SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zito M.) srt2:(2006-2009)"

Sökning: WFRF:(Zito M.) > (2006-2009)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Frisoni, Giovanni B, et al. (författare)
  • The pilot European Alzheimer's Disease Neuroimaging Initiative of the European Alzheimer's Disease Consortium.
  • 2008
  • Ingår i: Alzheimer's & dementia : the journal of the Alzheimer's Association. - : Wiley. - 1552-5279. ; 4:4, s. 255-64
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In North America, the Alzheimer's Disease Neuroimaging Initiative (ADNI) has established a platform to track the brain changes of Alzheimer's disease. A pilot study has been carried out in Europe to test the feasibility of the adoption of the ADNI platform (pilot E-ADNI). METHODS: Seven academic sites of the European Alzheimer's Disease Consortium (EADC) enrolled 19 patients with mild cognitive impairment (MCI), 22 with AD, and 18 older healthy persons by using the ADNI clinical and neuropsychological battery. ADNI compliant magnetic resonance imaging (MRI) scans, cerebrospinal fluid, and blood samples were shipped to central repositories. Medial temporal atrophy (MTA) and white matter hyperintensities (WMH) were assessed by a single rater by using visual rating scales. RESULTS: Recruitment rate was 3.5 subjects per month per site. The cognitive, behavioral, and neuropsychological features of the European subjects were very similar to their U.S. counterparts. Three-dimensional T1-weighted MRI sequences were successfully performed on all subjects, and cerebrospinal fluid samples were obtained from 77%, 68%, and 83% of AD patients, MCI patients, and controls, respectively. Mean MTA score showed a significant increase from controls (left, right: 0.4, 0.3) to MCI patients (0.9, 0.8) to AD patients (2.3, 2.0), whereas mean WMH score did not differ among the three diagnostic groups (between 0.7 and 0.9). The distribution of both MRI markers was comparable to matched US-ADNI subjects. CONCLUSIONS: Academic EADC centers can adopt the ADNI platform to enroll MCI and AD patients and older controls with global cognitive and structural imaging features remarkably similar to those of the US-ADNI.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy