SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vejbrink Kildal Villiam) srt2:(2024)"

Sökning: WFRF:(Vejbrink Kildal Villiam) > (2024)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Vejbrink Kildal, Villiam, et al. (författare)
  • Preoperative assessment of depressor anguli oris to prevent myectomy failure : An anatomical study using high-resolution ultrasound
  • 2024
  • Ingår i: Journal of Plastic, Reconstructive & Aesthetic Surgery. - : Elsevier. - 1748-6815 .- 1878-0539. ; 88, s. 296-302
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Myectomies of the lower lip depressor muscles have unexplained high failure rates. This study aimed to examine the depressor anguli oris (DAO) muscle using high-resolution ultrasound to identify potential anatomical explanations for surgical failures and to determine the accuracy of utilizing preoperative ultrasound assessment to improve myectomies.Methods: Anatomical features of DAO and the surrounding anatomy were examined in 38 hemifaces of human body donors using high-resolution ultrasound and dissection.Results: The ultrasound and dissection measurements showed the DAO muscle width to be 16.2 ± 2.9 versus 14.5 ± 2.5 mm, respectively, and the location of the lateral muscle border 54.4 ± 5.7 versus 52.3 ± 5.4 mm lateral to the midline. In 60% of the cases, the facial artery was either completely covered by lateral DAO muscle fibers or was found to be in direct contact with the lateral border. Significant muscle fiber continuity was present between the DAO and surrounding muscles in 5% of cases, whereas continuity between the depressor labii inferioris and surrounding muscles was considerably more common and pronounced.Conclusions: High-resolution ultrasound can accurately reveal important preoperative anatomical information in myectomies. Two potential explanations for the surgical failures were discovered: an overlap of lateral DAO muscle fibers over the facial artery could lead to inadequate resections and continuity with the surrounding muscles might lead to muscle function takeover despite adequate resections. Both can be uncovered preoperatively by the surgeon through a brief, directed ultrasound examination, which may allow for modification of the surgical plan to reduce surgical failure.
  •  
2.
  • Vejbrink Kildal, Villiam, M.D., et al. (författare)
  • Ultrasound-guided injections for treatment of facial paralysis sequelae : A randomized study on body donors
  • 2024
  • Ingår i: Plastic and reconstructive surgery (1963). - : Wolters Kluwer. - 0032-1052 .- 1529-4242. ; 153:3, s. 617e-625e
  • Tidskriftsartikel (refereegranskat)abstract
    • Background:  Botulinum toxin injection is the gold standard treatment of synkinesis and gustatory hyperlacrimation in facial paralysis patients. However, poor injection accuracy may lead to suboptimal treatment results and complications. Diplopia, ptosis, and lagophthalmos are common after lacrimal gland injections. Intra-ocular injections have been reported in the treatment of both synkinesis and excessive tearing. Ultrasound guidance should increase injection accuracy in the facial region, but this has not been proven.Methods:  Twenty-six hemifaces of non-embalmed cadavers were studied in a randomized split-face manner. Ink was injected with ultrasound or landmark guidance into the lacrimal gland and three common synkinetic muscles: the orbicularis oculi, depressor anguli oris, and mentalis. Injection accuracy was evaluated through several measures.Results:  Using ultrasound guidance, most ink (>50%) was found inside the correct target in 88% of cases, compared with 50% using landmark guidance (p<0.001). This was most pronounced in the lacrimal gland (62% vs. 8%), depressor anguli oris (100% vs. 46%), and mentalis (100% vs. 54%) (p<0.05). All ink was found inside the correct target (no ink outside) in 65% using ultrasound guidance vs. 29% without (p<0.001). Injection accuracy (any ink in target) was 100% when using ultrasound guidance vs. 83% without (p<0.01). Twenty-three percent of landmark-guided depressor anguli oris injections stained the facial artery (p=0.22).Conclusions:  Ultrasound guidance significantly increased injection accuracy and reduced the amount of ink lost in surrounding tissue when compared with landmark guidance. Clinical trials are needed to explore the effects of ultrasound guidance on treatment outcome, duration, and complications in facial paralysis patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy