SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Twerenbold Raphael) srt2:(2017)"

Sökning: WFRF:(Twerenbold Raphael) > (2017)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lindahl, Bertil, et al. (författare)
  • An algorithm for rule-in and rule-out of acute myocardial infarction using a novel troponin I assay
  • 2017
  • Ingår i: Heart. - : BMJ. - 1355-6037 .- 1468-201X. ; 103:2, s. 125-131
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To derive and validate a hybrid algorithm for rule-out and rule-in of acute myocardial infarction based on measurements at presentation and after 2 hours with a novel cardiac troponin I (cTnI) assay. Methods The algorithm was derived and validated in two cohorts (605 and 592 patients) from multicentre studies enrolling chest pain patients presenting to the emergency department (ED) with onset of last episode within 12 hours. The index diagnosis and cardiovascular events up to 30 days were adjudicated by independent reviewers. Results In the validation cohort, 32.6% of the patients were ruled out on ED presentation, 6.1% were ruled in and 61.3% remained undetermined. A further 22% could be ruled out and 9.8% ruled in, after 2 hours. In total, 54.6% of the patients were ruled out with a negative predictive value (NPV) of 99.4% (95% CI 97.8% to 99.9%) and a sensitivity of 97.7% (95% CI 91.9% to 99.7%); 15.8% were ruled in with a positive predictive value (PPV) of 74.5% (95% CI 64.8% to 82.2%) and a specificity of 95.2% (95% CI 93.0% to 96.9%); and 29.6% remained undetermined after 2 hours. No patient in the rule-out group died during the 30-day follow-up in the two cohorts. Conclusions This novel two-step algorithm based on cTnI measurements enabled just over a third of the patients with acute chest pain to be ruled in or ruled out already at presentation and an additional third after 2 hours. This strategy maximises the speed of rule-out and rule-in while maintaining a high NPV and PPV, respectively.
  •  
2.
  • Pickering, John W., et al. (författare)
  • Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection A Collaborative Meta-analysis
  • 2017
  • Ingår i: Annals of Internal Medicine. - 0003-4819 .- 1539-3704. ; 166:10, s. 715-724
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: High-sensitivity assays for cardiac troponin T (hs-cTnT) are sometimes used to rapidly rule out acute myocardial infarction (AMI). Purpose: To estimate the ability of a single hs-cTnT concentration below the limit of detection (<0.005 mu g/L) and a nonischemic electrocardiogram (ECG) to rule out AMI in adults presenting to the emergency department (ED) with chest pain. Data Sources: EMBASE and MEDLINE without language restrictions (1 January 2008 to 14 December 2016). Study Selection: Cohort studies involving adults presenting to the ED with possible acute coronary syndrome in whom an ECG and hs-cTnT measurements were obtained and AMI outcomes adjudicated during initial hospitalization. Data Extraction: Investigators of studies provided data on the number of low-risk patients (no new ischemia on ECG and hs-cTnT measurements <0.005 mu g/L) and the number who had AMI during hospitalization (primary outcome) or a major adverse cardiac event (MACE) or death within 30 days (secondary outcomes), by risk classification (low or not low risk). Two independent epidemiologists rated risk of bias of studies. Data Synthesis: Of 9241 patients in 11 cohort studies, 2825 (30.6%) were classified as low risk. Fourteen (0.5%) low-risk patients had AMI. Sensitivity of the risk classification for AMI ranged from 87.5% to 100% in individual studies. Pooled estimated sensitivity was 98.7% (95% CI, 96.6% to 99.5%). Sensitivity for 30-day MACEs ranged from 87.9% to 100%; pooled sensitivity was 98.0% (CI, 94.7% to 99.3%). No low-risk patients died. Limitation: Few studies, variation in timing and methods of reference standard troponin tests, and heterogeneity of risk and prevalence of AMI across studies. Conclusion: A single hs-cTnT concentration below the limit of detection in combination with a nonischemic ECG may successfully rule out AMI in patients presenting to EDs with possible emergency acute coronary syndrome.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy