SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Teughels Wim)
 

Sökning: WFRF:(Teughels Wim) > (2013) > Soft and hard tissu...

Soft and hard tissue maintenance after the placement of immediate-loaded implants in the anterior maxilla : photographic and radiographic assessment

Pessoa, Roberto (författare)
Sousa, Ravel (författare)
Quirynen, Marc (författare)
visa fler...
Wenzel, Ann (författare)
Stavropoulos, Andreas (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Teughels, Wim (författare)
Spin-Neto, Rubens (författare)
visa färre...
 (creator_code:org_t)
2013-10-08
2013
Engelska.
Ingår i: Clinical Oral Implants Research. - : John Wiley & Sons. - 0905-7161 .- 1600-0501. ; 24:s9, s. 142-142
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Background: The dynamics of soft and hard tissue volume maintenance following the placement of immediate-loaded implants in aesthetic areas remains unclear in literature. Aim/Hypothesis: To present a method to evaluate by clinical (photography) and radiographic bi- and tri-dimensional means the alterations in soft and hard tissues following immediate implant placement and loading in the anterior maxilla. Material and methods: Ten patients, treated with immediateloaded implants in the maxillary central or lateral incisor, were evaluated in this study. Clinical parameters (distance from the tip of the crown to the interdental papilla – P; distance from the top of the crown to the gingiva – C; keratinized mucosa height – K) were evaluated in standardized pictures taken immediately after (baseline), and 1, 3, and 6 months after provisional implant-supported single crown placement. Bi-dimensional radiographic parameters (distance from the top of the implant to the first bone-to-implant contact – IT-FBIC; distance from the bone crest to the first bone-to-implant contact – BC-FBIC; lateral bone lost at the implant neck – LBL) were evaluated from standardized digital periapical radiographies acquired at the same time points, or from CBCT images (buccal bone wall thickness, measured at the top, the midpoint and the apex of the implant – TT, MT, and AT, respectively) acquired at baseline and 6 months after surgery. The volume of the buccal bone wall covering the central millimeter of the implant (BV) was also assessed in the CBCT images. Comparison among multiple periods of observation were performed using repeated-measures ANOVA followed by Tukey post-hoc test, while two-period based comparison were made using paired t-test. Results: The variation for all clinical (photographic), bi- and tri-dimensional parameters assessed was non-statistically significant. Mean P was 5.55 1 mm, considering all time periods, while C and K were 9.2 1.2 and 5.3 1.6 mm, respectively. Mean IT-FBIC was 1.3 0.8 mm, considering all time periods, whilst BC-FBIC and LBL were 3.9 1.1 and 0.3 0.1 mm, respectively. There was a 94% maintenance of BV. Conclusions and clinical implications: Assessed parameters showed good clinical, bi- and tri-dimensional radiographic stability of soft and hard tissues for implants immediately placed and loaded in aesthetic areas.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy