Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?

Manouras, Aristomenis (författare)
Karolinska Institutet,KTH,Medicinsk teknik
Shala, Arben (författare)
Nyktari, Evangelia (författare)
visa fler...
Shahgaldi, Kambiz (författare)
Winter, Reidar (författare)
Karolinska Institutet
Vardas, Panagiotis (författare)
Brodin, Lars-Åke (författare)
Karolinska Institutet,KTH,Medicinsk teknik
Nowak, Jacek (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2009-06-23
2009
Engelska.
Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 7, s. 29-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated. Methods: Left ventricular (LV) longitudinal systolic myocardial velocities and displacement during ejection period were quantified at the basal septal and lateral wall in 24 healthy individuals (4 women and 20 men, 34 +/- 12 years) using spectral TD, colour TD and M-mode recordings. Mean, maximal and minimal spectral TD systolic velocities and the corresponding displacement values were obtained by measurements at the outer and inner borders of the spectral velocity signal. The results were then compared with those obtained with the two other modalities used. Results: Systolic myocardial velocities derived from mean spectral TD frequencies were highly concordant with corresponding colour TD measurements (mean difference 0.10 +/- 0.54 cm/sec in septal and 0.09 +/- 0.97 cm/sec in lateral wall). Similarly, the agreement between spectral and colour TD (mean difference 0.22 +/- 0.74 mm in septal and 0.02 +/- 0.86 mm in lateral wall) as well as M-mode was good when mean spectral velocities were temporally integrated and the results did not differ statistically. Conversely, displacement values from the inner or outer border of the spectral signal differed significantly from values obtained with colour TD and M-mode (p < 0.001, in both cases). Conclusion: LV systolic myocardial measurements based on mean spectral TD frequencies are highly concordant with those provided by colour TD and M-mode. Hence, in order to maintain compatibility of the results, the use of this particular spectral TD procedure should be advocated in clinical praxis.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

LEFT-VENTRICULAR FUNCTION
M-MODE ECHOCARDIOGRAPHY
WALL-MOTION
IN-VIVO
ABNORMALITIES
FLOW
TIME
Medical engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy