SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Zhang Yuanyuan)
 

Sökning: WFRF:(Zhang Yuanyuan) > (2001-2004) > The geometric desig...

The geometric design of micromachined silicon sieve electrodes influences functional nerve regeneration

Wallman, Lars (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Neuronano Research Center (NRC),Forskargrupper vid Lunds universitet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups
Zhang, Yuanyuan (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Laurell, Thomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Danielsen, Nils (författare)
Lund University,Lunds universitet,Neurala gränsytor,Forskargrupper vid Lunds universitet,Neuronano Research Center (NRC),Neural Interfaces,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2001
2001
Engelska.
Ingår i: Biomaterials. - 1878-5905. ; 22:10, s. 1187-1193
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A neural interface could be used to control a limb prosthesis. Such an interface can be created by facilitating axonal regeneration through a sieve electrode and then register nerve signals intended to control the prosthesis. A key question is how to design the electrodes to ensure the best possible regeneration. Our previous studies have indicated that regeneration can be achieved using electrodes with square-shaped, 100×100 μm, via holes (holes that axons will regenerate through). Other reports have indicated a suitable range of these holes between 40 and 65 μm. In the present study we used silicon sieve electrodes with via holes of either 30 or 90 μm. The transparency, i.e. the percentage of the total via hole area, of these electrodes was either 20 or 30%. The electrodes were inserted into a silicone chamber which was used to bridge a gap in a rat sciatic nerve. After 12 weeks of nerve regeneration electrodes with a hole size of 30 μm and a 30% transparency had the most favourable result as judged by the regained gastrocnemius muscle force and the formation of reactive tissue inside the chamber. The sieve electrode transparency is crucial for ensuring regeneration.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik -- Bioteknisk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology -- Bioengineering Equipment (hsv//eng)

Nyckelord

Silicon
Nerve regeneration
Rat sciatic nerve
Sieve electrode

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wallman, Lars
Zhang, Yuanyuan
Laurell, Thomas
Danielsen, Nils
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Industriell biot ...
och Bioteknisk appar ...
Artiklar i publikationen
Biomaterials
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy