SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Werner Sven 1952) srt2:(2015-2019)"

Sökning: WFRF:(Werner Sven 1952) > (2015-2019)

  • Resultat 1-10 av 36
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Averfalk, Helge, 1988-, et al. (författare)
  • Efficient heat distribution in solar district heating systems
  • 2018
  • Ingår i: SDH Solar District Heating. ; , s. 63-66
  • Konferensbidrag (refereegranskat)abstract
    • This paper contains a short analysis showing the main benefit for solar district heating when a novel heat distribution concept with low temperatures is applied. The analysis is performed by comparing the annual solar heat output from a solar collector field for current heat distribution temperatures in Sweden with the corresponding output for the novel heat distribution concept. The results show that the new low temperature concept provides 66% more solar heat for a typical solar collector. Hereby, the solar collector field can be reduced with 40%, giving a corresponding cost reduction for solar heat generated. Another result is that the cost gradient for lower costs from lower return temperatures is five times higher for solar district heating compared to current heat supply in Swedish district heating systems. One major conclusion is that high heat distribution temperatures in current European district heating systems are a major barrier for the competitiveness of solar district heating.
  •  
2.
  • Averfalk, Helge, 1988- (författare)
  • Enhanced District Heating Technology : Maintaining Future System Feasibility
  • 2017
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • When heat demand and high temperature heat supply gradually decreases in the future, then it will effect district heating systems ability to compete on the heat market. A good way to mitigate less district heating feasibility is to operate systems with lower temperature levels and the most conceivable way to achieve lower temperature levels is to decrease return temperatures.Thus, this thesis emphasise temperature errors embedded in district heating systems. Only a selection of temperature errors are analysed in this thesis. First, the temperature error that occurs due to recirculation in distribution networks at low heat demands. Second, the temperature error that occurs due to hot water circulation in multi-family buildings. Third, the temperature error that occurs due to less than possible heat transfer in heat exchangers, i.e. too short thermal lengths.In order to address these temperature errors three technology changes have been proposed (i) three-pipe distribution network to separate the recirculation return flow from the delivery return flow, (ii) apartment substations to eliminate hot water circulation utilisation, and (iii) improved heat exchangers for lower return temperatures at a constant scenario. Analysis of proposed changes has resulted in annual average return temperatures between 17-21 °C.Furthermore, rapid introduction of intermittent renewable electricity supply in the energy system has prompted an increased necessity of power system balancing capacities. Large-scale conversion of power-to-heat in electric boilers and heat pumps is a feasible alternative to achieve such balancing capacities. Analysis of the unique Swedish experience with utilisation of large heat pumps installations connected to district heating systems show that since the 1980s 1527 MW of heat power has been installed, about 80 % of the capacity was still in use by 2013. Thus, a cumulative value of over three decades of operation and maintenance exists within Swedish district heating systems.The two papers presented in this thesis are related to future district heating systems through the five abilities of fourth generation district heating (4GDH), which are documented in the definition paper of 4GDH.
  •  
3.
  • Averfalk, Helge, 1988-, et al. (författare)
  • Essential Improvements in Future District Heating Systems
  • 2016
  • Ingår i: Proceedings of the 15th International Symposium on District Heating and Cooling. ; , s. 194-200
  • Konferensbidrag (refereegranskat)abstract
    • The major common denominator for future efficient fourth generation district heating systems is lower temperature levels in the distribution networks. Higher efficiencies are then obtained in both heat supply and heat distribution. Heat supply becomes more efficient with respect to combined heat and power, flue gas condensation, heat pumps, geothermal extraction, low temperature excess heat, and heat storage. Heat distribution becomes more efficient from lower distribution losses, less pipe expansion, lower scalding risks, and plastic pipes. The lower temperature levels will be possible since future buildings will have lower temperature demands when requiring lower heat demands. This paper aims at providing seven essential recommendations concerning design and construction strategies for future fourth generation systems. The method used is based on a critical examination of the barriers for lower temperature levels and the origins of high return temperatures in contemporary third generation systems. The two main research questions applied are: Which parts of contemporary system design are undesirable? Which possible improvements are desirable? Key results and the corresponding recommendations include temperature levels for heat distribution, recirculation, metering, supervision, thermal lengths for heat exchangers and heat sinks, hydronic balancing, and legionella. The main conclusion is that it should be possible to construct new fourth generation district heating networks according to these seven essential recommendations presented in this paper.
  •  
4.
  • Averfalk, Helge, 1988-, et al. (författare)
  • Essential improvements in future district heating systems
  • 2017
  • Ingår i: Energy Procedia. - Amsterdam : Elsevier. - 1876-6102. ; 116, s. 217-225
  • Tidskriftsartikel (refereegranskat)abstract
    • The major common denominator for future efficient fourth generation district heating systems is lower temperature levels in the distribution networks. Higher efficiencies are then obtained in both heat supply and heat distribution. Heat supply becomes more efficient with respect to combined heat and power, flue gas condensation, heat pumps, geothermal extraction, low temperature excess heat, and heat storage. Heat distribution becomes more efficient from lower distribution losses, less pipe expansion, lower scalding risks, and plastic pipes. The lower temperature levels will be possible since future buildings will have lower temperature demands when requiring lower heat demands. This paper aims at providing seven essential recommendations concerning design and construction strategies for future fourth generation systems. The method used is based on a critical examination of the barriers for lower temperature levels and the origins of high return temperatures in contemporary third generation systems. The two main research questions applied are: Which parts of contemporary system design are undesirable? Which possible improvements are desirable? Key results and the corresponding recommendations include temperature levels for heat distribution, recirculation, metering, supervision, thermal lengths for heat exchangers and heat sinks, hydronic balancing, and legionella. The main conclusion is that it should be possible to construct new fourth generation district heating networks according to these seven essential recommendations presented in this paper. © 2017 The Authors. Published by Elsevier
  •  
5.
  •  
6.
  • Averfalk, Helge, 1988-, et al. (författare)
  • Large heat pumps in Swedish district heating systems
  • 2017
  • Ingår i: Renewable & sustainable energy reviews. - Kidlington : Pergamon Press. - 1364-0321 .- 1879-0690. ; 79, s. 1275-1284
  • Tidskriftsartikel (refereegranskat)abstract
    • Power-to-heat solutions like heat pumps and electric boilers are foreseen to be possible future tools to stabilise international power markets with high proportions of variable power supply. Temporary low cost electricity can be used for heat generation at times with high availability of wind and solar power through substitution of ordinary heat supply, hence contributing to increased energy system sustainability. Power-to-heat installations in district heating systems are competitive due to low specific investment and installation costs for large electric boilers, heat pumps, and heat storages. Several large-scale heat pumps were installed in Swedish district heating systems during the 1980s, since a national electricity surplus from new nuclear power existed for some years. The aim of this paper is to summarise the accumulated operation experiences from these large Swedish heat pumps to support and facilitate planning of future power-to-heat solutions with heat pumps in district heating systems. Gained experiences consider; installed capacities, capacity utilisation, heat sources used, refrigerant replacements, refrigerant leakages, and wear of mechanical components. The major conclusion is that many of the large thirty-year-old heat pumps are still in operation, but with reduced capacity utilisation due to internal competition from waste and biomass cogeneration plants in the district heating systems.
  •  
7.
  • Averfalk, Helge, 1988- (författare)
  • Low-temperature District Heating : Various Aspects of Fourth-generation Systems
  • 2019
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • With decreasing heat demand and less availability of high-temperature heat supply in future energy systems, the current district heating systems may experience increased competition on the heat market. A viable option to mitigate increasing competition is to operate systems with lower temperature levels, and the most conceivable way to achieve lower temperature levels is to decrease return temperatures.In this thesis, aspects of improvements in district heating systems are assessed. Three aspects, in particular, have been analysed. These are integration between energy systems, improvements in heat distribution technology, and economic benefits of low-temperature district heating systems.An increasing interest in integrating different energy systems has been prompted by the rapid introduction of intermittent renewable electricity supply in the energy system. Large-scale conversion of power to heat in electric boilers and heat pumps is a feasible alternative to achieve the balancing capacities required to maintain system functioning. Analysis of the unique Swedish experience using large heat-pump installations connected to district heating systems shows that, since the 1980s, 1527 MW of heat power has been installed, and about 80% of the capacity was still in use in 2013. Thus, a cumulative value of over three decades of operation and maintenance exists within Swedish district heating systems.Increased competition prompted by changes in the operation environment necessitates improved heat distribution. This thesis focuses on three system-embedded temperature errors: first, the temperature error that occurs due to recirculation in distribution networks at low heat demands; second, the temperature error that occurs due to hot-water circulation in multi-family buildings; third, the temperature error that occurs due to lower heat transfer than is possible in heat exchangers (i.e. too-short thermal length). To address these temperature errors, three technology changes have been proposed (i) a three-pipe distribution network to separate the recirculation return flow from the delivery return flow, (ii) apartment substations to eliminate hot-water circulation use, and (iii) improved heat exchangers for lower return temperatures. The analysis of the proposed changes indicates annual average return temperatures between 17°C and 21°C.The final analysed aspect is the economic benefits of low-temperature district heating. It was identified that strong economic motives for lower operating temperatures in future heat supply exist, whereas the economic motives are significantly weaker for the traditional heat supply.The five papers presented in this thesis are related to future district heating systems through the five abilities of fourth-generation district heating (4GDH), which are documented in the definition paper on 4GDH.
  •  
8.
  • Averfalk, Helge, 1988-, et al. (författare)
  • Novel low temperature heat distribution technology
  • 2018
  • Ingår i: Energy. - London : Elsevier. - 0360-5442 .- 1873-6785. ; 145, s. 526-539
  • Tidskriftsartikel (refereegranskat)abstract
    • Lower future heat demands and lower availability of non-fossil high temperature heat supply are expected future market conditions that restrain the long-term viability of contemporary district heating systems. Hence, current district heating technology should be enhanced to increase system performance in new heat distribution areas. This paper aims to outline a proposal for technical improvements required to achieve lower annual average return temperatures in new residential buildings to improve viability in future market conditions. The proposed technical solution consists of three principle changes: three-pipe distribution networks, apartment substations, and longer thermal lengths for heat exchangers. The three technical modifications aims at addressing system embedded temperature errors. Furthermore, a simulation model was developed to assess the proposed technical solution concerning different energy performances of buildings and different thermal lengths in heat exchangers. The results show that implementation of the three technical modifications reaches time-weighted annual average return temperatures of 17–21 °C with supply temperatures of about 50 °C. The results also verify the increased necessity to separate the network return flows into delivery and recirculation flows in residential substations as energy performance in buildings increase.
  •  
9.
  • Averfalk, Helge, 1988-, et al. (författare)
  • Pipe Sizing for Novel Heat Distribution Technology
  • 2019
  • Ingår i: Energies. - Basel : MDPI. - 1996-1073. ; 12:7
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper assesses pipe sizing aspects for previously proposed, novel, low heat distribution technology with three pipes. Assessment issues include heat loss, pressure loss, and pipe sizing for different typical pipe configurations. This assessment has been provided by the analysis of a case area with single-family houses. Concerning heat loss, the proposed three-pipe solutions have the same magnitude of heat loss as conventional twin pipes, since lower return temperatures compensate for the larger heat loss area from the third pipe. Regarding pressure loss, the main restriction on the size of the third pipe is limited to the pressure loss in the third pipe. Thermostatic valves to manage the flow rate of the third pipe are advocated, since alternative small pumps have not been found to be commercially available. The pipe sizing recommendation is that the third pipe for recirculation purposes can be two to three standard pipe sizes smaller than the corresponding supply and return pipe, if no prosumer is connected in the heat distribution network.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 36
Typ av publikation
tidskriftsartikel (19)
rapport (7)
konferensbidrag (5)
bok (1)
doktorsavhandling (1)
forskningsöversikt (1)
visa fler...
bokkapitel (1)
licentiatavhandling (1)
visa färre...
Typ av innehåll
refereegranskat (27)
övrigt vetenskapligt/konstnärligt (9)
Författare/redaktör
Werner, Sven, 1952- (23)
Werner, Sven, Profes ... (13)
Averfalk, Helge, 198 ... (11)
Gong, Mei, 1967- (7)
Lygnerud, Kristina, ... (5)
Sernhed, Kerstin (2)
visa fler...
Persson, Urban, Dr. ... (2)
Persson, Urban, 1961 ... (2)
Svendsen, Svend (2)
Ericsson, Karin (2)
Lauenburg, Patrick (2)
Gadd, Henrik, 1967- (2)
Lund, Henrik (2)
Möller, Bernd (2)
Nowaczyk, Sławomir, ... (1)
Lennermo, Gunnar (1)
Ödlund, Louise, Prof ... (1)
Pinheiro Sant'Anna, ... (1)
Ottermo, Fredric, 19 ... (1)
Lauenburg, Patrick, ... (1)
Sernhed, Kerstin, As ... (1)
Johansson Kallioniem ... (1)
Ingvarsson, Paul (1)
Elmegaard, Brian, Pr ... (1)
Felsmann, Clemens (1)
Rühling, Karin (1)
Wiltshire, Robin (1)
Li, Hongwei (1)
Faessler, Jérôme (1)
Floriane, Mermoud (1)
Quiquerez, Loïc (1)
Calikus, Ece, 1990- (1)
Mathiesen, Brian Vad (1)
Østergaard, Poul Alb ... (1)
Vad Mathiesen, Brian (1)
David, Andrei (1)
Duic, Neven (1)
Gadd, Henrik (1)
Zhang, Xiliang (1)
Hvelplund, Frede (1)
Thorsen, Jan Eric (1)
Chang, Miguel (1)
Sorknæs, Peter (1)
Mortensen, Bent Ole ... (1)
Bojesen, Carsten (1)
Wiechers, Eva (1)
visa färre...
Lärosäte
Högskolan i Halmstad (36)
Lunds universitet (4)
Mälardalens universitet (1)
Språk
Engelska (34)
Svenska (2)
Forskningsämne (UKÄ/SCB)
Teknik (36)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy