SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wennerberg Ann 1955) srt2:(2020-2023)"

Sökning: WFRF:(Wennerberg Ann 1955) > (2020-2023)

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kassapidou, Maria, et al. (författare)
  • Cobalt-chromium alloys fabricated with four different techniques: Ion release, toxicity of released elements and surface roughness
  • 2020
  • Ingår i: Dental Materials. - : Elsevier BV. - 0109-5641 .- 1879-0097. ; 36:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To investigate the metal ion release, surface roughness and cytoxicity for Co-Cr alloys produced by different manufacturing techniques before and after heat treatment. In addition, to evaluate if the combination of materials affects the ion release. Methods. Five Co-Cr alloys were included, based on four manufacturing techniques. Commercially pure titanium, CpTi grade 4 and a titanium alloy were included for comparison. The ion release tests involved both Inductive Coupled Plasma Optical Emission Spectrometry and Inductive Coupled Plasma Mass Spectrometry analyses. The surface analysis was conducted with optical interferometry. Cells were indirectly exposed to the materials and cell viability was evaluated with the MTT (3-(4.5-dimethylthiazol-2-yl)-2.5-diphenyltetrazolium bromide) method. Results. All alloys showed a decrease of the total ion release when CpTi grade 4 was present. The total ion release decreased over time for all specimens and the highest ion release was observed from the cast and milled Co-Cr alloy in acidic conditions. The cast and laser-melted Co-Cr alloy and the titanium alloy became rougher after heat treatment. All materials were within the limits of cell viability according to standards. Significance. The ion release from Co-Cr alloys is influenced by the combination of materials, pH and time. Surface roughness is influenced by heat treatment. Furthermore, both ion release and surface roughness are influenced by the manufacturing technique and the alloy type. The clinical implication needs to be further investigated. (C) 2020 The Academy of Dental Materials. Published by Elsevier Inc.
  •  
2.
  • Albrektsson, Tomas, 1945, et al. (författare)
  • An Imbalance of the Immune System Instead of a Disease Behind Marginal Bone Loss Around Oral Implants: Position Paper
  • 2020
  • Ingår i: The International journal of oral & maxillofacial implants. - : Quintessence Publishing. - 1942-4434 .- 0882-2786. ; 35:3, s. 495-502
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The purpose of this paper is to present evidence that supports the notion that the primary reason behind marginal bone loss and implant failure is immune-based and that bacterial actions in the great majority of problematic cases are of a secondary nature. MATERIALS AND METHODS: The paper is written as a narrative review. RESULTS: Evidence is presented that commercially pure titanium is not biologically inert, but instead activates the innate immune system of the body. For its function, the clinical implant is dependent on an immune/inflammatory defense against bacteria. Biologic models such as ligature studies have incorrectly assumed that the primary response causing marginal bone loss is due to bacterial action. In reality, bacterial actions are secondary to an imbalance of the innate immune system caused by the combination of titanium implants and ligatures, ie, nonself. This immunologic imbalance may lead to marginal bone resorption even in the absence of bacteria. CONCLUSION: Marginal bone loss and imminent oral implant failure cannot be properly analyzed without a clear understanding of immunologically caused tissue responses.
  •  
3.
  • Bruns, S., et al. (författare)
  • On the material dependency of peri-implant morphology and stability in healing bone
  • 2023
  • Ingår i: Bioactive Materials. - : Elsevier. - 2452-199X. ; 28, s. 155-166
  • Tidskriftsartikel (refereegranskat)abstract
    • The microstructural architecture of remodeled bone in the peri-implant region of screw implants plays a vital role in the distribution of strain energy and implant stability. We present a study in which screw implants made from titanium, polyetheretherketone and biodegradable magnesium-gadolinium alloys were implanted into rat tibia and subjected to a push-out test four, eight and twelve weeks after implantation. Screws were 4 mm in length and with an M2 thread. The loading experiment was accompanied by simultaneous three-dimensional imaging using synchrotron-radiation microcomputed tomography at 5 mu m resolution. Bone deformation and strains were tracked by applying optical flow-based digital volume correlation to the recorded image sequences. Implant stabilities measured for screws of biodegradable alloys were comparable to pins whereas non-degradable biomaterials experienced additional mechanical stabilization. Peri-implant bone morphology and strain transfer from the loaded implant site depended heavily on the biomaterial utilized. Titanium implants stimulated rapid callus formation displaying a consistent monomodal strain profile whereas the bone volume fraction in the vicinity of magnesium-gadolinium alloys exhibited a minimum close to the interface of the implant and less ordered strain transfer. Correlations in our data suggest that implant stability benefits from disparate bone morphological properties depending on the biomaterial utilized. This leaves the choice of biomaterial as situational depending on local tissue properties.
  •  
4.
  • Duddeck, D. U., et al. (författare)
  • Quality Assessment of Five Randomly Chosen Ceramic Oral Implant Systems: Cleanliness, Surface Topography, and Clinical Documentation
  • 2021
  • Ingår i: International Journal of Oral & Maxillofacial Implants. - : Quintessence Publishing. - 0882-2786 .- 1942-4434. ; 36:5, s. 863-874
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: After some initial setbacks in the 1970s, ceramic implants seem to be a promising alternative to titanium implants. Since the surface of an implant system represents the interface to surrounding biologic structures, the study focuses on cleanliness and surface topography. Clinical documentation of the corresponding systems completes the picture and allows a better evaluation of zirconia implant systems. Materials and Methods: Five different ceramic implant systems were selected randomly and purchased via blind-shopping: Z5s (Z-Systems), ZiBone (COHO), W implant (TAVDental), ceramic. implant (vitaclinical), and BioWinI/Standard Zirkon Implantat (Champions-Implants/ZV3 system). Three samples of each implant system underwent scanning electron microscopy (SEM) imaging and elemental analysis (EDS). Where appropriate, subsequent Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) was performed to identify the chemical nature of impurities. Surface topography was evaluated, and a search for clinical trials in the PubMed database, on the websites and by written request to each dental implant manufacturer, was performed. Results: Surfaces of Champions implants (ZV3) and Z-Systems implants were relatively clean, whereas the other investigated surfaces of vitaclinical, TAV Dental, and ZiBone implants all displayed organic contaminations on their surfaces. Four of the investigated ceramic implants showed a moderately rough implant surface. Only the vitaclinical ceramic implant had minimal surface roughness. Three ceramic designs-vitaclinical, ZV3, and Z-Systems-had clinical trials documented with up to 3 years of follow-up and results varying between 82.5% and 100% survival. TAV Dental W and ZiBone implant systems lacked properly conducted clinical recording of results. Conclusion: The results of this study showed that it is technically possible to produce zirconia implants that are largely residue-free. On the other hand, the variety of significant residues found in this analysis raises concerns, as contamination may lead to undesirable biologic effects. The lack of clinical studies in peer-reviewed journals does not seem to be relevant for the approval of marketing, nor does the lack of surface cleanliness. In the authors' opinion, a critical analysis of these aspects should be included in a more stringent future analysis prior to the marketing of oral implant systems.
  •  
5.
  • Fahlstedt, P., et al. (författare)
  • Dental implant surface morphology, chemical composition, and topography following double wavelength (2780/940 nm) laser irradiation. An in vitro study
  • 2023
  • Ingår i: Clinical and Experimental Dental Research. - : Wiley. - 2057-4347. ; 9:1, s. 25-35
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The aim of this in vitro study was to evaluate morphology alterations, chemical composition, and topography of moderately rough dental implants following double-wavelength laser irradiation. Material and Methods: Commercial-grade titanium dental implants representing different surface characteristics (Osseospeed [OS], TiUnite [TiU], and Roxolid SLActive [RS]) were used. Laser irradiation was performed using a computer-controlled robotic device with calibrated energy/power settings and deionized water spray. Micro-, nano-morphology surface alterations, chemical composition, and surface topography (Sa, Sds, Sdr) in the test group (laser plus water), control group A (water only), and control group B (no treatment) were analyzed using scanning electron microscopy (SEM), energy-dispersive X-ray analysis (EDX), and white light laser profilometer (Interferometry). Results: SEM-evaluation revealed minor between-group differences in micro- and nano-morphology within each implant system. Significant overall differences in surface element content were observed between the test and control group B for all implant systems (p <.05). For the test compared with control group B, statistically significantly higher oxygen content was detected for OS and RS (p <.05), a corresponding significant difference was detected for carbon for TiU (p <.05). For RS, a significantly lower content of titanium and zirconium was detected within the test group (p <.05). A significant difference in topography between test and control group B was observed for OS (Sa: p =.039 and Sdr: p =.041) with the highest roughness value for control group B. Conclusions: Altered chemical composition and surface topography were observed for all implant surfaces compared with untreated control following double wavelength laser irradiation. A clinical evaluation of the impact of the altered surface composition following double wavelength laser irradiation on the ability to reosseointegrate appears warranted.
  •  
6.
  • Gjelvold, Björn, et al. (författare)
  • Immediate Loading of Single Implants, Guided Surgery, and Intraoral Scanning: A Nonrandomized Study
  • 2020
  • Ingår i: International Journal of Prosthodontics. - : Quintessence Publishing. - 0893-2174 .- 1139-9791. ; 33:5, s. 513-522
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare clinical and esthetic outcomes between immediately loaded single implants placed with and without a fully guided surgical procedure. Materials and Methods: Patients with a missing maxillary tooth (second premolar to second premolar) were considered for inclusion in this 1-year prospective nonrandomized study. Exclusion criteria were general health contraindications for oral surgery besides the need for bone grafting or ridge augmentation. One group received digital implant planning, fully guided surgery, and immediate loading (DIL). The other group received freehand surgery and immediate loading (IL). Outcome measures were implant survival, marginal bone loss, soft tissue changes, papilla index, pink and white esthetic scores (PES and WES, respectively), and patient-reported outcome measures (PROMs). Results: Two of 21 implants failed in the DIL group soon after placement, resulting in a 1-year implant survival rate of 90.5%, while no implants failed in the IL group. Significantly higher papilla index scores and lower soft tissue changes were found for the DIL group compared to the IL group. No differences were found after 1 year regarding marginal bone loss, PES, WES, or PROMs. Conclusion: Within the limitations of this study, immediate loading in combination with fully guided surgery might negatively affect implant survival. Immediate loading, fully guided surgery, and a digital workflow appear to have a positive effect on early soft tissue adaptation.
  •  
7.
  • Kjellin, P., et al. (författare)
  • A nanosized zirconium phosphate coating for PEEK implants and its effect in vivo
  • 2020
  • Ingår i: Materialia. - : Elsevier BV. - 2589-1529. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • Surface treatments and coatings can be applied to polyether ether ketone (PEEK) implants to improve their ability to osseointegrate. A new coating, consisting of amorphous nanosized zirconium phosphate (ZrP) was applied to PEEK and titanium substrates. The coating was applied by using a microemulsion as a carrier for the nanoparticles. It was found that the coating formed a thin continuous porous layer on top of the substrate, with pore diameters of 10–50 nm. The thickness of the coating was estimated to <100 nm. The resistance to acidic (pH = 4) conditions and exposure to ultrasonication was investigated with XPS, which showed no loss of coating. The adherence of the coating was investigated by insertion of implants in simulated bone material, which showed a minor loss in coating. In vitro (SBF) testing showed that the coating promoted crystallization of calcium phosphates, for uncoated PEEK, no crystallization was detected. The in vivo performance of the ZrP coating was examined by coating screw shaped PEEK implants which were implanted in rabbit tibia for 6 weeks. The anchoring strength of the implants was evaluated with removal torque (RTQ) measurements. The average RTQ for the ZrP coated implants was significantly higher compared to the non-coated implants. The results show that a nanosized ZrP coating on PEEK implants can transform the surface from having a low ability to osseointegrate to a surface which stimulates bone tissue growth. This makes the ZrP coating an interesting alternative for coating PEEK implants, such as spinal fusion cages and tendon fixation screws. © 2020
  •  
8.
  • Kruger, D., et al. (författare)
  • High-resolution ex vivo analysis of the degradation and osseointegration of Mg-xGd implant screws in 3D
  • 2022
  • Ingår i: Bioactive Materials. - : Elsevier BV. - 2452-199X. ; 13, s. 37-52
  • Tidskriftsartikel (refereegranskat)abstract
    • Biodegradable magnesium (Mg) alloys can revolutionize osteosynthesis, because they have mechanical properties similar to those of the bone, and degrade over time, avoiding the need of removal surgery. However, they are not yet routinely applied because their degradation behavior is not fully understood. In this study we have investigated and quantified the degradation and osseointegration behavior of two biodegradable Mg alloys based on gadolinium (Gd) at high resolution. Mg-5Gd and Mg-10Gd screws were inserted in rat tibia for 4, 8 and 12 weeks. Afterward, the degradation rate and degradation homogeneity, as well as bone-to-implant interface, were studied with synchrotron radiation micro computed tomography and histology. Titanium (Ti) and polyether ether ketone (PEEK) were used as controls material to evaluate osseointegration. Our results showed that Mg-5Gd degraded faster and less homogeneously than Mg-10Gd. Both alloys gradually form a stable degradation layer at the interface and were surrounded by new bone tissue. The results were correlated to in vitro data obtained from the same material and shape. The average bone-to-implant contact of the Mg-xGd implants was comparable to that of Ti and higher than for PEEK. The results suggest that both Mg-xGd alloys are suitable as materials for bone implants.
  •  
9.
  • Olander, Julia, 1984, et al. (författare)
  • Implant-Supported Single Crowns with Titanium or Zirconia Abutments: A Retrospective Up-to-5-year Follow-up Study.
  • 2022
  • Ingår i: The International journal of prosthodontics. - : Quintessence Publishing. - 1942-4426 .- 0893-2174. ; 35:4, s. 387-395
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare the clinical outcomes of single implants with titanium (Ti) or zirconia (Zr) abutments after up to 5 years in function.This study was a retrospective analysis on single implants with screw-retained abutments (Zr or Ti) covered with porcelain veneer placed between 2011 and 2013 at one referral specialist clinic. Clinical data from patient records were collected from 132 patients and 174 implants. Technical complications such as fractures, chipping, and abutment screw loosening were registered. Radiographs were analyzed comparing both annual bone loss and accumulated bone loss at 5 years. In 57 patients with 85 implants, the values of accumulated bone loss at 5 years were compared to baseline.Technical complications occurred in 16 (9%) of the implants, most often during the first year. The following complications were found: fracture of the abutment (n = 1); loosening of the abutment screws (n = 5); and chipping of the porcelain veneer (n = 11). Ti abutments had more complications than Zr abutments (79%). Of all the implants, 45% had an annual bone loss ranging between 0.05 and 2.15 mm, and 59% had an accumulated bone loss at 5 years ranging between 0.05 and 4.25 mm. Zr abutments had a statistically significantly higher amount of yearly and accumulated bone loss at 5 years.Abutment material affected marginal bone loss. The Zr group displayed statistically more bone loss both yearly and after 5 years compared to the Ti group. Technical complications were not affected by abutment material but were affected by age of the patient.
  •  
10.
  • Olander, Julia, 1984, et al. (författare)
  • Inflammatory Gene Profile and Particle Presence in Peri-Implant Mucosa: a Pilot Study on 9 Patients
  • 2023
  • Ingår i: Jomr-Journal of Oral & Maxillofacial Research. - 2029-283X. ; 14:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The purpose of this pilot study is to compare gene expression in mucosa around dental implants with zirconia abutment to titanium and investigate presence of particles in mucosa samples and on implant heads. Material and Methods: Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads. Results: In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP -MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group. Conclusions: Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy