SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Yousry Tarek) srt2:(2010-2014)"

Sökning: WFRF:(Yousry Tarek) > (2010-2014)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Zrinzo, Ludvic, et al. (författare)
  • Clinical safety of brain magnetic resonance imaging with implanted deep brain stimulation hardware : large case series and review of the literature
  • 2011
  • Ingår i: World Neurosurgery. - New York, NY : Elsevier. - 1878-8750. ; 76:1-2, s. 164-172
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Over 75,000 patients have undergone deep brain stimulation (DBS) procedures worldwide. Magnetic resonance imaging (MRI) is an important clinical and research tool in analyzing electrode location, documenting postoperative complications, and investigating novel symptoms in DBS patients. Functional MRI may shed light on the mechanism of action of DBS. MRI safety in DBS patients is therefore an important consideration. Methods: We report our experience with MRI in patients with implanted DBS hardware and examine the literature for clinical reports on MRI safety with implanted DBS hardware. Results: A total of 262 MRI examinations were performed in 223 patients with intracranial DBS hardware, including 45 in patients with an implanted pulse generator. Only 1 temporary adverse event occurred related to patient agitation and movement during immediate postoperative MR imaging. Agitation resolved after a few hours, and an MRI obtained before implanted pulse generator implantation revealed edema around both electrodes. Over 4000 MRI examinations in patients with implanted DBS hardware have been reported in the literature. Only 4 led to adverse events, including 2 hardware failures, 1 temporary and 1 permanent neurological deficit. Adverse neurological events occurred in a unique set of circumstances where appropriate safety protocols were not followed. MRI guidelines provided by DBS hardware manufacturers are inconsistent and vary among devices. Conclusions: The importance of MRI in modern medicine places pressure on industry to develop fully MRI-compatible DBS devices. Until then, the literature suggests that, when observing certain precautions, cranial MR images can be obtained with an extremely low risk in patients with implanted DBS hardware.
  •  
2.
  • Zrinzo, Ludvic, et al. (författare)
  • Targeting of the pedunculopontine nucleus by an MRI-guided approach : a cadaver study
  • 2011
  • Ingår i: Journal of neural transmission. - Wien : Springer. - 0300-9564 .- 1435-1463. ; 118:10, s. 1487-1495
  • Tidskriftsartikel (refereegranskat)abstract
    • Laboratory evidence suggests that the pedunculopontine nucleus (PPN) plays a central role in the initiation and maintenance of gait. Translational research has led to reports on deep brain stimulation (DBS) of the rostral brainstem in parkinsonian patients. However, initial clinical results appear to be rather variable. Possible factors include patient selection and the wide variability in anatomical location of implanted electrodes. Clinical studies on PPN DBS efficacy would, therefore, benefit from an accurate and reproducible method of stereotactic localization of the nucleus. The present study evaluates the anatomical accuracy of a specific protocol for MRI-guided stereotactic targeting of the PPN in a human cadaver. Imaging at 1.5 and 9.4 T confirmed electrode location in the intended region as defined anatomically by the surrounding fiber tracts. The spatial relations of each electrode track to the nucleus were explored by subsequent histological examination. This confirmed that the neuropil surrounding each electrode track contained scattered large neurons morphologically consistent with those of the subnucleus dissipatus and compactus of the PPN. The results support the accuracy of the described specific MR imaging protocol.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy