  • Johansen, Tone Bjordal, et al. (författare)
  • The 'Finnish new variant of Chlamydia trachomatis' escaping detection in the Aptima Combo 2 assay is widespread across Norway, June to August 2019
  • 2019
  • Ingår i: Eurosurveillance. - : European Centre for Disease Prevention and Control. - 1025-496X .- 1560-7917. ; 24:42, s. 2-6
  • Tidskriftsartikel (refereegranskat)abstract
    • The 'Finnish new variant of Chlamydia trachomatis' (FI-nvCT), escaping detection in the Aptima Combo 2 assay (AC2), is widespread across Norway. From June to August 2019, 84% (81/97) of available AC2/Aptima CT discordant samples from five laboratories were confirmed as FI-nvCT. Two additional CT variants (CT 23S rRNA C1514T and G1523A) also escaped AC2 detection. The high FI-nvCT proportion might indicate a long-term national spread and it cannot be excluded that FI-nvCT emerged in Norway.
  •  
2.
  •  
3.
  • Unemo, Magnus, 1970-, et al. (författare)
  • Sensitivity, specificity, inclusivity and exclusivity of the updated Aptima Combo 2 assay, which provides detection coverage of the new diagnostic-escape Chlamydia trachomatis variants
  • 2020
  • Ingår i: BMC Infectious Diseases. - : BioMed Central. - 1471-2334. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Four new variants of Chlamydia trachomatis (nvCTs), detected in several countries, cause false-negative or equivocal results using the Aptima Combo 2 assay (AC2; Hologic). We evaluated the clinical sensitivity and specificity, as well as the analytical inclusivity and exclusivity of the updated AC2 for the detection of CT and Neisseria gonorrhoeae (NG) on the automated Panther system (Hologic).Methods: We examined 1004 clinical AC2 samples and 225 analytical samples spiked with phenotypically and/or genetically diverse NG and CT strains, and other potentially cross-reacting microbial species. The clinical AC2 samples included CT wild type (WT)-positive (n = 488), all four described AC2 diagnostic-escape nvCTs (n = 170), NG-positive (n = 214), and CT/NG-negative (n = 202) specimens.Results: All nvCT-positive samples (100%) and 486 (99.6%) of the CT WT-positive samples were positive in the updated AC2. All NG-positive, CT/NG-negative, Trichomonas vaginalis (TV)-positive, bacterial vaginosis-positive, andCandida-positive AC2 specimens gave correct results. The clinical sensitivity and specificity of the updated AC2 for CT detection was 99.7 and 100%, respectively, and for NG detection was 100% for both. Examining spiked samples, the analytical inclusivity and exclusivity were 100%, i.e., in clinically relevant concentrations of spiked microbe.Conclusions: The updated AC2, including two CT targets and one NG target, showed a high sensitivity, specificity, inclusivity and exclusivity for the detection of CT WT, nvCTs, and NG. The updated AC2 on the fully automated Panther system offers a simple, rapid, high-throughput, sensitive, and specific diagnosis of CT and NG, which can easily be combined with detection of Mycoplasma genitalium and TV.
  •  