SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wikberg J)
 

Sökning: WFRF:(Wikberg J) > (2020-2021) > IMPROVEMENTS OF (IN...

IMPROVEMENTS OF (IN)-I-111 SPECT IMAGES RECONSTRUCTED WITH SPARSELY ACQUIRED PROJECTIONS BY DEEP LEARNING GENERATED SYNTHETIC PROJECTIONS

Ryden, T. (författare)
Wikberg, Emma (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
Van Essen, M. (författare)
visa fler...
Svensson, J. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för onkologi,Institute of Clinical Sciences, Department of Oncology
Bernhardt, Peter, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
visa färre...
 (creator_code:org_t)
2021-04-22
2021
Engelska.
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 195:3-4, s. 152-157
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim was to improve single-photon emission computed tomography (SPECT) quality for sparsely acquired In-111 projections by adding deep learning generated synthetic intermediate projections (SIPs). Method: The recently constructed deep convolutional network for generating synthetic intermediate projections (CUSIP) was used for improving 20 sparsely acquired In-111-octreotide SPECTs. Reconstruction was performed with 120 (120P) or 30 (30P) projections, or 120 projections with 90 SIPs generated from 30 projections (30-120SIP). The SPECT reconstructions were performed with attenuation, scatter and collimator response corrections. Postfiltered 30P reconstructed SPECT was also analyzed. Image quality were quantitatively evaluated with root-mean-square error, peak signal-to-noise ratio and structural similarity index metrics. Result: The 30-120SIP reconstructed SPECT had statistically significant improved image quality parameters compared to 30P reconstructed SPECT with and without post filtering. The images visual appearance was similar to slightly filtered 120P SPECTs. Thereby, substantial acquisition time reduction with SIPs seems possible without image quality degradation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Environmental Sciences & Ecology
Public
Environmental & Occupational
Health
Nuclear Science & Technology
Radiology
Medical Imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ryden, T.
Wikberg, Emma
Van Essen, M.
Svensson, J.
Bernhardt, Peter ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation Protec ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy