SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vaughan S.) srt2:(2000-2004)"

Sökning: WFRF:(Vaughan S.) > (2000-2004)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Duggan, P, et al. (författare)
  • Gamma-ray bursts and X-ray melting of material to form chondrules and planets
  • 2003
  • Ingår i: Astronomy & Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 409:2, s. 9-12
  • Tidskriftsartikel (refereegranskat)abstract
    • Chondrules are millimeter sized objects of spherical to irregular shape that constitute the major component of chondritic meteorites that originate in the region between Mars and Jupiter and which fall to Earth. They appear to have solidified rapidly from molten or partially molten drops. The heat source that melted the chondrules remains uncertain. The intense radiation from a gamma-ray burst (GRB) is capable of melting material at distances up to 300 light years. These conditions were created in the laboratory for the first time when millimeter sized pellets were placed in a vacuum chamber in the white synchrotron beam at the European Synchrotron Radiation Facility (ESRF). The pellets were rapidly heated in the X-ray and gamma-ray furnace to above 1400 degreesC melted and cooled. This process heats from the inside unlike normal furnaces. The melted spherical samples were examined with a range of techniques and found to have microstructural properties similar to the chondrules that come from meteorites. This experiment demonstrates that GRBs can melt precursor material to form chondrules that may subsequently influence the formation of planets. This work extends the field of laboratory astrophysics to include high power synchrotron sources.
  •  
4.
  • Macefield, Vaughan G, et al. (författare)
  • Loads applied tangential to a fingertip during an object restraint task can trigger short-latency as well as long-latency EMG responses in hand muscles.
  • 2003
  • Ingår i: Experimental Brain Research. - : Springer Science and Business Media LLC. - 0014-4819 .- 1432-1106. ; 152:2, s. 143-149
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrical stimulation of the digital nerves can cause short- and long-latency increases in electromyographic activity (EMG) of the hand muscles, but mechanical stimulation of primarily tactile afferents in the digits generally evokes only a long-latency increase in EMG. To examine whether such stimuli can elicit short-latency reflex responses, we recorded EMG over the first dorsal interosseous muscle when subjects (n=13) used the tip of the right index finger to restrain a horizontally oriented plate from moving when very brisk tangential forces were applied in the distal direction. The plate was subjected to ramp-and-hold pulling loads at two intensities (a 1-N load applied at 32 N/s or a 2-N load applied at 64 N/s) at times unpredictable to the subjects (mean interval 2 s; trial duration 500 ms). The contact surface of the manipulandum was covered with rayon--a slippery material. For each load, EMG was averaged for 128 consecutive trials with reference to the ramp onset. In all subjects, an automatic increase in grip force was triggered by the loads applied at 32 N/s; the mean onset latency of the EMG response was 59.8 +/- 0.9 (mean +/- SE) ms. In seven subjects (54%) this long-latency response was preceded by a weak short-latency excitation at 34.6 +/- 2.9 ms. With the loads applied at 64 N/s, the long-latency response occurred slightly earlier (58.9 +/- 1.7 ms) and, with one exception, all subjects generated a short-latency EMG response (34.9 +/- 1.3 ms). Despite the higher background grip force that subjects adopted during the stronger loads (4.9 +/- 0.3 N vs 2.5 +/- 0.2 N), the incidence of slips was higher--the manipulandum escaped from the grasp in 37 +/- 5% of trials with the 64 N/s ramps, but in only 18 +/- 4% with the 32-N/s ramps. The deformation of the fingertip caused by the tangential load, rather than incipient or overt slips, triggered the short-latency responses because such responses occurred even when the finger pad was fixed to the manipulandum with double-sided adhesive tape so that no slips occurred.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy