SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Weninger Clemens) srt2:(2020-2023)"

Sökning: WFRF:(Weninger Clemens) > (2020-2023)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Berkowicz, Sharon, et al. (författare)
  • Nanofocused x-ray photon correlation spectroscopy
  • 2022
  • Ingår i: Physical Review Research. - 2643-1564. ; 4:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Here, we demonstrate an experimental proof of concept for nanofocused x-ray photon correlation spectroscopy, a technique sensitive to nanoscale fluctuations present in a broad range of systems. The experiment, performed at the NanoMAX beamline at MAX IV, uses a novel event-based x-ray detector to capture nanoparticle structural dynamics with microsecond resolution. By varying the nanobeam size from σ=88 nm to σ=2.5μm, we quantify the effect of the nanofocus on the small-angle scattering lineshape and on the diffusion coefficients obtained from nano-XPCS. We observe that the use of nanobeams leads to a multifold increase in speckle contrast, which greatly improves the experimental signal-to-noise ratio, quantified from the two-time intensity correlation functions. We conclude that it is possible to account for influence of the high beam divergence on the lineshape and measured dynamics by including a convolution with the nanobeam profile in the model.
  •  
2.
  • Björling, Alexander, et al. (författare)
  • Contrast - a lightweight Python framework for beamline orchestration and data acquisition
  • 2021
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 28:4, s. 1253-1260
  • Tidskriftsartikel (refereegranskat)abstract
    • The emergence of fourth-generation synchrotrons is prompting the development of new systems for experimental control and data acquisition. However, as general control systems are designed to cover a wide set of instruments and techniques, they tend to become large and complicated, at the cost of experimental flexibility. Here we present Contrast, a simple Python framework for interacting with beamline components, orchestrating experiments and managing data acquisition. The system is presented and demonstrated via its application at the NanoMAX beamline of the MAX IV Laboratory.
  •  
3.
  • Bogacz, Isabel, et al. (författare)
  • Room temperature X-ray absorption spectroscopy of metalloenzymes with drop-on-demand sample delivery at XFELs
  • 2023
  • Ingår i: Pure and Applied Chemistry. - 0033-4545. ; 95:8, s. 891-897
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray crystallography and X-ray spectroscopy using X-ray free electron lasers plays an important role in understanding the interplay of structural changes in the protein and the chemical changes at the metal active site of metalloenzymes through their catalytic cycles. As a part of such an effort, we report here our recent development of methods for X-ray absorption spectroscopy (XAS) at XFELs to study dilute biological samples, available in limited volumes. Our prime target is Photosystem II (PS II), a multi subunit membrane protein complex, that catalyzes the light-driven water oxidation reaction at the Mn4CaO5 cluster. This is an ideal system to investigate how to control multi-electron/proton chemistry, using the flexibility of metal redox states, in coordination with the protein and the water network. We describe the method that we have developed to collect XAS data using PS II samples with a Mn concentration of <1 mM, using a drop-on-demand sample delivery method.
  •  
4.
  • Carbone, Dina, et al. (författare)
  • Design and performance of a dedicated coherent X-ray scanning diffraction instrument at beamline NanoMAX of MAX IV
  • 2022
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 29, s. 876-887
  • Tidskriftsartikel (refereegranskat)abstract
    • The diffraction endstation of the NanoMAX beamline is designed to provide high-flux coherent X-ray nano-beams for experiments requiring many degrees of freedom for sample and detector. The endstation is equipped with high-efficiency Kirkpatrick-Baez mirror focusing optics and a two-circle goniometer supporting a positioning and scanning device, designed to carry a compact sample environment. A robot is used as a detector arm. The endstation, in continued development, has been in user operation since summer 2017.
  •  
5.
  •  
6.
  • Fransson, Thomas, et al. (författare)
  • Effects of x-ray free-electron laser pulse intensity on the Mn K beta(1,3) x-ray emission spectrum in photosystem II-A case study for metalloprotein crystals and solutions
  • 2021
  • Ingår i: Structural Dynamics. - : AIP Publishing. - 2329-7778. ; 8:6
  • Tidskriftsartikel (refereegranskat)abstract
    • In the last ten years, x-ray free-electron lasers (XFELs) have been successfully employed to characterize metalloproteins at room temperature using various techniques including x-ray diffraction, scattering, and spectroscopy. The approach has been to outrun the radiation damage by using femtosecond (fs) x-ray pulses. An example of an important and damage sensitive active metal center is the Mn4CaO5 cluster in photosystem II (PS II), the catalytic site of photosynthetic water oxidation. The combination of serial femtosecond x-ray crystallography and K beta x-ray emission spectroscopy (XES) has proven to be a powerful multimodal approach for simultaneously probing the overall protein structure and the electronic state of the Mn4CaO5 cluster throughout the catalytic (Kok) cycle. As the observed spectral changes in the Mn4CaO5 cluster are very subtle, it is critical to consider the potential effects of the intense XFEL pulses on the K beta XES signal. We report here a systematic study of the effects of XFEL peak power, beam focus, and dose on the Mn K beta(1,3) XES spectra in PS II over a wide range of pulse parameters collected over seven different experimental runs using both microcrystal and solution PS II samples. Our findings show that for beam intensities ranging from & SIM;5 x 10(15) to 5 x 10(17) W/cm(2) at a pulse length of & SIM;35 fs, the spectral effects are small compared to those observed between S-states in the Kok cycle. Our results provide a benchmark for other XFEL-based XES studies on metalloproteins, confirming the viability of this approach.& nbsp;
  •  
7.
  • Fransson, Thomas, et al. (författare)
  • Effects of x-ray free-electron laser pulse intensity on the Mn K β 1,3x-ray emission spectrum in photosystem II - A case study for metalloprotein crystals and solutions
  • 2021
  • Ingår i: Structural Dynamics. - : American Institute of Physics (AIP). - 2329-7778. ; 8:6
  • Tidskriftsartikel (refereegranskat)abstract
    • In the last ten years, x-ray free-electron lasers (XFELs) have been successfully employed to characterize metalloproteins at room temperature using various techniques including x-ray diffraction, scattering, and spectroscopy. The approach has been to outrun the radiation damage by using femtosecond (fs) x-ray pulses. An example of an important and damage sensitive active metal center is the Mn4CaO5 cluster in photosystem II (PS II), the catalytic site of photosynthetic water oxidation. The combination of serial femtosecond x-ray crystallography and Kβ x-ray emission spectroscopy (XES) has proven to be a powerful multimodal approach for simultaneously probing the overall protein structure and the electronic state of the Mn4CaO5 cluster throughout the catalytic (Kok) cycle. As the observed spectral changes in the Mn4CaO5 cluster are very subtle, it is critical to consider the potential effects of the intense XFEL pulses on the Kβ XES signal. We report here a systematic study of the effects of XFEL peak power, beam focus, and dose on the Mn Kβ1,3 XES spectra in PS II over a wide range of pulse parameters collected over seven different experimental runs using both microcrystal and solution PS II samples. Our findings show that for beam intensities ranging from ∼5 × 1015 to 5 × 1017 W/cm2 at a pulse length of ∼35 fs, the spectral effects are small compared to those observed between S-states in the Kok cycle. Our results provide a benchmark for other XFEL-based XES studies on metalloproteins, confirming the viability of this approach.
  •  
8.
  • Jensen, Alexander Bernthz, et al. (författare)
  • Very large-scale diffraction investigations enabled by a matrix-multiplication facilitated radial and azimuthal integration algorithm : MatFRAIA
  • 2022
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 29, s. 1420-1428
  • Tidskriftsartikel (refereegranskat)abstract
    • As synchrotron facilities continue to generate increasingly brilliant X-rays and detector speeds increase, swift data reduction from the collected area detector images to more workable 1D diffractograms becomes of increasing importance. This work reports an integration algorithm that can integrate diffractograms in real time on modern laptops and can reach 10 kHz integration speeds on modern workstations using an efficient pixel-splitting and parallelization scheme. This algorithm is limited not by the computation of the integration itself but is rather bottlenecked by the speed of the data transfer to the processor, the data decompression and/or the saving of results. The algorithm and its implementation is described while the performance is investigated on 2D scanning X-ray diffraction/fluorescence data collected at the interface between an implant and forming bone.
  •  
9.
  • Johansson, Ulf, et al. (författare)
  • NanoMAX : the hard X-ray nanoprobe beamline at the MAX IV Laboratory
  • 2021
  • Ingår i: Journal of Synchrotron Radiation. - : International Union of Crystallography (IUCr). - 0909-0495 .- 1600-5775. ; 28, s. 1935-1947
  • Tidskriftsartikel (refereegranskat)abstract
    • NanoMAX is the first hard X-ray nanoprobe beamline at the MAX IV laboratory. It utilizes the unique properties of the world's first operational multi-bend achromat storage ring to provide an intense and coherent focused beam for experiments with several methods. In this paper we present the beamline optics design in detail, show the performance figures, and give an overview of the surrounding infrastructure and the operational diffraction endstation.
  •  
10.
  • Kahnt, Maik, et al. (författare)
  • Measurement of the coherent beam properties at the CoSAXS beamline
  • 2021
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495. ; 28, s. 1948-1953
  • Tidskriftsartikel (refereegranskat)abstract
    • The CoSAXS beamline at the MAX IV Laboratory is a modern multi-purpose (coherent) small-Angle X-ray scattering (CoSAXS) instrument, designed to provide intense and optionally coherent illumination at the sample position, enabling coherent imaging and speckle contrast techniques. X-ray tracing simulations used to design the beamline optics have predicted a total photon flux of 1012-1013 photons s-1 and a degree of coherence of up to 10% at 7.1 keV. The normalized degree of coherence and the coherent flux of this instrument were experimentally determined using the separability of a ptychographic reconstruction into multiple mutually incoherent modes and thus the Coherence in the name CoSAXS was verified. How the beamline can be used both for coherent imaging and XPCS measurements, which both heavily rely on the degree of coherence of the beam, was demonstrated. These results are the first experimental quantification of coherence properties in a SAXS instrument at a fourth-generation synchrotron light source.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy