SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Yokota N) srt2:(2005-2009)"

Sökning: WFRF:(Yokota N) > (2005-2009)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Milz, Mathias, et al. (författare)
  • Validation of water vapour profiles (version 13) retrieved by the IMK/IAA scientific retrieval processor based on full resolution spectra measured by MIPAS on board Envisat
  • 2009
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 2:2, s. 379-399
  • Tidskriftsartikel (refereegranskat)abstract
    • Vertical profiles of stratospheric water vapour measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) with the full resolution mode between September 2002 and March 2004 and retrieved with the IMK/IAA scientific retrieval processor were compared to a number of independent measurements in order to estimate the bias and to validate the existing precision estimates of the MIPAS data. The estimated precision for MIPAS is 5 to 10% in the stratosphere, depending on altitude, latitude, and season. The independent instruments were: the Halogen Occultation Experiment (HALOE), the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS), the Improved Limb Atmospheric Spectrometer-II (ILAS-II), the Polar Ozone and Aerosol Measurement (POAM III) instrument, the Middle Atmospheric Water Vapour Radiometer (MIAWARA), the Michelson Interferometer for Passive Atmospheric Sounding, balloon-borne version (MIPAS-B), the Airborne Microwave Stratospheric Observing System(AMSOS), the Fluorescent Stratospheric Hygrometer for Balloon (FLASH-B), the NOAA frostpoint hygrometer, and the Fast In Situ Hygrometer (FISH). For the in-situ measurements and the ground based, air- and balloon borne remote sensing instruments, the measurements are restricted to central and northern Europe. The comparisons to satellite-borne instruments are predominantly at mid- to high latitudes on both hemispheres. In the stratosphere there is no clear indicationof a bias in MIPAS data, because the independent measurements in some cases are drier and in some cases are moister than the MIPAS measurements. Compared to the infrared measurements of MIPAS, measurements in the ultraviolet and visible have a tendency to be high, whereas microwave measurements have a tendency to be low. Theresults of chi2-based precision validation are somewhat controversial among the comparison estimates. However, for comparison instruments whose error budget also includes errors due to uncertainties in spectrally interfering species and where good coincidences were found, the chi2 values found are in the expected range or even below. This suggests that there is no evidence of systematically underestimated MIPAS random errors.
  •  
2.
  • Ejiri, M.K., et al. (författare)
  • Validation of the Improved Limb Atmospheric Spectrometer-II (ILAS-II) Version 1.4 nitrous oxide and methane profiles
  • 2006
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 111:D22
  • Tidskriftsartikel (refereegranskat)abstract
    • This study assesses polar stratospheric nitrous oxide (N(2)O) and methane (CH(4)) data from the Improved Limb Atmospheric Spectrometer-II (ILAS-II) on board the Advanced Earth Observing Satellite-II (ADEOS-II) retrieved by the Version 1.4 retrieval algorithm. The data were measured between January and October 2003. Vertical profiles of ILAS-II volume mixing ratio (VMR) data are compared with data from two balloon-borne instruments, the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS-B) and the MkIV instrument, as well as with two satellite sensors, the Odin Sub-Millimetre Radiometer (SMR) for N(2)O and the Halogen Occultation Experiment (HALOE) for CH(4). Relative percentage differences between the ILAS-II and balloon/satellite data and their median values are calculated in 10-ppbv-wide bins for N(2)O (from 0 to 400 ppbv) and in 0.05-ppmv-wide bins for CH(4) (from 0 to 2 ppmv) in order to assess systematic differences between the ILAS-II and balloon/satellite data. According to this study, the characteristics of the ILAS-II Version 1.4 N(2)O and CH(4) data differ between hemispheres. For ILAS-II N(2)O VMR larger than 250 ppbv, the ILAS-II N(2)O agrees with the balloon/SMR N(2)O within +/- 20% in both hemispheres. The ILAS-II N(2)O in the VMR range from 30-50 to 250 ppbv (corresponding to altitudes of similar to 17-30 km in the Northern Hemisphere (NH, mainly outside the polar vortex) and similar to 13-21 km in the Southern Hemisphere (SH, mainly inside the polar vortex) is smaller by similar to 10-30% than the balloon/SMR N(2)O. For ILAS-II N(2)O VMR smaller than 30 ppbv (>similar to 21 km) in the SH, the differences between the ILAS-II and SMR N(2)O are within +/- 10 ppbv. For ILAS-II CH(4) VMR larger than 1 ppmv (similar to 30 km) and the ILAS-II CH(4) for its VMR smaller than 1 ppmv (>similar to 25 km) only in the NH, are abnormally small compared to the balloon/satellite data.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy