellent candidates for μCT and may be used for the development of novel high-resolution imaging applications. The uses of monolithic CMOS based detectors such as the PERCIVAL detector are being recently explored for synchrotron and FEL applications. PERCIVAL was developed to operate in synchrotron and FEL facilities in the soft X-ray regime from 250 eV to 1 keV and it could offer all the aforementioned technical requirements needed in μCT experiments. In order to adapt the system for a typical tomography application, a scintillator is required, to convert incoming X-ray radiation (∼ tens of KeV) into visible light which may be detected with high efficiency. Such a taper-based scintillator was developed and mounted in front of the sensitive area of the PERCIVAL imager. In this presentation we will report the setup of the detector system and preliminary results of first μCTs of reference objects, which were performed in the TomoLab at ELETTRA. 
  •  
3.
  • Manzanillas, L., et al. (författare)
  • Development of multi-element monolithic germanium detectors for X-ray detection at synchrotron facilities
  • 2023
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1047
  • Tidskriftsartikel (refereegranskat)abstract
    • In past years efforts have concentrated on the development of arrays of Silicon Drift Detectors for X-ray spectroscopy. This is in stark contrast to the little effort that has been devoted to the improvement of germanium detectors, in particular for synchrotron applications. Germanium detectors have better energy resolution and are more efficient in detecting high energy photons than silicon detectors. In this context, the detector consortium of the European project LEAPS-INNOV has set an ambitious R&D program devoted to the development of a new generation of multi-element monolithic germanium detectors for X-ray detection. In order to improve the performance of the detector under development, simulations of the different detector design options have been performed. In this contribution, the efforts in terms of R&D are outlined with a focus on the modelization of the detector geometry and first performance results. These performance results show that a signal-to-background ratio larger than 1000 can be achieved in the energy range of interest from 5 keV to 100 keV.
  •  
4.
  • Orsini, F., et al. (författare)
  • XAFS-DET : A new high throughout X-ray spectroscopy detector system developed for synchrotron applications
  • 2023
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1045
  • Tidskriftsartikel (refereegranskat)abstract
    • The high brilliance and coherent beams resulting from recent upgraded synchrotron radiation facilities open the way for a large range of experiments, where detectors play a key role in the techniques and methods developed to fully exploit the upgraded synchrotron. For instance, one of the major limitations of XAFS experiment is the performance of the detectors. In order to be able to measure more challenging samples and to cope with the very high photon flux of the current and future (diffraction limited) sources, technological developments of detectors are necessary. In this framework, the germanium detector developed in the European project LEAPS-INNOV aims at improving several technological aspects. This type of detector represents a very important class of instruments for X-ray spectroscopy due to the fact that they enable to detect efficiently photons of considerable higher energy with respect to silicon detectors. The objective of this project consists in pushing the detector performance beyond the state-of-the-art. Preliminary layout and main choices for the design studies of this new detector are presented in this paper.
  •  