SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zucchelli M) srt2:(2015-2018)"

Sökning: WFRF:(Zucchelli M) > (2015-2018)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aaltonen, T., et al. (författare)
  • Tevatron Run II combination of the effective leptonic electroweak mixing angle
  • 2018
  • Ingår i: Physical Review D. - : AMER PHYSICAL SOC. - 2470-0010 .- 2470-0029. ; 97:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Drell-Yan lepton pairs produced in the process p (p) over bar -> l(+)l(-) + X through an intermediate gamma*/Z boson have an asymmetry in their angular distribution related to the spontaneous symmetry breaking of the electroweak force and the associated mixing of its neutral gauge bosons. The CDF and D0 experiments have measured the effective-leptonic electroweak mixing parameter sin(2) theta(lept)(eff) using electron and muon pairs selected from the full Tevatron proton-antiproton data sets collected in 2001-2011, corresponding to 9-10 fb(-1) of integrated luminosity. The combination of these measurements yields the most precise result from hadron colliders, sin(2)theta(lept)(eff) = 0.23148 +/- 0.00033. This result is consistent with, and approaches in precision, the best measurements from electron-positron colliders. The standard model inference of the on-shell electroweak mixing parameter sin(2) theta(W), or equivalently the W-boson mass M-W, using the ZFITTER software package yields sin(2) theta(W) = 0.22324 +/- 0.00033 or equivalently, M-W = 80.367 +/- 0.017 GeV/c(2).
  •  
2.
  • Aaltonen, T., et al. (författare)
  • Combined Forward-Backward Asymmetry Measurements in Top-Antitop Quark Production at the Tevatron
  • 2018
  • Ingår i: Physical Review Letters. - : AMER PHYSICAL SOC. - 0031-9007 .- 1079-7114. ; 120:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The CDF and D0 experiments at the Fermilab Tevatron have measured the asymmetry between yields of forward- and backward-produced top and antitop quarks based on their rapidity difference and the asymmetry between their decay leptons. These measurements use the full data sets collected in proton-antiproton collisions at a center-of-mass energy of root s = 1.96 TeV. We report the results of combinations of the inclusive asymmetries and their differential dependencies on relevant kinematic quantities. The combined inclusive asymmetry is A(FB)(t (t) over bar) = 0.128 +/- 0.025. The combined inclusive and differential asymmetries are consistent with recent standard model predictions.
  •  
3.
  • Aaltonen, T., et al. (författare)
  • Tevatron Constraints on Models of the Higgs Boson with Exotic Spin and Parity Using Decays to Bottom-Antibottom Quark Pairs
  • 2015
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 114:15
  • Tidskriftsartikel (refereegranskat)abstract
    • Combined constraints from the CDF and D0 Collaborations on models of the Higgs boson with exotic spin J and parity P are presented and compared with results obtained assuming the standard model value J(P) = 0(+). Both collaborations analyzed approximately 10 fb(-1) of proton-antiproton collisions with a center-of-mass energy of 1.96 TeV collected at the Fermilab Tevatron. Two models predicting exotic Higgs bosons with J(P) = 0(-) and J(P) = 2(+) are tested. The kinematic properties of exotic Higgs boson production in association with a vector boson differ from those predicted for the standard model Higgs boson. Upper limits at the 95% credibility level on the production rates of the exotic Higgs bosons, expressed as fractions of the standard model Higgs boson production rate, are set at 0.36 for both the J(P) = 0(-) hypothesis and the J(P) = 2(+) hypothesis. If the production rate times the branching ratio to a bottom-antibottom pair is the same as that predicted for the standard model Higgs boson, then the exotic bosons are excluded with significances of 5.0 standard deviations and 4.9 standard deviations for the J(P) = 0(-) and J(P) = 2(+) hypotheses, respectively.
  •  
4.
  • Noguchi, S, et al. (författare)
  • FANTOM5 CAGE profiles of human and mouse samples
  • 2017
  • Ingår i: Scientific data. - : Springer Science and Business Media LLC. - 2052-4463. ; 4, s. 170112-
  • Tidskriftsartikel (refereegranskat)abstract
    • In the FANTOM5 project, transcription initiation events across the human and mouse genomes were mapped at a single base-pair resolution and their frequencies were monitored by CAGE (Cap Analysis of Gene Expression) coupled with single-molecule sequencing. Approximately three thousands of samples, consisting of a variety of primary cells, tissues, cell lines, and time series samples during cell activation and development, were subjected to a uniform pipeline of CAGE data production. The analysis pipeline started by measuring RNA extracts to assess their quality, and continued to CAGE library production by using a robotic or a manual workflow, single molecule sequencing, and computational processing to generate frequencies of transcription initiation. Resulting data represents the consequence of transcriptional regulation in each analyzed state of mammalian cells. Non-overlapping peaks over the CAGE profiles, approximately 200,000 and 150,000 peaks for the human and mouse genomes, were identified and annotated to provide precise location of known promoters as well as novel ones, and to quantify their activities.
  •  
5.
  • Bonfiglio, F., et al. (författare)
  • A meta-analysis of reflux genome-wide association studies in 6750 Northern Europeans from the general population
  • 2017
  • Ingår i: Neurogastroenterology and Motility. - : Wiley. - 1350-1925 .- 1365-2982. ; 29:2
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundGastroesophageal reflux disease (GERD), the regurgitation of gastric acids often accompanied by heartburn, affects up to 20% of the general population. Genetic predisposition is suspected from twin and family studies but gene-hunting efforts have so far been scarce and no conclusive genome-wide study has been reported. We exploited data available from general population samples, and studied self-reported reflux symptoms in relation to genome-wide single nucleotide polymorphism (SNP) genotypes. MethodsWe performed a GWAS meta-analysis of three independent population-based cohorts from Sweden, Finland, and UK. GERD cases (n=2247) and asymptomatic controls (n=4503) were identified using questionnaire-derived symptom data. Upon stringent quality controls, genotype data for more than 2.5M markers were used for association testing. Bioinformatic characterization of genomic regions associated with GERD included gene-set enrichment analysis (GSEA), in silico prediction of genetic risk effects on gene expression, and computational analysis of drug-induced gene expression signatures using Connectivity Map (cMap). Key resultsWe identified 30 GERD suggestive risk loci (P5x10(-5)), with concordant risk effects in all cohorts, and predicted functional effects on gene expression in relevant tissues. GSEA revealed involvement of GERD risk genes in biological processes associated with the regulation of ion channel and cell adhesion. From cMap analysis, omeprazole had significant effects on GERD risk gene expression, while antituberculosis and anti-inflammatory drugs scored highest among the repurposed compounds. ConclusionsWe report a large-scale genetic study of GERD, and highlight genes and pathways that contribute to further our understanding of its pathogenesis and therapeutic opportunities.
  •  
6.
  • Stefanini, M., et al. (författare)
  • Patient-reported outcomes and aesthetic evaluation of root coverage procedures: a 12-month follow-up of a randomized controlled clinical trial
  • 2016
  • Ingår i: Journal of Clinical Periodontology. - : Wiley. - 0303-6979. ; 43:12, s. 1132-1141
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: To assess patient-reported outcome measures (PROMs), aesthetics and stability of root coverage procedures from a previous 6-month RCT after 1year. Material & Methods: Forty-five patients (90 recessions) had received a coronally advanced flap (CAF=control) only or a xenogeneic collagen matrix in addition (CAF+CMX=test). Visual analogue scales (VAS) and questionnaires were used for PROMs and the root coverage aesthetic score (RES) for professional aesthetic evaluations. Results: VAS scores (patient satisfaction) amounted to 8.58±1.86 (test) versus 8.38±2.46 (control). Six patients preferred CAF+CMX concerning surgical procedure and aesthetics, six preferred CAF and 29 were equally satisfied. RES was 7.85±2.42 for the test group versus 7.34±2.90 for the controls. Root coverage (RC) was 76.28% for test and 75.05% for control defects. The mean increase in keratinized tissue width was higher in test (from 1.97 to 3.02mm) than in controls (from 2.00 to 2.64 mm) (p=0.0413). Likewise, test sites showed more gain in gingival thickness (0.52mm) than control sites (0.27mm) (p=0.0023). Compared to 6months, clinical outcomes were stable. Conclusions: Results for PROMs, RES and RC did not significantly differ between treatment groups. Thickness and width of keratinized tissue were enhanced following CAF+CMX compared to CAF alone. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd
  •  
7.
  • Checchi, V., et al. (författare)
  • Wide diameter immediate post-extractive implants vs delayed placement of normal-diameter implants in preserved sockets in the molar region: 1-year postloading outcome of a randomised controlled trial
  • 2017
  • Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 10:3, s. 263-278
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare the effectiveness of 6.0 to 8.0 mm-wide diameter implants, placed immediately after tooth extraction, with conventional 4.0 or 5.0 mm diameter implants placed in a preserved socket after a 4-month period of healing in the molar region. Materials and Methods: Just after extraction of one or two molar teeth, and with no vertical loss of the buccal bone in relation to the palatal wall, 100 patients requiring immediate post-extractive implants were randomly allocated to immediate placement of one or two 6.0 to 8.0 mm-wide diameter implants (immediate group; 50 patients) or for socket preservation using a porcine bone substitute covered by a resorbable collagen barrier (delayed group; 50 patients), according to a parallel group design in one centre. Bone-to-implant gaps were filled with autogenous bone retrieved with a trephine drill used to prepare the implant sites for the immediate wide diameter post-extractive implants. Four months after socket preservation, one to two 4.0 or 5.0 mm-wide delayed implants were placed. Implants were loaded 4 months after placement with fixed provisional restorations in acrylic, and replaced after 4 months by fixed, definitive, metal-ceramic restorations. Patients were followed to 1 year after loading. Outcome measures were: implant failures, complications, aesthetics assessed using the pink esthetic score (PES), peri-implant marginal bone level changes, patient satisfaction, number of appointments and surgical interventions recorded, when possible, by blinded assessors. Results: Three patients dropped out 1 year after loading from the immediate group vs six from the delayed group. Five implants out of 47 failed in the immediate group (10.6%) vs two out 44 (4.6%) in the delayed group, the difference being not statistically significant (difference in proportion = 6.0%, 95% CI: -8.8% to 20.8%, P = 0.436). In the immediate group 10 patients were affected by 10 complications, while in the delayed group four patients were affected by four complications. The difference was not statistically significant (difference in proportion = 12%, 95% CI: -2% to 26%, P = 0.084). At delivery of the definitive prostheses, 4 months after loading, the mean total PES score was 9.65 ± 1.62 and 10.44 ± 1.47 in the immediate and delayed groups, respectively. At 1 year after loading, the mean total PES score was 9.71 ± 2.71 and 10.86 ± 1.37 in the immediate and delayed groups, respectively. The Total PES score was statistically significantly better at delayed implants both at 4 months (mean difference = 0.79; 95% CI: 0.05 to 1.53; P = 0.03) and at 1 year (mean difference = 1.15; 95% CI: 0.13 to 2.17; P = 0.02). Marginal bone levels at implant insertion (after bone grafting) were 0.04 mm for immediate and 0.11 mm for delayed implants, which was statistically significantly different (mean difference = 0.07; 95% CI: 0.02 to 0.12; P < 0.0001). One year after loading, patients in the immediate group lost on average 1.06 mm and those from the delayed group 0.63 mm, the difference being statistically significant (mean difference = 0.43 mm; 95% CI: 0.15 to 0.61; P < 0.0001). All patients were fully or partially satisfied both for function and aesthetics, and would undergo the same procedure again both at 4 months and 1 year after loading. Patients from the immediate group required on average 7.48 ± 1.45 visits to the clinician and 2.14 ± 0.49 surgical interventions and to have their definitive prostheses delivered vs 10.30 ± 0.99 visits and 3.08 ± 0.40 surgical interventions for the delayed group, the difference being statistically significant (P < 0.001 for visits, and P < 0.001 for surgical interventions). Conclusions: Preliminary 1 year follow-up data suggest that immediate placement of 6.0 to 8.0 mm wide diameter implants in molar extraction sockets yielded inferior aesthetic outcomes than ridge preservation and delayed placement of conventional 4.0 to 5.0 mm diameter implants. Conflict of interest statement: This trial was partially funded by the manufacturer of the implants evaluated in his investigation (MegaGen Implant Co, Gyeongbuk, South Korea). However, data belonged to the authors and in no way did the manufacturer interfere with the conduct of the trial or the publication of its results. © Quintessenz.
  •  
8.
  •  
9.
  • Felice, P., et al. (författare)
  • Immediate, immediate-delayed (6 weeks) and delayed (4 months) post-extractive single implants: 4-month post-loading data from a randomised controlled trial
  • 2016
  • Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 9:3, s. 233-247
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare the clinical outcome of single implants placed immediately after tooth extraction with implants placed 6 weeks after tooth extraction (immediate-delayed placement), and with implants placed after 4 months of extraction and socket healing (delayed placement). Materials and methods: Two hundred and ten patients requiring a single implant-supported crown to replace a tooth to be extracted were randomised to receive immediate post-extractive implants (70 patients), immediate-delayed implants at 6 weeks (70 patients), and delayed implants after 4 months of healing (70 patients), according to a parallel group design. When needed, patients of the immediate and immediate-delayed group had the socket grafted with a bone substitute and covered with a resorbable membrane at implant placement. Sockets randomised to delayed implants were grafted in the same manner if poorly preserved or in the aesthetic areas (from second upper to second upper premolars). Implants inserted with at least 25 Ncm torque were left to heal unloaded for 4 months, whereas those inserted with less than 25 Ncm were left to heal unloaded for 6 months. Temporary crowns were delivered and were to be replaced by definitive ones after 4 months. Outcome measures were crown and implant failures, complications, periimplant marginal bone level changes, aesthetics assessed using the pink esthetic score (PES) and patient satisfaction recorded by blinded assessors. Results: Three patients dropped out from the immediate, five from the immediate-delayed and six from the delayed group up to 4-months post-loading. Four implants (6.0%) failed in the immediate, four (6.2%) in the immediate-delayed and one (1.6%) from the delayed group (P (chi-square test) = 0.369). Apart from the crown failures due to implant losses, no other crown had to be remade. Five immediate, six immediate-delayed and three delayed implants were affected by one complication each (P (chi-square test) = 0.601). Mean peri-implant marginal bone loss after 4 months was -0.17 +/- 0.11 mm (95% CI: -0.20; -0.15) at immediate, -0.20 +/- 0.09 mm (95% CI: -0.23; -0.18) at immediate-delayed, and -0.24 +/- 0.12 mm (95% CI: -0.27; -0.21) at delayed placed implants (P (Kruskal Wallis test) = 0.006). At delivery of definitive crowns, 4 months after loading, the mean total aesthetic score was 12.48, 12.38 and 11.71 in the immediate, immediate-delayed and delayed groups, respectively (P (Kruskal Wallis test) < 0.001). All patients were fully satisfied with both function and aesthetics, and would undergo the same procedure again, with four exceptions (one from the immediate, one from the immediate-delayed and two from the delayed group), who were partially satisfied with the aesthetics (P = 0.785). Conclusions: No statistically significant differences for failures, complications and patient satisfaction were observed when placing single implants immediately, 6 weeks or four months after tooth extraction; nevertheless failures and complications were more frequent for immediate and immediate-delayed placed implants. Bone level changes were similar between the different procedures, but the aesthetics showed better results for immediate and immediate-delayed implants.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy