SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zucchelli G. C.) srt2:(2015-2019)"

Sökning: WFRF:(Zucchelli G. C.) > (2015-2019)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aaltonen, T., et al. (författare)
  • Tevatron Constraints on Models of the Higgs Boson with Exotic Spin and Parity Using Decays to Bottom-Antibottom Quark Pairs
  • 2015
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 114:15
  • Tidskriftsartikel (refereegranskat)abstract
    • Combined constraints from the CDF and D0 Collaborations on models of the Higgs boson with exotic spin J and parity P are presented and compared with results obtained assuming the standard model value J(P) = 0(+). Both collaborations analyzed approximately 10 fb(-1) of proton-antiproton collisions with a center-of-mass energy of 1.96 TeV collected at the Fermilab Tevatron. Two models predicting exotic Higgs bosons with J(P) = 0(-) and J(P) = 2(+) are tested. The kinematic properties of exotic Higgs boson production in association with a vector boson differ from those predicted for the standard model Higgs boson. Upper limits at the 95% credibility level on the production rates of the exotic Higgs bosons, expressed as fractions of the standard model Higgs boson production rate, are set at 0.36 for both the J(P) = 0(-) hypothesis and the J(P) = 2(+) hypothesis. If the production rate times the branching ratio to a bottom-antibottom pair is the same as that predicted for the standard model Higgs boson, then the exotic bosons are excluded with significances of 5.0 standard deviations and 4.9 standard deviations for the J(P) = 0(-) and J(P) = 2(+) hypotheses, respectively.
  •  
2.
  • Aaltonen, T., et al. (författare)
  • Tevatron Run II combination of the effective leptonic electroweak mixing angle
  • 2018
  • Ingår i: Physical Review D. - : AMER PHYSICAL SOC. - 2470-0010 .- 2470-0029. ; 97:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Drell-Yan lepton pairs produced in the process p (p) over bar -> l(+)l(-) + X through an intermediate gamma*/Z boson have an asymmetry in their angular distribution related to the spontaneous symmetry breaking of the electroweak force and the associated mixing of its neutral gauge bosons. The CDF and D0 experiments have measured the effective-leptonic electroweak mixing parameter sin(2) theta(lept)(eff) using electron and muon pairs selected from the full Tevatron proton-antiproton data sets collected in 2001-2011, corresponding to 9-10 fb(-1) of integrated luminosity. The combination of these measurements yields the most precise result from hadron colliders, sin(2)theta(lept)(eff) = 0.23148 +/- 0.00033. This result is consistent with, and approaches in precision, the best measurements from electron-positron colliders. The standard model inference of the on-shell electroweak mixing parameter sin(2) theta(W), or equivalently the W-boson mass M-W, using the ZFITTER software package yields sin(2) theta(W) = 0.22324 +/- 0.00033 or equivalently, M-W = 80.367 +/- 0.017 GeV/c(2).
  •  
3.
  • Aaltonen, T., et al. (författare)
  • Combined Forward-Backward Asymmetry Measurements in Top-Antitop Quark Production at the Tevatron
  • 2018
  • Ingår i: Physical Review Letters. - : AMER PHYSICAL SOC. - 0031-9007 .- 1079-7114. ; 120:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The CDF and D0 experiments at the Fermilab Tevatron have measured the asymmetry between yields of forward- and backward-produced top and antitop quarks based on their rapidity difference and the asymmetry between their decay leptons. These measurements use the full data sets collected in proton-antiproton collisions at a center-of-mass energy of root s = 1.96 TeV. We report the results of combinations of the inclusive asymmetries and their differential dependencies on relevant kinematic quantities. The combined inclusive asymmetry is A(FB)(t (t) over bar) = 0.128 +/- 0.025. The combined inclusive and differential asymmetries are consistent with recent standard model predictions.
  •  
4.
  • Checchi, V., et al. (författare)
  • Wide diameter immediate post-extractive implants vs delayed placement of normal-diameter implants in preserved sockets in the molar region: 1-year postloading outcome of a randomised controlled trial
  • 2017
  • Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 10:3, s. 263-278
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare the effectiveness of 6.0 to 8.0 mm-wide diameter implants, placed immediately after tooth extraction, with conventional 4.0 or 5.0 mm diameter implants placed in a preserved socket after a 4-month period of healing in the molar region. Materials and Methods: Just after extraction of one or two molar teeth, and with no vertical loss of the buccal bone in relation to the palatal wall, 100 patients requiring immediate post-extractive implants were randomly allocated to immediate placement of one or two 6.0 to 8.0 mm-wide diameter implants (immediate group; 50 patients) or for socket preservation using a porcine bone substitute covered by a resorbable collagen barrier (delayed group; 50 patients), according to a parallel group design in one centre. Bone-to-implant gaps were filled with autogenous bone retrieved with a trephine drill used to prepare the implant sites for the immediate wide diameter post-extractive implants. Four months after socket preservation, one to two 4.0 or 5.0 mm-wide delayed implants were placed. Implants were loaded 4 months after placement with fixed provisional restorations in acrylic, and replaced after 4 months by fixed, definitive, metal-ceramic restorations. Patients were followed to 1 year after loading. Outcome measures were: implant failures, complications, aesthetics assessed using the pink esthetic score (PES), peri-implant marginal bone level changes, patient satisfaction, number of appointments and surgical interventions recorded, when possible, by blinded assessors. Results: Three patients dropped out 1 year after loading from the immediate group vs six from the delayed group. Five implants out of 47 failed in the immediate group (10.6%) vs two out 44 (4.6%) in the delayed group, the difference being not statistically significant (difference in proportion = 6.0%, 95% CI: -8.8% to 20.8%, P = 0.436). In the immediate group 10 patients were affected by 10 complications, while in the delayed group four patients were affected by four complications. The difference was not statistically significant (difference in proportion = 12%, 95% CI: -2% to 26%, P = 0.084). At delivery of the definitive prostheses, 4 months after loading, the mean total PES score was 9.65 ± 1.62 and 10.44 ± 1.47 in the immediate and delayed groups, respectively. At 1 year after loading, the mean total PES score was 9.71 ± 2.71 and 10.86 ± 1.37 in the immediate and delayed groups, respectively. The Total PES score was statistically significantly better at delayed implants both at 4 months (mean difference = 0.79; 95% CI: 0.05 to 1.53; P = 0.03) and at 1 year (mean difference = 1.15; 95% CI: 0.13 to 2.17; P = 0.02). Marginal bone levels at implant insertion (after bone grafting) were 0.04 mm for immediate and 0.11 mm for delayed implants, which was statistically significantly different (mean difference = 0.07; 95% CI: 0.02 to 0.12; P < 0.0001). One year after loading, patients in the immediate group lost on average 1.06 mm and those from the delayed group 0.63 mm, the difference being statistically significant (mean difference = 0.43 mm; 95% CI: 0.15 to 0.61; P < 0.0001). All patients were fully or partially satisfied both for function and aesthetics, and would undergo the same procedure again both at 4 months and 1 year after loading. Patients from the immediate group required on average 7.48 ± 1.45 visits to the clinician and 2.14 ± 0.49 surgical interventions and to have their definitive prostheses delivered vs 10.30 ± 0.99 visits and 3.08 ± 0.40 surgical interventions for the delayed group, the difference being statistically significant (P < 0.001 for visits, and P < 0.001 for surgical interventions). Conclusions: Preliminary 1 year follow-up data suggest that immediate placement of 6.0 to 8.0 mm wide diameter implants in molar extraction sockets yielded inferior aesthetic outcomes than ridge preservation and delayed placement of conventional 4.0 to 5.0 mm diameter implants. Conflict of interest statement: This trial was partially funded by the manufacturer of the implants evaluated in his investigation (MegaGen Implant Co, Gyeongbuk, South Korea). However, data belonged to the authors and in no way did the manufacturer interfere with the conduct of the trial or the publication of its results. © Quintessenz.
  •  
5.
  • Esposito, Marco, 1965, et al. (författare)
  • Immediate, immediate-delayed (6 weeks) and delayed (4 months) post-extractive single implants: 1-year post-loading data from a randomised controlled trial
  • 2017
  • Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 10:1, s. 11-26
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare the clinical outcome of single implants placed immediately after tooth extraction with implants placed 6 weeks after tooth extraction (immediate-delayed placement), and with implants placed after 4-month extraction and socket healing (delayed placement). Materials and methods: Two-hundred and ten (210) patients requiring a single implant-supported crown to replace a tooth to be extracted were randomised to receive immediate post-extractive implants (70 patients), immediate-delayed implants at 6 weeks (70 patients), and delayed implants after 4 months of healing (70 patients) according to a parallel group design. When needed, patients of the immediate and immediate-delayed group had the socket grafted with a bone substitute and covered with a resorbable membrane at implant placement. Sockets randomised to delayed implants were grafted in the same manner if poorly preserved or in the aesthetic areas (from second upper to second upper premolars). Implants inserted with at least 25 Ncm torque were left to heal unloaded for 4 months, whereas those inserted with less than 25 Ncm were left to heal unloaded for 6 months. Temporary crowns were delivered and were to be replaced by definitive ones after 4 months. Outcome measures were crown and implant failures, complications, peri-implant marginal bone level changes, aesthetically assessed using the pink esthetic score (PES), and patient satisfaction recorded by blinded assessors. Patients were followed up to 1 year post-loading. Results: One year after loading, three patients dropped out from the immediate group, five from the immediate-delayed group, and six from the delayed group. Four implants (6%) failed in the immediate, four (6.2%) in the immediate-delayed, and one (1.6%) from the delayed group (P (chisquare test) = 0.369). Apart from the crowns (which failed due to implant losses), no other crown had to be remade. Six immediate, six immediate-delayed and four delayed implants were affected by one complication each (P (chi-square test) = 0.792). Mean peri-implant marginal bone loss after 1 year was-0.25 +/- 0.17 mm (CI 95%-0.29; -0.20) at immediate,-0.29 +/- 0.14 mm (CI 95% -0.32; -0.25) at immediate-delayed, and-0.31 +/- 0.16 mm (Cl 95%-0.35; -0.27) at delayed placed implants (P (Kruskal-Wallis test) = 0.015). One year after loading, the mean total aesthetic score was 12.52, 12.49 and 11.78 at the immediate, immediate-delayed and delayed groups, respectively (P (Kruskal-Wallis test) < 0.001). All patients were fully satisfied both with function and aesthetics, and would undergo the same procedure again, with four exceptions (one from the immediate, one from the immediate-delayed and two from the delayed group), who were only partially satisfied with aesthetics (P = 0.785). Conclusions: No statistically significant differences for failures, complications and patient satisfaction were observed when placing single implants immediately, 6 weeks or 4 months after tooth extraction; nevertheless, failures were more frequent at immediate and immediate-delayed placed implants. Bone level changes were similar between the different procedures, but aesthetics were better results at immediate and immediate-delayed implants.
  •  
6.
  • Felice, P., et al. (författare)
  • Immediate, immediate-delayed (6 weeks) and delayed (4 months) post-extractive single implants: 4-month post-loading data from a randomised controlled trial
  • 2016
  • Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 9:3, s. 233-247
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare the clinical outcome of single implants placed immediately after tooth extraction with implants placed 6 weeks after tooth extraction (immediate-delayed placement), and with implants placed after 4 months of extraction and socket healing (delayed placement). Materials and methods: Two hundred and ten patients requiring a single implant-supported crown to replace a tooth to be extracted were randomised to receive immediate post-extractive implants (70 patients), immediate-delayed implants at 6 weeks (70 patients), and delayed implants after 4 months of healing (70 patients), according to a parallel group design. When needed, patients of the immediate and immediate-delayed group had the socket grafted with a bone substitute and covered with a resorbable membrane at implant placement. Sockets randomised to delayed implants were grafted in the same manner if poorly preserved or in the aesthetic areas (from second upper to second upper premolars). Implants inserted with at least 25 Ncm torque were left to heal unloaded for 4 months, whereas those inserted with less than 25 Ncm were left to heal unloaded for 6 months. Temporary crowns were delivered and were to be replaced by definitive ones after 4 months. Outcome measures were crown and implant failures, complications, periimplant marginal bone level changes, aesthetics assessed using the pink esthetic score (PES) and patient satisfaction recorded by blinded assessors. Results: Three patients dropped out from the immediate, five from the immediate-delayed and six from the delayed group up to 4-months post-loading. Four implants (6.0%) failed in the immediate, four (6.2%) in the immediate-delayed and one (1.6%) from the delayed group (P (chi-square test) = 0.369). Apart from the crown failures due to implant losses, no other crown had to be remade. Five immediate, six immediate-delayed and three delayed implants were affected by one complication each (P (chi-square test) = 0.601). Mean peri-implant marginal bone loss after 4 months was -0.17 +/- 0.11 mm (95% CI: -0.20; -0.15) at immediate, -0.20 +/- 0.09 mm (95% CI: -0.23; -0.18) at immediate-delayed, and -0.24 +/- 0.12 mm (95% CI: -0.27; -0.21) at delayed placed implants (P (Kruskal Wallis test) = 0.006). At delivery of definitive crowns, 4 months after loading, the mean total aesthetic score was 12.48, 12.38 and 11.71 in the immediate, immediate-delayed and delayed groups, respectively (P (Kruskal Wallis test) < 0.001). All patients were fully satisfied with both function and aesthetics, and would undergo the same procedure again, with four exceptions (one from the immediate, one from the immediate-delayed and two from the delayed group), who were partially satisfied with the aesthetics (P = 0.785). Conclusions: No statistically significant differences for failures, complications and patient satisfaction were observed when placing single implants immediately, 6 weeks or four months after tooth extraction; nevertheless failures and complications were more frequent for immediate and immediate-delayed placed implants. Bone level changes were similar between the different procedures, but the aesthetics showed better results for immediate and immediate-delayed implants.
  •  
7.
  • Esposito, Marco, 1965, et al. (författare)
  • Four mm-long versus longer implants in augmented bone in atrophic posterior jaws: 4-month post-loading results from a multicentre randomised controlled trial
  • 2016
  • Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 9:4, s. 393-409
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate whether 4-mm long dental implants could be an alternative to augmentation with equine bone blocks and the placement of at least 10-mm long implants in atrophic posterior jaws. Materials and methods: Forty patients with atrophic posterior (premolar and molar areas) mandibles having 5 to 6 mm bone height above the mandibular canal and 40 patients with atrophic maxillae having 4 to 5 mm below the maxillary sinus, were randomised according to a parallel group design to receive one to three 4.0 mm-long implants or one to three implants, which were at least 10 mm long, in augmented bone at two centres. All implants had a diameter of 4.0 or 4.5 mm. Mandibles were vertically augmented with interpositional equine bone blocks and resorbable barriers. Implants were placed 4 months after interpositional grafting. Maxillary sinuses were augmented with particulated porcine bone via a lateral window covered with resorbable barriers, and implants were placed simultaneously. Implants were not submerged and were loaded after 4 months with provisional prostheses. Four months later, screw-retained reinforced acrylic restorations were delivered, and then replaced after 4 months by definitive screw-retained metal-composite prostheses. Patients were followed up to 4-months post-loading. Outcome measures included prosthesis and implant failures, any complication and peri-implant marginal bone level changes. Results: No patient dropped out. In six augmented mandibles (30%), it was not possible to place implants which were at least 10.0-mm long, therefore shorter implants had to be placed instead. In particular, one mandible fractured and the patient did not want to go ahead with the treatment. One implant of the patient with the mandible fracture from the augmented group failed versus two 4.0 mm implants in two patients from the short implant group. In the maxillae, three short implants failed in two patients versus five long implants in three patients (two long implants and one short implant dropped into the maxillary sinus). Two prostheses on short implants (one mandibular and one maxillary) were placed at a later stage because of implant failures versus four prostheses (one mandibular and three maxillary) at augmented sites. In particular, three patients of the augmented group (one mandible and two maxillary) were not prosthetically rehabilitated. There were no statistically significant differences in implant failures (P (chi-square test) = 1.000; difference in proportion = 0; 95% CI:-0.13 to 0.13 or prostheses failures (P (chi-square test) = 0.399; difference in proportion = 0.05; 95% CI:-0.06 to 0.16). At mandibular sites, nine augmented patients were affected by complications versus one patient treated with short implants (P (chi-square test) = 0.003; difference in proportion = 0.40; 95% CI: 0.16 to 0.64), with the difference being statistically significant. No significant differences were found for the maxillae: eight sinus lift patients versus three patients rehabilitated with maxillary short implants were affected by complications (P (chi-square test) = 0.077; difference in proportion = 0.25; 95% CI:-0.02 to 0.52). Patients with mandibular short implants lost on average 0.40 mm of peri-implant bone at 4 months and patients with 10 mm or longer mandibular implants lost 0.52 mm. Patients with short maxillary implants lost on average 0.48 mm peri-implant bone at 4 months and patients with 10 mm or longer maxillary implants lost 0.50 mm. The difference was statistically significant in the mandibles (mean difference: -0.12 mm, 95% CI: -0.20 to -0.04, P (ANCOVA) = 0.006), but not in the maxillae (mean difference: -0.02 mm, 95% CI: -0.10 to 0.07, P (ANCOVA) = 0.711). Conclusions: Four months after loading 4.0 mm-long implants achieved similar results, if not better, than longer implants in augmented jaws, but were affected by fewer complications. Short implants might be a preferable choice to bone augmentation, especially in mandibles, since the treatment is less invasive, faster, cheaper, and associated with less morbidity; however, 5- to 10-year post-loading data is necessary before making reliable recommendations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy