SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(de Vries A. C. H.) srt2:(2005-2009)"

Sökning: WFRF:(de Vries A. C. H.) > (2005-2009)

  • Resultat 1-10 av 37
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Abe, O, et al. (författare)
  • Effects of chemotherapy and hormonal therapy for early breast cancer on recurrence and 15-year survival: an overview of the randomised trials
  • 2005
  • Ingår i: The Lancet. - 1474-547X. ; 365:9472, s. 1687-1717
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Quinquennial overviews (1985-2000) of the randomised trials in early breast cancer have assessed the 5-year and 10-year effects of various systemic adjuvant therapies on breast cancer recurrence and survival. Here, we report the 10-year and 15-year effects. Methods Collaborative meta-analyses were undertaken of 194 unconfounded randomised trials of adjuvant chemotherapy or hormonal therapy that began by 1995. Many trials involved CMF (cyclophosphamide, methotrexate, fluorouracil), anthracycline-based combinations such as FAC (fluorouracil, doxombicin, cyclophosphamide) or FEC (fluorouracil, epirubicin, cyclophosphamide), tamoxifen, or ovarian suppression: none involved taxanes, trastuzumab, raloxifene, or modem aromatase inhibitors. Findings Allocation to about 6 months of anthracycline-based polychemotherapy (eg, with FAC or FEC) reduces the annual breast cancer death rate by about 38% (SE 5) for women younger than 50 years of age when diagnosed and by about 20% (SE 4) for those of age 50-69 years when diagnosed, largely irrespective of the use of tamoxifen and of oestrogen receptor (ER) status, nodal status, or other tumour characteristics. Such regimens are significantly (2p=0 . 0001 for recurrence, 2p<0 . 00001 for breast cancer mortality) more effective than CMF chemotherapy. Few women of age 70 years or older entered these chemotherapy trials. For ER-positive disease only, allocation to about 5 years of adjuvant tamoxifen reduces the annual breast cancer death rate by 31% (SE 3), largely irrespective of the use of chemotherapy and of age (<50, 50-69, &GE; 70 years), progesterone receptor status, or other tumour characteristics. 5 years is significantly (2p<0 . 00001 for recurrence, 2p=0 . 01 for breast cancer mortality) more effective than just 1-2 years of tamoxifen. For ER-positive tumours, the annual breast cancer mortality rates are similar during years 0-4 and 5-14, as are the proportional reductions in them by 5 years of tamoxifen, so the cumulative reduction in mortality is more than twice as big at 15 years as at 5 years after diagnosis. These results combine six meta-analyses: anthracycline-based versus no chemotherapy (8000 women); CMF-based versus no chemotherapy (14 000); anthracycline-based versus CMF-based chemotherapy (14 000); about 5 years of tamoxifen versus none (15 000); about 1-2 years of tamoxifen versus none (33 000); and about 5 years versus 1-2 years of tamoxifen (18 000). Finally, allocation to ovarian ablation or suppression (8000 women) also significantly reduces breast cancer mortality, but appears to do so only in the absence of other systemic treatments. For middle-aged women with ER-positive disease (the commonest type of breast cancer), the breast cancer mortality rate throughout the next 15 years would be approximately halved by 6 months of anthracycline-based chemotherapy (with a combination such as FAC or FEC) followed by 5 years of adjuvant tamoxifen. For, if mortality reductions of 38% (age <50 years) and 20% (age 50-69 years) from such chemotherapy were followed by a further reduction of 31% from tamoxifen in the risks that remain, the final mortality reductions would be 57% and 45%, respectively (and, the trial results could well have been somewhat stronger if there had been full compliance with the allocated treatments). Overall survival would be comparably improved, since these treatments have relatively small effects on mortality from the aggregate of all other causes. Interpretation Some of the widely practicable adjuvant drug treatments that were being tested in the 1980s, which substantially reduced 5-year recurrence rates (but had somewhat less effect on 5-year mortality rates), also substantially reduce 15-year mortality rates. Further improvements in long-term survival could well be available from newer drugs, or better use of older drugs.
  •  
3.
  • Abbasi, R., et al. (författare)
  • The IceCube data acquisition system : Signal capture, digitization, and timestamping
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 601:3, s. 294-316
  • Tidskriftsartikel (refereegranskat)abstract
    • IceCube is a km-scale neutrino observatory under construction at the South Pole with sensors both in the deep ice (InIce) and on the surface (IceTop). The sensors, called Digital Optical Modules (DOMs). detect, digitize and timestamp the signals from optical Cherenkov-radiation photons. The DOM Main Board (MB) data acquisition subsystem is connected to the central DAQ in the IceCube Laboratory (ICL) by a single twisted copper wire-pair and transmits packetized data on demand. Time calibration is maintained throughout the array by regular transmission to the DOMs of precisely timed analog signals, synchronized to a central GPS-disciplined clock. The design goals and consequent features, functional capabilities, and initial performance of the DOM MB, and the operation of a combined array of DOMs as a system, are described here. Experience with the first InIce strings and the IceTop stations indicates that the system design and performance goals have been achieved. (c) 2009 Elsevier B.V. All rights reserved.
  •  
4.
  •  
5.
  • Abbasi, R., et al. (författare)
  • Solar energetic particle spectrum on 2006 December 13 determined by IceTop
  • 2008
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 689:1, s. L65-L68
  • Tidskriftsartikel (refereegranskat)abstract
    • On 2006 December 13 the IceTop air shower array at the South Pole detected a major solar particle event. By numerically simulating the response of the IceTop tanks, which are thick Cerenkov detectors with multiple thresholds deployed at high altitude with no geomagnetic cutoff, we determined the particle energy spectrum in the energy range 0.6-7.6 GeV. This is the first such spectral measurement using a single instrument with a well-defined viewing direction. We compare the IceTop spectrum and its time evolution with previously published results and outline plans for improved resolution of future solar particle spectra.
  •  
6.
  • Ackermann, M., et al. (författare)
  • Search for ultra-high-energy neutrinos with amanda-II
  • 2008
  • Ingår i: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 675:2, s. 1014-1024
  • Tidskriftsartikel (refereegranskat)abstract
    • A search for diffuse neutrinos with energies in excess of 10(5) GeV is conducted with AMANDA-II data recorded between 2000 and 2002. Above 10(7) GeV, the Earth is essentially opaque to neutrinos. This fact, combined with the limited overburden of the AMANDA-II detector ( roughly 1.5 km), concentrates these ultra-high-energy neutrinos at the horizon. The primary background for this analysis is bundles of downgoing, high-energy muons from the interaction of cosmic rays in the atmosphere. No statistically significant excess above the expected background is seen in the data, and an upper limit is set on the diffuse all-flavor neutrino flux of E-2 Phi(90%CL) < 2.7x10(-7) GeV cm(-2) s(-1) sr(-1) valid over the energy range of 2x10(5) to 10(9) GeV. A number of models that predict neutrino fluxes from active galactic nuclei are excluded at the 90% confidence level.
  •  
7.
  • Achterberg, A., et al. (författare)
  • Detection of atmospheric muon neutrinos with the IceCube 9-string detector
  • 2007
  • Ingår i: Physical Review D - Particles, Fields, Gravitation and Cosmology. - 1550-7998. ; 76:2, s. 027101-
  • Tidskriftsartikel (refereegranskat)abstract
    • The IceCube neutrino detector is a cubic kilometer TeV to PeV neutrino detector under construction at the geographic South Pole. The dominant population of neutrinos detected in IceCube is due to meson decay in cosmic-ray air showers. These atmospheric neutrinos are relatively well understood and serve as a calibration and verification tool for the new detector. In 2006, the detector was approximately 10% completed, and we report on data acquired from the detector in this configuration. We observe an atmospheric neutrino signal consistent with expectations, demonstrating that the IceCube detector is capable of identifying neutrino events. In the first 137.4 days of live time, 234 neutrino candidates were selected with an expectation of 211 +/- 76.1(syst)+/- 14.5(stat) events from atmospheric neutrinos.
  •  
8.
  • Abbasi, R., et al. (författare)
  • SEARCH FOR HIGH-ENERGY MUON NEUTRINOS FROM THE "NAKED-EYE" GRB 080319B WITH THE IceCube NEUTRINO TELESCOPE
  • 2009
  • Ingår i: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 701:2, s. 1721-1731
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on a search with the IceCube detector for high-energy muon neutrinos from GRB 080319B, one of the brightest gamma-ray bursts (GRBs) ever observed. The fireball model predicts that a mean of 0.1 events should be detected by IceCube for a bulk Lorentz boost of the jet of 300. In both the direct on-time window of 66 s and an extended window of about 300 s around the GRB, no excess was found above background. The 90% CL upper limit on the number of track-like events from the GRB is 2.7, corresponding to a muon neutrino fluence limit of 9.5 x 10(-3) erg cm(-2) in the energy range between 120 TeV and 2.2 PeV, which contains 90% of the expected events.
  •  
9.
  • Abbasi, R., et al. (författare)
  • Search for point sources of high energy neutrinos with final data from AMANDA-II
  • 2009
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 79, s. 062001-
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a search for point sources of high energy neutrinos using 3.8 yr of data recorded by AMANDA-II during 2000-2006. After reconstructing muon tracks and applying selection criteria designed to optimally retain neutrino-induced events originating in the northern sky, we arrive at a sample of 6595 candidate events, predominantly from atmospheric neutrinos with primary energy 100 GeV to 8 TeV. Our search of this sample reveals no indications of a neutrino point source. We place the most stringent limits to date on E(-2) neutrino fluxes from points in the northern sky, with an average upper limit of E(2)Phi(nu mu)+nu(tau)<= 5.2x10(-11) TeV cm(-2) s(-1) on the sum of nu(mu) and nu(tau) fluxes, assumed equal, over the energy range from 1.9 TeV to 2.5 PeV.
  •  
10.
  • Ageron, M., et al. (författare)
  • The ANTARES optical beacon system
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 578:3, s. 498-509
  • Tidskriftsartikel (refereegranskat)abstract
    • ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 37

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy